Beijing Jinzhengmao Technology Co., Ltd
Home>Products>Jinzhengmao Platinum Resistance Temperature Sensor
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13601091939
  • Address
    No. 125, Building 21, No. 8 Jijiamiao, Fengtai District, Beijing
Contact Now
Jinzhengmao Platinum Resistance Temperature Sensor
The Jinzhengmao Platinum Resistance Temperature Sensor Laboratory Equipment is an excellent choice for measuring and controlling temperature between 7
Product details

PT100Platinum resistance temperature sensor

Jinzhengmao Platinum Resistance Temperature Sensor Laboratory equipmentFor those requiring 70Karrive500KIn situations where temperature is measured and controlled,PT100Platinum resistance thermometer is an excellent choice. Within this temperature range, platinum resistance thermometers have good repeatability and almost constant sensitivity. Within the allowable range of error(1Platinum resistance thermometers can also be applied in magnetic fields and radiation environments.

Jinzhengmao Platinum Resistance Temperature Sensor Laboratory equipment70KThe above platinum resistance thermometers have a universal standard curve, which makes them highly interchangeable. The thin film platinum resistor provided by Jinzhengmao has a smaller size, shorter response time, and a wider range of applications.

characteristic

※ 40KThe above are less affected by magnetic fields;

Extremely minimally affected by ionizing radiation;v

※ Provide two-point, three-point, or multi-point calibration.

parameter

※ Temperature range: 14K~873K

Standard curve:IEC 751

Recommended excitation current:1mA

Recommended dissipated power under incentive:100μW@273K

Sensitivity: Follow PT100Typical sensitivity curve

Response time:1.5S@77K10S@273K

Radiation impact: Can be used in a radiation environment

Magnetic field influence: not recommended40KUsed in the following magnetic field environment

Repeatability:±ten mK@77K(Through)100order300Karrive77KComing from the thermal shock test)


Typical characteristic curve











Calibration accuracy:

20-77K

77-305K

305 -400K

400-475K

475-500K

2P

±0.25K

±0.9K

±1.3K

±1.4K

3P

±0.1K

±1.4K

20L

±0.1K

±0.1K

20H

±0.1K

±0.1K

±0.1K

±0.1K

±0.1K

70L

±0.1K

70H

±0.1K

±0.1K

±0.1K

±0.1K

2P77Kand273Kcalibration3P77K273Kand475Kcalibration

Packaging form and size (packaging reference)DT640Package size)

Selection steps refer toDT640Selection steps are carried out


Physical dimensions






Lead wire:2root

Quality:17mg

Packaging form:Thin film platinum encapsulated within ceramic chips




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!