Kestrel 3500DT agricultural handheld meteorological instrument, Chengdu anemometer, meteorological instrument manufacturer
Purpose:When spraying agricultural chemicals on crops, it is crucial to ensure their safety and effectiveness by measuring the relative humidity, wind speed, and direction of the air. Many places have stipulated the maximum wind speed for agricultural chemical spraying, in order to minimize the drift of agricultural chemical spraying. Under hot and dry conditions, agricultural chemicals may evaporate into the air instead of onto your crops. However, you can reduce this evaporation by selecting an appropriate nozzle and increasing the size of the spray droplets.
The Kestrel 3500DT agricultural handheld meteorological instrument integrates Delta T calculation, which can quickly provide ideal agricultural chemical spraying environment values based on wet bulb temperature and dry bulb temperature. For example, it is not recommended to spray agricultural chemicals above a Delta T value of 10, and a value of 2-8 is the ideal range for agricultural chemical spraying.
The wet bulb temperature calculation of Kestrel 3500DT agricultural handheld meteorological instrument adopts pressure calibration to ensure accuracy in low-pressure environments. Delta T monitoring is very important in high-altitude areas and dry environments.
Kestrel 3500DT agricultural handheld meteorological instrument, Chengdu anemometer, meteorological instrument manufacturer? Sensor Technical Specifications:
wind speed | |
accuracy |
Better than ± 3% of the reading |
resolution |
0.1 meters per second |
Specification range |
0.6~40.0 meters per second |
scope of work |
0.6~60.0 meters per second |
air temperature | |
accuracy |
±0.5℃ |
resolution |
0.1℃ |
Specification range |
-29.0~+70.0℃ |
scope of work |
-10.0~+55.0℃ |
relative humidity | |
accuracy |
±3%RH |
resolution |
0.1%RH |
Specification range |
5.0~95.0% RH non condensing |
scope of work |
0.0~100%RH |
pressure | |
accuracy |
±1.0 mBar |
resolution |
0.1 mBar |
Specification range |
300.0~1100.0 mBar(0.0~+85.0℃) |
scope of work |
10.0~1654.7 mBar(-10.0~+55.0℃) |
Parameter specifications for calculation:
altitude | |
accuracy |
Typical ± 7.2 meters, maximum ± 14.7 meters |
resolution |
1 meter |
Specification range |
Typical 750~1100 mBar, maximum 300~750 mBar |
Calculate sensors |
pressure |
air pressure | |
accuracy |
±2.4 mBar |
resolution |
0.1 mBar |
Specification range |
Reference calculation sensor range |
Calculate sensors |
Pressure and user input (reference altitude) |
Delta T | |
accuracy |
±1.8℃ |
resolution |
0.1℃ |
Specification range |
Reference calculation sensor range |
Calculate sensors |
Air temperature, relative humidity, and pressure |
dew point | |
accuracy |
±1.9℃ |
resolution |
0.1℃ |
Specification range |
Reference calculation sensor range |
Calculate sensors |
Air temperature and relative humidity |
Wet bulb thermometer hygrometer | |
accuracy |
±1.8℃ |
resolution |
0.1℃ |
Specification range |
Reference calculation sensor range |
Calculate sensors |
Air temperature, relative humidity, and pressure |
Other technical specifications of the host:
display |
LCD display screen |
Background light |
With green background light, it can be manually turned on and automatically turned off |
response time |
1 second (relative humidity of 10 seconds) |
Display update time |
1 second |
clock |
Real time clock hours and minutes |
Automatic shutdown |
Automatic shutdown after about 45 minutes of inactivity |
certificate |
CE certification |
battery |
1 CR2032 alkaline battery, approximately 300 hours of usage time |
protection grade |
IP67 |
operation temperature |
-10~+55℃ |
storage temperature |
-30~+60℃ |
size |
12.2 × 4.8 × 2.8 millimeters |
weight |
102 grams |
Optional attachments:
name |
Application Description |
illustration |
baby tripod |
The host can be placed on a triangular bracket to achieve unmanned monitoring of fixed points. The maximum height is 25 centimeters. |
|
Tripod clamp |
Used to secure the host to a tripod. |
|
Backup wind turbine |
Used for replacing damaged wind turbines. |
|
Relative humidity calibration kit |
To improve the accuracy of the host's relative humidity probe, the relative humidity sensor generally needs to be recalibrated every 2 years. |
|
North compass |
Used to determine direction. |
Origin: United States