Kestrel 3500DT agricultural handheld meteorological instrument, Chengdu anemometer, meteorological instrument manufacturer

Purpose:When spraying agricultural chemicals on crops, it is crucial to ensure their safety and effectiveness by measuring the relative humidity, wind speed, and direction of the air. Many places have stipulated the maximum wind speed for agricultural chemical spraying, in order to minimize the drift of agricultural chemical spraying. Under hot and dry conditions, agricultural chemicals may evaporate into the air instead of onto your crops. However, you can reduce this evaporation by selecting an appropriate nozzle and increasing the size of the spray droplets.
The Kestrel 3500DT agricultural handheld meteorological instrument integrates Delta T calculation, which can quickly provide ideal agricultural chemical spraying environment values based on wet bulb temperature and dry bulb temperature. For example, it is not recommended to spray agricultural chemicals above a Delta T value of 10, and a value of 2-8 is the ideal range for agricultural chemical spraying.
The wet bulb temperature calculation of Kestrel 3500DT agricultural handheld meteorological instrument adopts pressure calibration to ensure accuracy in low-pressure environments. Delta T monitoring is very important in high-altitude areas and dry environments.

Kestrel 3500DT agricultural handheld meteorological instrument, Chengdu anemometer, meteorological instrument manufacturer? Sensor Technical Specifications:

wind speed

accuracy

Better than ± 3% of the reading

resolution

0.1 meters per second

Specification range

0.6~40.0 meters per second

scope of work

0.6~60.0 meters per second

air temperature

accuracy

±0.5℃

resolution

0.1℃

Specification range

-29.0~+70.0℃

scope of work

-10.0~+55.0℃

relative humidity

accuracy

±3%RH

resolution

0.1%RH

Specification range

5.0~95.0% RH non condensing

scope of work

0.0~100%RH

pressure

accuracy

±1.0 mBar

resolution

0.1 mBar

Specification range

300.0~1100.0 mBar(0.0~+85.0℃)

scope of work

10.0~1654.7 mBar(-10.0~+55.0℃)

Parameter specifications for calculation:

altitude

accuracy

Typical ± 7.2 meters, maximum ± 14.7 meters

resolution

1 meter

Specification range

Typical 750~1100 mBar, maximum 300~750 mBar

Calculate sensors

pressure

air pressure

accuracy

±2.4 mBar

resolution

0.1 mBar

Specification range

Reference calculation sensor range

Calculate sensors

Pressure and user input (reference altitude)

Delta T

accuracy

±1.8℃

resolution

0.1℃

Specification range

Reference calculation sensor range

Calculate sensors

Air temperature, relative humidity, and pressure

dew point

accuracy

±1.9℃

resolution

0.1℃

Specification range

Reference calculation sensor range

Calculate sensors

Air temperature and relative humidity

Wet bulb thermometer hygrometer

accuracy

±1.8℃

resolution

0.1℃

Specification range

Reference calculation sensor range

Calculate sensors

Air temperature, relative humidity, and pressure

Other technical specifications of the host:

display

LCD display screen

Background light

With green background light, it can be manually turned on and automatically turned off

response time

1 second (relative humidity of 10 seconds)

Display update time

1 second

clock

Real time clock hours and minutes

Automatic shutdown

Automatic shutdown after about 45 minutes of inactivity

certificate

CE certification

battery

1 CR2032 alkaline battery, approximately 300 hours of usage time

protection grade

IP67

operation temperature

-10~+55℃

storage temperature

-30~+60℃

size

12.2 × 4.8 × 2.8 millimeters

weight

102 grams


Optional attachments:

name

Application Description

illustration

baby tripod

The host can be placed on a triangular bracket to achieve unmanned monitoring of fixed points. The maximum height is 25 centimeters.

Tripod clamp

Used to secure the host to a tripod.

Backup wind turbine

Used for replacing damaged wind turbines.

Relative humidity calibration kit

To improve the accuracy of the host's relative humidity probe, the relative humidity sensor generally needs to be recalibrated every 2 years.

North compass

Used to determine direction.


Origin: United States