Korean Jieaote Wet Heat Sterilization PotSterilization pot (vertical)
A microprocessor controller with reliable safety features ensures sterilization temperature.
model: ST-50G
Korean Jieaote Wet Heat Sterilization PotPerformance characteristics
The microprocessor controller and temperature correction function provide users with high-precision temperature control.
-Sterilization temperature between 110~123 ° C
-The melting temperature is between 60-100 ° C(Solubility of solid agar medium)Automatic disinfection system for unmanned operation.
-Heating>Safety Check>Disinfection>Safety Disinfection>Exhaust>EndThe operation method is simple and versatile.
-Please refer to the table below for standard mode and program mode.Temperature calibration function.
Korean Jieaote Wet Heat Sterilization PotEasy to operate
The independent control display, disinfection program display, and pressure gauge can facilitate the operation of the monitoring system.
- VFD(Fluorescent display)The screen can vividly display temperature and pressure(Optional)Timed and early warning alerts.
-The sterilization process can be displayed by LED lights.
-The front pressure gauge can conveniently read the pressure.The vertical high-pressure sterilization pot loads samples from the top and is suitable for sterilizing large capacity samples.
-Baskets that can stack more than 2 layers inside the cavity can effectively utilize space.Easy to maintain
-The sterilization chamber with stainless steel structure is very corrosion-resistant.
-Easy to replace silicone sealing rings.Data logger(Optional).
-The 6-point recorder can accurately record data.
Korean Jieaote Wet Heat Sterilization PotSafety features
Mechanical safety device.
-Current overload protection.
-Over temperature protection, automatically cuts off power.
-Overpressure protection can be achieved through automatic or manual safety valves.Security alarm system.
-Over temperature alarm.
-Low temperature alarm.
-Low heat alarm.
-Low heat alarm: If the sterilization temperature or dissolution temperature is not reached within a certain period of time, the equipment will sound and light an alarm and stop working.
-Sterilization failure alarm: When the equipment suddenly stops working during the sterilization process, the sound and light alarm will remind attention.The use of a low thermal conductivity plastic side opening lid cover can effectively prevent experimental personnel from getting burned.
model | ST-50G | ||||
---|---|---|---|---|---|
controller | Microfabrication PID Control | ||||
Chamber volume(L / cu ft) | 50 / 1.8 | 65 / 2.3 | 85 / 3.0 | 105 / 3.7 | |
Temperature1) | Sterilization temperature(℃/ ℉) | 110 to 123 / 198 to 221.4 | |||
Solubility(℃ / ℉) | 60 to 100 / 108 to 180 | ||||
pressure | Sterilization at 121 ℃(kg/cm2) | 1.1 to 1.2 | |||
Simulated measurement range(Mpa) | - 0.1 to 0.6 | ||||
Security performance | Over temperature protection/pressure safety valve/overcurrent protection | ||||
Warning Alert(High temperature/low temperature/low heat/sterilization failure/low liquid level) | |||||
Timer function | 0 to 999 minutes | ||||
size | Number of baskets(Standard/Maximum Quantity) | 2 / 2 | 2 / 2 | 2 / 2 | 2 / 2 |
Basket load(Kg / lbs) | 10 / 22.0 | ||||
Basket(?xH) (mm / inch) | 380x180 / 14.9x7.1 | 380x230 / 14.9x9.1 | 380x330 / 14.9x13.0 | 380x405 / 14.9x15.9 | |
Inside the cavity(WxH) (mm / inch) | 400x458 / 15.7x18.0 | 400x558 / 15.7x21.9 | 400x758 / 15.7x29.8 | 400x908 / 15.7x35.7 | |
External dimensions(W×D×H) (mm / inch) |
624x672x870 / 24.6x26.5x34.2 |
624x672x971 / 24.6x26.5x38.2 |
624x672x1083 / 24.6x26.5x42.6 |
624x672x1233 / 24.6x26.5x48.5 |
|
External dimensions, with drainage bucket (W×D×H) (mm / inch) |
722x672x870 / 28.4x26.5x34.2 |
722x672x971 / 28.4x26.5x38.2 |
722x672x1083 / 28.4x26.5x42.6 |
722x672x1233 / 28.4x26.5x18.5 |
|
Net weight(Kg / lbs) | 94.5 / 208.3 | 99.5 / 219.4 | 104 / 229.3 | 110 / 242.5 | |
Power requirements(230V, 50 / 60 Hz) | 14.3A | 14.3A | 14.3A | 21.3A | |
Item number | AAHL1015K | AAHL1025K | AAHL1035K | AAHL1045K |
1) All parameters comply with EN 554/BS EN 285:1997 requirements
*Applicable environmental requirements: temperature(5-40℃)Relative humidity(10-80%).