satisfyIEC60695-2-10/11/12/13、IEC60884-1、GB2099.1、IEC60335-1、GB4706.1、VDE、GB/T5169.10Waiting for standards
Under fault or overload conditions, components or parts may reach excessively high temperatures or ignite nearby parts. The hot wire test simulates the electric heating element or overloadResistance and other forms of heat
The thermal stress caused by a source or ignition source in a short period of time can be evaluated for fire hazard using simulation technology, which is applicable to electrical and electronic products, components, and household appliancesPlastic and non plastic materials used for components
Metal insulation material parts such as switch housings, relay sockets, etcSpecify the material(Ni80/Cr20)Electric heating wire with the same shape(Φ4 mmHeat the nickel chromium wire with high current until the test is conducted
Temperature(550 ℃ ~ 960 ℃1minAfterwards,Under regulated pressure(1.0N)Vertical burning test sample30sDetermine the electrical conductivity based on whether the test sample and substrate ignite or hold on for a certain period of time
The fire hazard of sub equipment products; measureIgnition and ignition temperature of solid insulation materials and other solid combustible materials(GWIT)Flammability and Flammability Index(GWFI).
Technical specifications: