LN-5 (stainless steel strip) plastic coated waterproof typeFlexible metal wire protection sleeve
LN-5 (NCr) PVC Covered Type
LN-5 (stainless steel strip) plastic coated waterproof flexible metal wire protective sleeve, wrapped with a layer of flexible polyvinyl chloride (PVC) protective layer on the surface of LN-4B metal sleeve using a special method. This product not only has the characteristics of LN-4B, but also has excellent water resistance, corrosion resistance, and chemical resistance. It can be used as various exposed and concealed pre buried and directly buried pipes, and can also replace ground trunking wiring pipes.
LN-5 (Ncr) packet-Prica waterproof plastic casing to protect metal wires, use special methods in
LN-4B metal casing surface, Flexibility is a good coating layer of soft polyvinyl chloride (PVC) protective layer.
Except LN-4B characteristics of the product, there are excellent water resistance, corrosion resistance, che mical resistance ,for all that Dark embedded and buried piping ,wiring can be replaced with ground trough ,etc.
LN-5 specification table
|
Specifications Catalogue
|
inner diameter I.D.
|
outer diameter O.D.
|
Outer diameter tolerance O.D。 Tolerance
|
Ethylene layer thickness Thickness Of PVC(min)
|
Length of each roll Lengt/roll
|
Corresponding specifications of steel pipes Relevant Conduit
|
conduitCorresponding specifications Relevant conduit for electric
|
||
|
Number
|
mm
|
mm
|
mm
|
mm
|
m
|
mm
|
"
|
mm
|
"
|
|
12#
|
11.4
|
17.7
|
±0.2
|
0.6
|
50
|
8
|
1/4"
|
13
|
1/2"
|
|
15#
|
14.1
|
20.6
|
±0.2
|
0.6
|
50
|
10
|
3/8"
|
16
|
5/8"
|
|
17#
|
16.6
|
23.1
|
±0.2
|
0.6
|
50
|
15
|
1/2"
|
19
|
3/4"
|
|
24#
|
23.8
|
30.4
|
±0.2
|
0.6
|
25
|
20
|
3/4”
|
25
|
1"
|
|
30#
|
29.3
|
36.5
|
±0.2
|
0.6
|
25
|
25
|
1 ”
|
32
|
11/4"
|
|
38#
|
37.1
|
44.9
|
±0.4
|
0.6
|
25
|
32
|
11/4"
|
38
|
11/2"
|
|
50#
|
49.1
|
56.9
|
±0.4
|
0.8
|
25
|
40
|
11/2"
|
51
|
2"
|
|
63#
|
62.6
|
71.5
|
±0.6
|
0.8
|
10
|
50
|
2,
|
64
|
21/2"
|
|
76#
|
76.0
|
85.3
|
±0.6
|
0.8
|
10
|
70
|
21/2"
|
76
|
3"
|
|
83#
|
81.0
|
90.9
|
±0.8
|
1.0
|
10
|
80
|
3,
|
|
|
|
101#
|
100.2
|
110.1
|
±0.8
|
1.0
|
5
|
100
|
4"
|
|
|
According to JG/T3053-1998 standard
1. Each roll of casing 12 #, 15 #, and 17 # is allowed to have two joints (three pieces), and the minimum length of the short end should not be less than 8M. Each roll of casing 24 #, 30 #, 38 #, and 50 # is allowed to have one joint (two pieces), and the minimum length of the short end should not be less than 5M.
2. The flexible metal wire protection sleeve corresponds to the steel pipe according to the inner diameter size.
standards byJG/T3053—1998
1.casing 12#,15#.NO.170utburst allowed per two joints(3)A short,the first part at least should not be less than 8M 24#,30#,38#,50#peraIlow a joint (KAN)short head at least part of not less than 5M.
2.Prica metal casing to protect wiring in accordance with the diameter of pipe size counterparts.