LN-5Z (stainless steel strip) waterproof and flame-retardant flexible metal wire protection sleeve
LN-5Z (NCr) Water Proof&Prevention Burning Type

LN-5Z (stainless steel strip) waterproof and flame-retardant flexible metal wire protection sleeve, with the same structural specifications as LN-5, made of high-quality temperature resistant and flame-retardant PVC with strong fire resistance. Suitable for indoor and outdoor power wire piping with high requirements for moisture and fire prevention. It can be used for open and concealed pre buried and directly buried piping in dry bridges, tunnels, shipbuilding, power plants, high-end buildings, etc. It can also replace ground trunking wiring pipes, etc.
LN-5Z (Ncr) and waterproof casing flame retardant protection Prica metal wires. LN-5 compliance with the same structure, temperature flame retardant PVC quality level, strength of fire,apply to indoor and outdoor fire damp demand for a higher power distribution control cable for bridges tunnels, shipbuilding plant that the high-grade construction, and buried secretly embedded in the piping wiring can be replaced with ground trough, etc
LN-5Z Standard Dimensions of LN-5Z PRICA PIPE
|
Specifications
Catalogue
Number
|
inner diameter
I.D。
|
outer diameter
O.D.
|
Outer diameter tolerance
O.D.
Tolerance
|
Ethylene layer thickness
ThicknessOf
PVC(min)
|
Length of each roll
Length/roll
|
Corresponding specifications of steel pipes
Relevant Conduit
|
Corresponding specifications of wire conduit
Relevant Conduit for
ElectricWire
|
||
|
|
mm
|
mm
|
mm
|
mm
|
m
|
mm
|
|
mm
|
|
|
12#
|
11.4
|
17.7
|
±0.2
|
0.6
|
50
|
8
|
1/4"
|
13
|
1/2"
|
|
15#
|
14.1
|
20.6
|
±0.2
|
0.6
|
50
|
10
|
3/8"
|
16
|
5/8"
|
|
17#
|
16.6
|
23.1
|
±0.2
|
0.6
|
50
|
15
|
1/2"
|
19
|
3/4"
|
|
24#
|
23.8
|
30.4
|
±0.2
|
0.6
|
25
|
20
|
3/4"
|
25
|
1"
|
|
30#
|
29.3
|
36.5
|
±0.2
|
0.6
|
25
|
25
|
1 "
|
32
|
11/4"
|
|
38#
|
37.1
|
44.9
|
±0.4
|
0.6
|
25
|
32
|
11/4"
|
38
|
11/2"
|
|
50#
|
49.1
|
56.9
|
±0.4
|
0.8
|
25
|
40
|
11/2”
|
51
|
2"
|
|
63#
|
62.6
|
71.5
|
±0.6
|
0.8
|
10
|
50
|
2"
|
64
|
21/2"
|
|
76#
|
76.0
|
85.3
|
±0.6
|
0.8
|
10
|
70
|
21/2"
|
76
|
3"
|
|
83#
|
81.0
|
90.9
|
±0.8
|
1.0
|
10
|
80
|
3"
|
|
|
|
101#
|
100.2
|
110.1
|
±0.8
|
1.0
|
5
|
100
|
4"
|
|
|
·
According to JG/T3053-1998 standard
Each roll of conduit 12 #, 15 #, and 17 # is allowed to have two joints (three pieces), and the minimum length of the short end should not be less than 8M. Each roll of conduit 30 #, 38 #, and 50 # is allowed to have one joint (two pieces), and the minimum length of the short end should not be less than 5M. 2. Flexible metal wire protection conduit and steel pipe should correspond to the inner diameter size.
Standards by JG/T3053-1998
1.casing 12#,15#.NO.170utburst allowed per two joints(3)A short,the first part at least should not be less than 8M.24#,30#,38#,50#peraIlow a joint (KAN)short head at least part of not less than 5M.2.Prica metal casing to protect wiring in accordance with the diameter of pipe size counterparts.