1.Observation range and sample size: The observation range is the range of the field of view, and the sample size can be larger than the range of the field of view. As long as the observed part can be placed in the field of view, it can be observed 2.Measurement unit: If the degree is in degrees, you can multiply it by a coefficient and convert it to nanometer values yourself | |||||||
order |
model |
Product Name |
fixed quantity ,qualitative |
Measurement unit 1.Angle, dial 2.optical path difference (Nano) |
measuring range In actual measurement, the range of 0-150nm is sufficient |
Read the most Small units |
accuracy |
1 |
WYL-2 |
stress meter |
qualitative |
0-560nm |
Look with your eyes, compare the color chart, estimate the stress range |
||
2 |
WYL-3 |
Dial stress gauge |
fixed quantity |
angle |
0-280nm |
0.2nm |
5nm |
3 |
WYL-S |
stress meter Imaging system |
fixed quantity |
Optical path difference (digital display) |
0-150nm |
0.2nm |
5nm,Can connect to a computer to output images |
4 |
LZY-150 |
Vertical stress meter (Digital display) |
fixed quantity |
Optical path difference (digital display) |
0-150nm |
0.1nm |
4nm |
5 |
WZY-250A |
Horizontal stress gauge (Digital display) |
fixed quantity |
Optical path difference (digital display) |
0-150nm |
1nm |
4nm |
6 |
WZY-250 |
Horizontal stress gauge |
fixed quantity |
angle |
0-150nm |
1linear measure |
1linear measure |
7 |
SZY-150 |
Portable stress gauge |
qualitative |
0-150nm |
Look with your eyes, compare the color chart, estimate the stress range |
LZY-150.Stress gauge (digital display) The glass product stress tester is an instrument that uses the principle of polarized light interference to check the internal stress or crystal birefringence effect in glass. Due to the presence of sensitive color plates and the application of 1/4 waveplate compensation method, this instrument can not only qualitatively or semi quantitatively measure the internal stress of glass based on the interference color sequence in the polarization field, but also accurately and quantitatively measure the internal stress value of glass. Therefore, this instrument is suitable for optical instrument factories, glass factories, glass product factories, and laboratories to measure stress values of optical glass, glass products, and other optical materials.
Technical Parameter Instrument reading: 1 nanometer Measurement accuracy: (double fold range difference) 4 nanometers Polarization field diameter: 150 millimeters Polarizer rotation angle: 360 ° The maximum brightness of the light field shall not be less than 800 lux The maximum distance between the polarizer and the analyzer is 340mm |
1. Polarizer 2.1/4 waveplate 3. Wave plate conversion knob 4. Lift seat 5. Polarizing mirror 6. Light source box 7. Display window switch 8. Reset key 9. Lock the handwheel 10. Guiding rod 11. Switch 12. Display battery |