Liquid chlorine storage tank level gauge
Liquid chlorine storage tank level gauge
Product details

Liquid chlorine storage tank level gaugeThe indicator device is located on the outside or top of the tank to indicate and regulate the liquid level inside the tank. The sealing method can be equipped with a drain valve according to the needs. A type of control instrument that can withstand customized liquid level height with a connecting flange. The indicator is composed of magnetic color chips. When the magnetic float in the body tube rises with the liquid level, the color chips flip to display the liquid level height. Magnetic switches or remote transmitters can also be installed on the main body tube to output switch signals or analog signal signals. Suitable for high temperature, high pressure, corrosion-resistant and other places, it can be displayed on the spot and controlled over long distances. The body tube of the magnetic flap level gauge is made of seamless steel pipe, and the connecting pipe is welded with pull holes, with no scratches inside. The installation method of the magnetic flap level gauge can choose between side installation and top installation, and the lower end of the magnetic flap level gauge body is sealed.
2、 Magnetic flap level gauge is a measuring instrument that uses a magnetic float as the sensing element and reflects the measured liquid level or interface through the magnetic coupling interaction between the magnetic float and the magnetic material in the display column.

4、 The magnetic flap level gauge displayed on the spot has the advantages of displaying straight, eye-catching, wide viewing angle, compact and reliable structure, safe and reliable, no "running, emitting, dripping, leaking" phenomenon, low maintenance and repair costs, and its indication function does not require other power supply. Even if there is a power supply failure, the liquid level measurement will not be affected. It is an imaginary liquid level detection instrument.
5Liquid chlorine storage tank level gaugeIf equipped with UR type resistance level sensors, or UB type resistance current level transmitters and (secondary) display instruments, electric remote transmission can be completed, and standard signal signals of 4-20mA (or 0-10mA) can be output to jointly record the instruments, or industrial control accounting machines can be networked.
6、 There are two installation methods for the magnetic flap level gauge: side mounted and top mounted. Either method can be attached for remote transmission installation, allowing the level gauge to display the liquid level on the spot and monitor it remotely. The bound magnetic flap level gauge can be called a remote transmission type magnetic flap level gauge.
7Liquid chlorine storage tank level gaugeAlso known as magnetic level gauge, magnetic flip column level gauge, magnetic float level gauge, it applies the principle of magnetic coupling to perform tasks. The magnetic flip plate level gauge compensates for the multiple defects of glass tube level gauges that cannot function under high temperature and pressure and are fragile

Installation form and content Side mounted Top mounted
Installation spacing
(Measurement range)
500,800,1100,1400,1700,
2000,2500,3000,3500,4000,
4500,5000,5500,6000mm
500,800,1100,1400,1700,
2000,2500,3000mm
Working pressure 0.6,1.6,2.5,4.0MPa 0.6,1.6,2.5MPa
Medium density ≥ 0.5g/cm 3 ≥ 0.76g/cm 3
Connecting flange stainless steel Flange 20-40 (D N 20 P N 4.0)
(GB9119-88)
Flange 200-25 (D N 200 P N 2.5)
(GB9119-88)
ABS Flange 20-10 (D N 20 P N 1.0) (GB9119-88) Flange 200-6 (D N 200 P N 0.6)
(GB9119-88)
Main material ABS (working pressure 0.6MPa) 1Cr18Ni9T
medium temperature -40 ℃ ~100 ℃ (ABS: -40 ℃ ~80 ℃ )
ambient temperature -40 ℃ ~+70 ℃
Indication error ± 10mm
Viscosity ≤ 1st(10 - 4 m/s)
Upper and lower limit switches
output
1. Control sensitivity: 10mm
2. Output contact capacity: AC220V2A
3. Contact life: 5 × 10 4
Continuous display of electric remote transmission 1. Accuracy: ± 1.5%
2. Output load: seven hundred and fifty
3. Output signal: 0~10mA output, 220VAC power supply
4~20mA output, 24VDC two-wire system
4. Explosion proof feature ia Ⅱ CT4 intrinsic safety type

Liquid chlorine storage tank level gaugeThe parameters
Measurement range: 300-5000mm (can be specially customized when exceeding 5000mm)
Display accuracy: ± 10mm;
Work pressure: Stainless steel lining PTFE: ≤ 2.5MPa;
Stainless steel lining PP: ≤ 1 0Mpa
(Our company can achieve a maximum pressure of 25Mpa, please refer to the high temperature and high pressure instrument for details)
Medium temperature: Stainless steel lining PTFE:- 20~200℃;
Stainless steel lining PP:- 20~90℃
Liquid chlorine storage tank level gaugeMedium density: ≥ 0.5g/cm3;
Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
Medium viscosity: ≤ 0.4Pa·S;
Process connection: DN20/25 PN1.0 (complying with standard HG20592~20635-97), other standards can be manufactured according to customer requirements.
Liquid receiving material: PTFE、PP; (Select according to the chemical properties of the medium and the temperature and pressure of use);
Float material: PTFE、PP、 Stainless steel lined with PTFE, etc.
Liquid chlorine storage tank level gaugeInstallation, use, and maintenance
1. Firstly, check whether the data on the level gauge label matches the ordering requirements. There should be no excitation iron or other magnetic substances within 200mm of the level gauge, otherwise it will affect the normal operation of the level gauge.
2. Liquid chlorine storage tank level gaugeA shut-off valve should be installed between the container to cut off the material during maintenance and cleaning. The installation of the main body must be vertical, with a maximum deviation angle of ≤ 3 °. When the measurement range is greater than 4m, intermediate support points should be added during installation and use.
3. Liquid chlorine storage tank level gaugeBefore entering operation, the upper flange gas phase valve should be opened first, and then the lower flange liquid phase valve should be slowly opened to allow the medium to slowly flow into the cylinder, allowing the flip column (plate) to track and indicate one by one, and adjust the zero liquid level with adjusting screws.
4. The protective conduit and main conduit of the liquid level gauge must be kept vertical
5Liquid chlorine storage tank level gaugeAfter installation, the flip column of the monitor needs to be guided once with magnetic steel to display red above zero and white below zero.
Liquid chlorine storage tank level gaugeScope and characteristics of application
Liquid chlorine storage tank level gaugeIt is based on the reference of similar products at home and abroad, actively absorbing and blending the advantages of many products, and carefully designed by the company's technical personnel. By using high-quality magnets and imported electronic components, the product has the advantages of reasonable design, simple structure, convenient use, stable performance, long service life, and easy installation and maintenance.
Meanwhile,Liquid chlorine storage tank level gaugeWith the changing market demand, the company's products are constantly upgrading their quality technology and improving their production processes, expanding the application areas and scope of this liquid level gauge. In addition, this liquid level gauge has diverse output signals, enabling remote liquid level indication, detection, control, and recording.
This liquid level gauge is almost applicable for liquid level measurement and control in various industrial automation processes. It can be widely used for liquid level measurement, control, and monitoring in fields such as petroleum processing, food processing, chemical engineering, water treatment, pharmaceuticals, electricity, papermaking, metallurgy, ships, and boilers.
Liquid chlorine storage tank level gaugeOrdering Notice
Please indicate the model specifications, measurement range, installation depth, medium density, medium temperature, and working pressure when placing an order.
If users use JB and HG flanges or other specifications of flanges, they can specifically request them, and our professional personnel will assist you in selecting or designing special products for you.
Users are required to provide their own flange and sealing gasket connectors according to the table below. The relevant dimensions and sealing dimensions of the flange provided by the user are shown in the following figure and table:
Installation type Material Nominal diameter Nominal pressure DN
(mm)
Outer diameter of flange PN (Mpa) Screw bolt circular hole with straight center diameter K Screw hole diameter L bolt Sealing surface Flange thickness C Flange gasket
Quantity n Thread Th d f outside diameter inside diameter thickness
Side stainless steel 20 4.0 105 75 14 4 M12 56 2 16 61 27 2
ABS 20 1.0 105 75 14 4 M12 56 2 16 61 27 2
Top mounted stainless steel 200 2.5 360 310 26 12 M24 274 3 32 284 220 2
ABS 200 0.6 320 280 18 8 M16 258 3 24 262 220 2


1. JKM-UHZ-F anti-corrosion typeLiquid chlorine storage tank level gaugeThe installation position should avoid or be far away from the inlet and outlet of the material medium to prevent rapid changes in the local area of the material fluid, which may affect the accuracy of liquid level measurement;
2. For level gauges that exceed a certain length (ordinary type>3 meters, anti-corrosion type>2 meters), it is necessary to add a reinforced flange or ear hook as a fixed support to increase strength and overcome its own weight;
3. JKM-UHZ-F anti-corrosion typeLiquid chlorine storage tank level gaugeWhen debugging, the upper guide valve should be opened first, and then the lower valve should be slowly opened to allow the medium to enter the main pipe smoothly (during operation, the medium should avoid rapid impact on the float, causing the float to fluctuate dramatically and affecting display accuracy), and observe the flipping of the magnetic red and white balls
4Liquid chlorine storage tank level gaugeCheck if the operation is normal, then close the lower inlet valve, open the drain valve, and let the liquid level in the main inlet decrease. Follow this method three times, and if it is normal, it can be put into operation (except for corrosive and other special liquids);
5. According to the condition of the medium, the main pipe should be cleaned irregularly to remove impurities;
6Liquid chlorine storage tank level gaugeWhen equipped with remote transmission instruments, the following measures should be taken:
a.Liquid chlorine storage tank level gaugeThe remote transmission supporting instruments should be tightly attached to the main pipe of the liquid level gauge and fixed with stainless steel clamps (iron is prohibited);
b. The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the liquid level gauge;
c. The connection between the remote transmission supporting instrument and the display instrument or industrial control computer is best laid separately through a protective tube or with a shielded two core cable;
d.Liquid chlorine storage tank level gaugeAfter the wiring holes of the junction box are laid, it is required to be well sealed to prevent rainwater, moisture, and other factors from entering and causing the remote transmission supporting instruments to malfunction. The junction box should be promptly covered after maintenance or debugging is completed.