Beijing Zhongke Xinyi Technology Co., Ltd
Home>Products>M5 PID Five in One Gas Detector
M5 PID Five in One Gas Detector
The VOC in the working environment of M5 PID five in one gas detector can cause various hidden dangers. VOCs are easily evaporated at room temperature
Product details

M5 PIDFive in one gas detectorProduct Features

1. Integrated shell, both shockproof and waterproof

Two LCD displays can continuously display five gas concentrations simultaneously

Measure VOC (volatile organic compounds) from 0-1000 ppm

4 connected sampling pumps can be used for remote sampling

5 power supply methods: AA alkaline battery or rechargeable battery pack that can be replaced anywhere

When the alarm is triggered, it emits a high pitched sound of 95 decibels and two bright wide-angle warning lights

7 built-in vibration alarm, suitable for very noisy environments

8 Supports multiple languages: English, French, German, Spanish, Spanish, and Portuguese

There are three background light modes to choose from: standard mode - low light (automatic),

Activate automatically upon alarm and when needed; Alarm mode - activated under alarm,

Activate again when needed; Secret Mode

10 four alarm levels: instantaneous low and high limit alarms for all gases; VOC and Toxic

TWA (Time Weighted Average) and S (Short term Exposure Limit) alarms for gases

11 Simple Automatic Calibration Program; With BW MicroDock II

Compatible with automatic testing and calibration stations

Display the maximum values of TWA, S, and gas exposure under 12 records and instructions

13 on-site options that users can choose from include: PID/combustible gas correction factor, language selection

Select, prompt sound, calibrate gas concentration, set TWA/S calculation options, settings

Calibration expiration date, password protection, lock alarm, "SAFE" display function, silent mode

Formula and select the ppm accuracy of certain gases (such as setting the measurement accuracy of SO2 to

0.1 ppm)

14. Full function self check includes: integrity of sensors, batteries, and circuits;

Auditory/visual alarm

Compared to similar instruments, the 15 is more compact and reduces weight by more than half

M5 PIDFive in one gas detectorTechnical Parameter

Canadian BW M5PIDFive in one gas detectorSpecification of volatile organic compound detector sensor:

gas

Measurement range (ppm)

Default accuracy (ppm)

high-precision

H2S

0-500

1

0.1

CO

0-999

1

Not Applicable

H2S (Twin Tox Sensor)

0-500

1

0.1

CO (Twin Tox Sensor)

0-500

1

Not Applicable

O2

0-30.0%

0.10%

Not Applicable

SO2

0-150

1

0.1

PH3

0-5.0

1

0.1

NH3

0-100

1

0.1

NO2

0-99.9

1

0.1

HCN

0-30.0

1

0.1

Cl2

0-50.0

1

0.1

ClO2

0-1.0

0.1

0.1

O3

0-1.0

0.1

0.1

PID(VOCs)

0-1000

1

Not Applicable

IR(CO2)

0-50,000

150

Not Applicable

0-5.0% v/v

0.01%

combustible gas

0-100% LEL

1%

Not Applicable

0-5.0% v/v

0.10%

M5 PIDFive in one gas detector

Automatic zeroing: Yes

Correction: Automatic

Backlight: Standard mode: Low light (automatic); Alarm condition (automatic); Can be reactivated according to demand

Alarm mode: Alarm condition (automatic), activated again as needed

Secret mode: The backlight does not light up, and the sound and light alarm is disabled

Full function self-test: integrity of sensors, circuits, and batteries; Sound/visual alarm

Sensor: 10.6eV PID (VOC) lamp; Plug in electrochemical sensors (for toxic gases and oxygen) or catalytic sensors (LEL)

User options: prompt sound, set S cycle, force calibration at startup, enable/disable sensors, password protection, lock alarm, change range, user lock option after successful calibration, "SAFE" display function, silent mode

Fast pump, automatic oxygen calibration upon startup, alarm in background light mode only, combustible gas measurement (% LEL or methane volume percentage), LCD language options, S calculation selection, TWA calculation selection, PID/combustible gas

Correction factor options, user set calibration gas concentration, high precision, clock

Pump: The pipe connection length can reach 100 feet/30 meters (standard configuration 50 feet/15 meters), and users can make corresponding choices

Alarm indicator light: visual, sound/vibration alarm clearly displays the alarm status and level

Visual alarm: Two bright flashing wide-angle warning lights

The LCD screen displays the gas and alarm levels that appear

Sound alarm: A typical high output variable pulse alarm sound of 95 decibels from 1 foot/0.3 meters away

Vibration alarm: issue vibration warning in gas alarm state or display other alarm conditions

Status alert: Low battery level, out of measurement range, multiple gas/pump failures, or sensor malfunction

Alarm level: instantaneous low and high limit alarms for all gases; TWA (Time Weighted Average) and S (Short Term Exposure Limit) alerts for toxic gases/VOCs

LCD: Continuous alphanumeric gas reading and status display instructions:

Gas detection type: VOC (PID), H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3, Combustible gas (0-100% LEL or 0-5% methane)

Gas concentration: Continuously display all gas concentrations (ppm,% LEL, or% v/v) simultaneously

Peak value (maximum value)/S/

TWA (ppm or%): Record exposure values and display them as needed

Alarm Setpoint: Displayed at startup and when needed

Calibration expiration date: the remaining days at the time of startup

Clock: Display real-time time at startup

Testing:

Full function self-test: Check the status of sensors, wiring, and battery condition at startup and sound/light alarms

Battery: Uninterrupted

General specifications: impact resistant composite material, double-layer injection molded shock-absorbing sheath

Working temperature: For VOC (PID), 14 to 104 ℉/-10 to 40 ℃; For other gases, -4 to 122 ℉/-20 to 50 ℃

Humidity: 0% to 95% relative humidity (no condensation)

EMI/RFI: Complies with EMC guidance specification 89/336/EEC

Protection level: High performance waterproof and dustproof shell

Optional battery types: If equipped with PID, oxygen, combustible gas, and TwinTox 2-in-1 (hydrogen sulfide/carbon monoxide) sensors, it can run for 12 hours using 3 AA alkaline batteries and 10 hours using a replaceable rechargeable battery pack

Size: 5.7 × 2.9 × 1.5 inches/14.5 × 7.4 × 3.8 centimeters

Weight: 13.1 ounces/370 grams

Warranty period: Two years of complete warranty, including all sensors (PID lamp and NH3 sensor for 1 year)

Data logger option: User downloads data logger

Data recording: All faults and events (zero calibration adjustment, range calibration adjustment, gas reading, TWA, S, alarm status, faults detected by microprocessor)

Sampling rate: The factory preset interval is 5 seconds, and users can set it between 1 and 127 seconds by themselves

Storage: 32 MB MMC flash card (optional 64 MB and 128 MB flash cards) records data every 5 seconds and can be continuously recorded for 2 months; When the flash card is full, the data will overwrite the earliest data (rewind function)