M5 PIDFive in one gas detectorProduct Features
1. Integrated shell, both shockproof and waterproof
Two LCD displays can continuously display five gas concentrations simultaneously
Measure VOC (volatile organic compounds) from 0-1000 ppm
4 connected sampling pumps can be used for remote sampling
5 power supply methods: AA alkaline battery or rechargeable battery pack that can be replaced anywhere
When the alarm is triggered, it emits a high pitched sound of 95 decibels and two bright wide-angle warning lights
7 built-in vibration alarm, suitable for very noisy environments
8 Supports multiple languages: English, French, German, Spanish, Spanish, and Portuguese
There are three background light modes to choose from: standard mode - low light (automatic),
Activate automatically upon alarm and when needed; Alarm mode - activated under alarm,
Activate again when needed; Secret Mode
10 four alarm levels: instantaneous low and high limit alarms for all gases; VOC and Toxic
TWA (Time Weighted Average) and S (Short term Exposure Limit) alarms for gases
11 Simple Automatic Calibration Program; With BW MicroDock II
Compatible with automatic testing and calibration stations
Display the maximum values of TWA, S, and gas exposure under 12 records and instructions
13 on-site options that users can choose from include: PID/combustible gas correction factor, language selection
Select, prompt sound, calibrate gas concentration, set TWA/S calculation options, settings
Calibration expiration date, password protection, lock alarm, "SAFE" display function, silent mode
Formula and select the ppm accuracy of certain gases (such as setting the measurement accuracy of SO2 to
0.1 ppm)
14. Full function self check includes: integrity of sensors, batteries, and circuits;
Auditory/visual alarm
Compared to similar instruments, the 15 is more compact and reduces weight by more than half
M5 PIDFive in one gas detectorTechnical Parameter
Canadian BW M5PIDFive in one gas detectorSpecification of volatile organic compound detector sensor:
gas |
Measurement range (ppm) |
Default accuracy (ppm) |
high-precision |
H2S |
0-500 |
1 |
0.1 |
CO |
0-999 |
1 |
Not Applicable |
H2S (Twin Tox Sensor) |
0-500 |
1 |
0.1 |
CO (Twin Tox Sensor) |
0-500 |
1 |
Not Applicable |
O2 |
0-30.0% |
0.10% |
Not Applicable |
SO2 |
0-150 |
1 |
0.1 |
PH3 |
0-5.0 |
1 |
0.1 |
NH3 |
0-100 |
1 |
0.1 |
NO2 |
0-99.9 |
1 |
0.1 |
HCN |
0-30.0 |
1 |
0.1 |
Cl2 |
0-50.0 |
1 |
0.1 |
ClO2 |
0-1.0 |
0.1 |
0.1 |
O3 |
0-1.0 |
0.1 |
0.1 |
PID(VOCs) |
0-1000 |
1 |
Not Applicable |
IR(CO2) |
0-50,000 |
150 |
Not Applicable |
0-5.0% v/v |
0.01% |
||
combustible gas |
0-100% LEL |
1% |
Not Applicable |
0-5.0% v/v |
0.10% |
M5 PIDFive in one gas detector
Automatic zeroing: Yes
Correction: Automatic
Backlight: Standard mode: Low light (automatic); Alarm condition (automatic); Can be reactivated according to demand
Alarm mode: Alarm condition (automatic), activated again as needed
Secret mode: The backlight does not light up, and the sound and light alarm is disabled
Full function self-test: integrity of sensors, circuits, and batteries; Sound/visual alarm
Sensor: 10.6eV PID (VOC) lamp; Plug in electrochemical sensors (for toxic gases and oxygen) or catalytic sensors (LEL)
User options: prompt sound, set S cycle, force calibration at startup, enable/disable sensors, password protection, lock alarm, change range, user lock option after successful calibration, "SAFE" display function, silent mode
Fast pump, automatic oxygen calibration upon startup, alarm in background light mode only, combustible gas measurement (% LEL or methane volume percentage), LCD language options, S calculation selection, TWA calculation selection, PID/combustible gas
Correction factor options, user set calibration gas concentration, high precision, clock
Pump: The pipe connection length can reach 100 feet/30 meters (standard configuration 50 feet/15 meters), and users can make corresponding choices
Alarm indicator light: visual, sound/vibration alarm clearly displays the alarm status and level
Visual alarm: Two bright flashing wide-angle warning lights
The LCD screen displays the gas and alarm levels that appear
Sound alarm: A typical high output variable pulse alarm sound of 95 decibels from 1 foot/0.3 meters away
Vibration alarm: issue vibration warning in gas alarm state or display other alarm conditions
Status alert: Low battery level, out of measurement range, multiple gas/pump failures, or sensor malfunction
Alarm level: instantaneous low and high limit alarms for all gases; TWA (Time Weighted Average) and S (Short Term Exposure Limit) alerts for toxic gases/VOCs
LCD: Continuous alphanumeric gas reading and status display instructions:
Gas detection type: VOC (PID), H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3, Combustible gas (0-100% LEL or 0-5% methane)
Gas concentration: Continuously display all gas concentrations (ppm,% LEL, or% v/v) simultaneously
Peak value (maximum value)/S/
TWA (ppm or%): Record exposure values and display them as needed
Alarm Setpoint: Displayed at startup and when needed
Calibration expiration date: the remaining days at the time of startup
Clock: Display real-time time at startup
Testing:
Full function self-test: Check the status of sensors, wiring, and battery condition at startup and sound/light alarms
Battery: Uninterrupted
General specifications: impact resistant composite material, double-layer injection molded shock-absorbing sheath
Working temperature: For VOC (PID), 14 to 104 ℉/-10 to 40 ℃; For other gases, -4 to 122 ℉/-20 to 50 ℃
Humidity: 0% to 95% relative humidity (no condensation)
EMI/RFI: Complies with EMC guidance specification 89/336/EEC
Protection level: High performance waterproof and dustproof shell
Optional battery types: If equipped with PID, oxygen, combustible gas, and TwinTox 2-in-1 (hydrogen sulfide/carbon monoxide) sensors, it can run for 12 hours using 3 AA alkaline batteries and 10 hours using a replaceable rechargeable battery pack
Size: 5.7 × 2.9 × 1.5 inches/14.5 × 7.4 × 3.8 centimeters
Weight: 13.1 ounces/370 grams
Warranty period: Two years of complete warranty, including all sensors (PID lamp and NH3 sensor for 1 year)
Data logger option: User downloads data logger
Data recording: All faults and events (zero calibration adjustment, range calibration adjustment, gas reading, TWA, S, alarm status, faults detected by microprocessor)
Sampling rate: The factory preset interval is 5 seconds, and users can set it between 1 and 127 seconds by themselves
Storage: 32 MB MMC flash card (optional 64 MB and 128 MB flash cards) records data every 5 seconds and can be continuously recorded for 2 months; When the flash card is full, the data will overwrite the earliest data (rewind function)