MINI-MAX bolt stress tester
|
☆ Measurement range: 2.54cm to 244cm
|
☆ Operating frequency: 1250-99999m/s
|
☆ Detection accuracy: 1
|
☆ Indication error: 0.0001mm
|
Product Introduction
----------------------------------------------------------------------
The MINI-MAX bolt stress tester adopts advanced ultrasonic reflection technology, which can accurately and quickly measure the duration and elongation of bolt tightening, and further convert them into load, stress, and strain. It has the characteristics of easy use, intuitive display, and portability. The MINI-MAX bolt stress tester is widely used in fields such as aerospace, satellite manufacturing, power equipment, construction bridges, and petrochemicals due to its unique concept, powerful functions, and accurate measurements.
Performance characteristics:
-
Measurable values: time/elongation/load/stress/strain
-
Display VGA (240 X 160)
-
Measurement mode: Interface wave echo; Interface wave echo with gate
-
Automatic probe recognition
-
Serial port and alarm output interface
-
Can store 8000 readings and waveforms
-
Windows interface computer communication software
- MINI-MAX Technical Parameters:
-
External dimensions63.5x165x31.5mmweight380g (including battery) all metal casingDisplay screen resolution240X160 pixelsdisplay modeFull wave, positive/negative half wave, digital or split screen combined display (waveform+digital)working temperature-10~60℃Detection range2.54cm~244cm (steel, P-E mode, may vary due to different materials)Data communication interfaceCan be connected to a PC computerStorage formatTable format (letter, number numbering) or sequential format (automatic numbering)Storage capacityCan store 8000 readings and waveformsCustom parameter settingsCan store 64 parameter settings, built-in parameter settings can also be edited by usersBatteryPowered by 3 No. 5 dry batteriesgain40dB (minimum step spacing 0.2dB), can be adjusted for gain at any time (manual or automatic gain control)On site calibrationVector method or linear regression can be used for calibration to increase measurement accuracyMeasurement unitMetric (mm)/Imperial (in)sound velocity1250~9999m/s, continuously adjustableMeasurement modeInterface wave echo (P-E); Interface wave echo with gate (P-E w/Gate)Display resolution0.0001mmCalibration modeFixed/One Point/Two Point CalibrationMeasurement unitTime ns elongation in/mm load KIP/KN stress KSI/MPa strain -%Probe type1MHz-10MHz single crystal probe (diameter 1/8 ''~1 '' optional), magnetic/non-magnetic optional, small bolt can be used to install the probe by pasting, users can customize the probeProbe cable socketLEMO 00 interface and temperature sensor interface (optional)Certification standardsCompliant with NIST&MIL-STD-45662A
Common probes:
model |
frequency |
wafer diameter |
PT# T-700-2405 |
5MHz |
1/8 inch |
PT# T-700-4405 |
10MHz |
1/8 inch |
PT# T-702-2405 |
5MHz |
1/4 inch |
PT# T-702-4405 |
10MHz |
1/4 inch |
PT# T-703-2405 |
5Mhz |
3/8 "inch |
PT# T-703-1405 |
2.25Mhz |
3/8 "inch |
PT# T-704-2405 |
5MHz |
1/2 inch |
PT# T-704-1405 |
2.25MHz |
1/2 inch |
PT# T-706-2405 |
5MHz Magnetic |
3/4 inch |
PT# T-706-1405 |
2.25Mhz |
3/4 inch |
PT# T-706-0405 |
1MHz |
3/4 inch |
Non magnetic probe |
|
reserve |
Customized probe |
|
reserve |