The gateway serves as a slave on one side of PROFIBUS and has MODBUS/TCP interface protocol (RJ45 interface, based on IEEE802.3, 100M, etc.) on the other side TCP/IP)。 The gateway provides a solution for transmitting PROFIBUS bus data to industrial Ethernet. Devices with MODBUS/TCP protocol interfaces (such as operation screen HMI, PLC, DCS, etc.) can be connected to the PROFIBUS bus and Siemens PLC, meeting the needs of PROFIBUS bus data access to industrial Ethernet or management IT networks.
Application diagram
Standard PROFIBUS-DP slave interface, compliant with IEC61158 TYPE3 PROFIBUS international standard and Chinese national standard GB/T 20540-2006
● Baud rate adaptive 9600-12Mbps;
● Compatible with mainstream PROFIBUS master station equipment, such as Siemens 300/400 PLC, Beckhoff dp master station ABB 800F、 Omron main station, Hollysys
LK PLC、 Hollysys DCS, etc;
Standard MODBUS/TCP protocol interface, compliant with Chinese national standard GB/T19582-2008;
MODBUS/TCP server: supports MODBUS functions for numbers 03H, 04H, 06H, and 10H;
Provide product GSD files for network integration; Realize the mapping from PROFIBUS I/Q data area to MODBUS/TCP data area (0, 1, 3, 4 areas) through the main station configuration;
Memory sharing gateway, MODBUS/TCP clients can directly read PROFIBUS I/Q data through the MODBUS/TCP data area of the gateway;
The status word of the gateway comprehensively reflects the communication status of the gateway and the communication status of the Ethernet;
Wide voltage power supply 24VDC ± 20%, 35mm rail clamp, providing intuitive and effective indicator light function;
● Standard industrial Ethernet interface: IEEE802.3 8pin RJ45 socket; Speed 10/100M, adaptive MDI/MDXI;
Working temperature: -20 ℃ to+55 ℃; Relative humidity at work: 5-95% (no condensation).
|
|
PB-G-ETH | ||||
PROFIBUS
parameter |
standard
|
Compliant with IEC61158 TYPE3 PROFIBUS international standard and Chinese national standard GB/T 20540-2006. | ||||
speed
|
Baud rate adaptive, 9600-12Mbps; | |||||
Data volume
|
PROFIBUS input/output quantity can be freely set, maximum input/output: <1> Input Bytes + Output Bytes ≤ 400 Bytes; <2> Max Input Bytes ≤200 Bytes; <3> Max Output Bytes ≤200 Bytes; |
|||||
Ethernet interface parameters
|
physical interface
|
IEEE802.3 8pin RJ45 socket; Speed 10/100M, adaptive MDI/MDXI; | ||||
agreement
|
TCP/IP+MODBUS/TCP server, compliant with Chinese national standard GB/T19582-2008; | |||||
Data volume
|
Zone 3 (input register): 100 WORDS; Zone 4 (keep register): 100 WORDS; | |||||
function code
|
Support: 03H, 04H, 06H, 10H function codes | |||||
Operational Characteristics
|
collocation method
|
The gateway provides GSD files for the main station to configure the gateway. All communication parameters of the Ethernet interface are set in the PROFIBUS master station configuration (such as STEP7), without the need for additional components to be separately configured and downloaded, reducing operational steps and improving work efficiency. | ||||
Electrical parameters
|
power consumption
|
Power supply: 24VDC (± 20%), current: 110mA (at 24VDC) | ||||
authentication
|
CE certification, PROFIBUS certification | |||||
work environment
|
Working temperature: -20 ℃~+55 ℃ (for customers with lower temperature requirements, please make a purchasing statement); Transportation and storage:- 40℃~+70℃; Relative humidity at work: 5-95% (no condensation) |
|||||
install
|
Method: 35mm guide rail; Protection level: IP20; | |||||
Dimension
|
Dimensions: Width (40.5mm) x Height (114.5mm) x Thickness (83mm); Weight: Approximately 230g | |||||
Product Features
|
Application scenarios
|
Devices with MODBUS/TCP protocol interfaces (such as operation screen HMI, PLC, DCS, etc.) will be connected to the PROFIBUS bus and Siemens PLC, meeting the needs of PROFIBUS bus data access to industrial Ethernet or management IT networks. | ||||
Easy to use
|
All configurations can be completed in the PROFIBUS master station configuration (such as STEP7), without the need for additional components to be separately configured and downloaded, reducing operational steps and improving work efficiency. | |||||
FEATURES
|
Memory sharing gateway, high-speed data transmission, reducing data latency. |
PROFIBUS Slave Gateway Product Appearance and Device Layout
PROFIBUS slave gatewayDimensions and Installation
Products case
![]() |
Project Name: Application of Platform Screen Door Control System for a Railway Line in Tianjin Using the product: PB-G-ETH Connected products: The main station is Siemens 300 series PLC, and the SCADA system in the central control room Implementation function: The SCADA system in the central control room can directly access data on the PROFIBUS DP bus through Ethernet. Effect analysis: Through the application of PB-G-ETH bus bridge, compared to opening up an Ethernet on PROFIBUS DP busThe network interface makes accessing data in the subway system more flexible and convenient. |
![]() |
Project Name: Application of a Sewage Treatment Plant Using the product: PB-G-ETH Connected products: The main station is Siemens 300 series PLC, ABB DCS system Implementation function: The ABB DCS system accesses data on the PROFIBUS DP bus via Ethernet. Effect analysis: The application of PB-G-ETH bus bridge makes the connection between traditional DCS system and PROFIBUS DP bus system more flexible and convenient. |
PB-G-ETH GSD file
PB-G-ETH Product Manual