FC-2G (B) Lightning Protection Component TesterThe varistor tester is suitable for measuring the DC parameters of overvoltage protection components such as zinc oxide lightning arresters (varistors) and metal ceramic two - and three electrode discharge tubes. It can also be used as a voltage regulator, constant current power supply, and applied in other fields.
FC-2G (B) Lightning Protection Component TesterWhen measuring varistors, the DC/DC converter drives a certain high-frequency pulse to increase the 12V DC voltage to the required DC high voltage for testing varistors. When testing the discharge tube, the slope control circuit controls the DC/DC converter to increase the output voltage value within 5-1700V at a rate of 100V per second until the discharge tube is discharged.
FC-2G (B) Lightning Protection Component TesterProduct features:
1. It has functions such as high voltage short-circuit protection, overcurrent protection, high voltage preset, range adjustment, etc., and the high voltage self discharge time is less than 1 second.
2. It has functions of memory, computation, retention, control, and self checking.
3. The measurement data is displayed digitally on a 3 1/2 LCD, with high accuracy and good reliability.
4. During measurement, the range can be pre-set and an audible prompt can be issued for exceeding the range during the measurement process, which is suitable for device grouping and inspection discrimination.
5. Choosing continuous measurement allows for uninterrupted testing of batch samples.
6. The panel has simple functions and is easy to operate.
7. Lightweight and easy to carry.
FC-2G (B) Lightning Protection Component TesterProduct parameters:
1. Varistor measurement
TECHNICAL INDEX | measuring range | operating error | Test conditions |
Initial operating voltage U1mA | 15~100V | ≤±2V±1d | 1mA±5μA |
101~1700V | ≤±2%±1d | ||
Leakage current I0.75U, 1mA | 0.1~199.9μA | ≤2μA±1d | 0.75U1mA≤±2%±1d |
2. Discharge tube measurement
TECHNICAL INDEX | measuring range | operating error | Test conditions |
Discharge Voltage | 20~1700V | ≤±2%±1d | Voltage rise rate 100 ± 8V/s |
Discharge voltage memory display time | 1.5~3.5 seconds |
3. Other indicators
Insulation resistance: 6M Ω (500V)
Voltage resistance: AC1.5kV; 50Hz; 1min
Working temperature and humidity: 0~+40 ℃; < 85%RH
Storage temperature and humidity:- 10℃~+50℃<90%RH
Power supply: AC220V ± 10% or DC12V ± 0.5V; 1000mA
Power consumption: 12W
Dimensions: 208mm (L) × 190mm (W) × 78mm (D)
Weight: ≤ 2kg
Shanghai Xuji Electric Co., LtdcorrectElectrical testing equipment,Transformer detection equipment、High voltage testing equipment、Electricity metering equipment、Secondary circuit detection equipment,Integrated automation of power systemAnd intelligentInstrumentationA high-tech enterprise. The product is widely used in industries such as power systems, scientific research and teaching institutions, water conservancy, petroleum, railways, mining, and chemical engineering.
The company has a strong R&D team and a scientific management system. Adhering to the development philosophy of "forging excellence with professionalism, winning the market with integrity, emphasizing quality and science", we have cultivated and attracted a large number of high-end technical talents in electrical engineering who integrate high, new, and cutting-edge technologies such as power electronics, high voltage, computer measurement and control, software technology, and electronic technology. We are ready to provide customers with convenient and fast service concepts for design, supply, debugging, and maintenance, provide high-quality and perfect products, and create a professional electrical boutique enterprise!
FC-2G (B) Lightning Protection Component TesterThe varistor tester is suitable for measuring the DC parameters of overvoltage protection components such as zinc oxide lightning arresters (varistors) and metal ceramic two - and three electrode discharge tubes. It can also be used as a voltage regulator, constant current power supply, and applied in other fields.
FC-2G (B) Lightning Protection Component TesterWhen measuring varistors, the DC/DC converter drives a certain high-frequency pulse to increase the 12V DC voltage to the required DC high voltage for testing varistors. When testing the discharge tube, the slope control circuit controls the DC/DC converter to increase the output voltage value within 5-1700V at a rate of 100V per second until the discharge tube is discharged.
FC-2G lightning protection component testerMOV varistor tester lightning protection detection equipment kitProduct features:
1. It has functions such as high voltage short-circuit protection, overcurrent protection, high voltage preset, range adjustment, etc., and the high voltage self discharge time is less than 1 second.
2. It has functions of memory, computation, retention, control, and self checking.
3. The measurement data is displayed digitally on a 3 1/2 LCD, with high accuracy and good reliability.
4. During measurement, the range can be pre-set and an audible prompt can be issued for exceeding the range during the measurement process, which is suitable for device grouping and inspection discrimination.
5. Choosing continuous measurement allows for uninterrupted testing of batch samples.
6. The panel has simple functions and is easy to operate.
7. Lightweight and easy to carry.
FC-2G lightning protection component testerMOV varistor tester lightning protection detection equipment kitProduct parameters:
1. Varistor measurement
TECHNICAL INDEX | measuring range | operating error | Test conditions |
Initial operating voltage U1mA | 15~100V | ≤±2V±1d | 1mA±5μA |
101~1700V | ≤±2%±1d | ||
Leakage current I0.75U, 1mA | 0.1~199.9μA | ≤2μA±1d | 0.75U1mA≤±2%±1d |
2. Discharge tube measurement
TECHNICAL INDEX | measuring range | operating error | Test conditions |
Discharge Voltage | 20~1700V | ≤±2%±1d | Voltage rise rate 100 ± 8V/s |
Discharge voltage memory display time | 1.5~3.5 seconds |
3. Other indicators
Insulation resistance: 6M Ω (500V)
Voltage resistance: AC1.5kV; 50Hz; 1min
Working temperature and humidity: 0~+40 ℃; < 85%RH
Storage temperature and humidity:- 10℃~+50℃<90%RH
Power supply: AC220V ± 10% or DC12V ± 0.5V; 1000mA
Power consumption: 12W
Dimensions: 208mm (L) × 190mm (W) × 78mm (D)
Weight: ≤ 2kg
Shanghai Xuji Electric Co., LtdcorrectElectrical testing equipment,Transformer detection equipment、High voltage testing equipment、Electricity metering equipment、Secondary circuit detection equipment,Integrated automation of power systemAnd intelligentInstrumentationA high-tech enterprise. The product is widely used in industries such as power systems, scientific research and teaching institutions, water conservancy, petroleum, railways, mining, and chemical engineering.
The company has a strong R&D team and a scientific management system. Adhering to the development philosophy of "forging excellence with professionalism, winning the market with integrity, emphasizing quality and science", we have cultivated and attracted a large number of high-end technical talents in electrical engineering who integrate high, new, and cutting-edge technologies such as power electronics, high voltage, computer measurement and control, software technology, and electronic technology. We are ready to provide customers with convenient and fast service concepts for design, supply, debugging, and maintenance, provide high-quality and perfect products, and create a professional electrical boutique enterprise!