MXT protection columns and gas pipelines processed by Hydroguard technology
? Preventing column degradation caused by severe water injection similar to "steam cleaning", thereby extending the service life of the column ? High
Product details

Hydroguard®Technically processedMXT®Protect columns and gas pipelinesPassivation stainless steel pipe

·Preventing column degradation caused by strict water injection similar to "steam cleaning", thereby extending the service life of the column
·Zui high temperature:430 °C

order No#
inside diameter
outside diameter
length
unit
70080
0.28mm
0.56 ± 0.025mm
5m
ea.
70083
0.28mm
0.56 ± 0.025mm
10m
ea.
70086
0.28mm
0.56 ± 0.025mm
30m*
ea.
70089
0.28mm
0.56 ± 0.025mm
60m*†
ea.
70081
0.53mm
0.74 ± 0.025mm
5m
ea.
70084
0.53mm
0.74 ± 0.025mm
10m
ea.
70087
0.53mm
0.74 ± 0.025mm
30m*
ea.
70090
0.53mm
0.74 ± 0.025mm
60m*†
ea.
Showing 1 to 8 of 8 entries
Description:
·Preventing column degradation caused by strict water injection similar to "steam cleaning", thereby extending the service life of the column
·Zui high temperature:430 °C
Purge/The gas pipelines of capture systems, atmospheric monitoring equipment, or other devices that can generate condensed water vapor will quickly become active due to the reaction of free silane groups. Silane groups can absorb active oxidizing compounds such as alcohols and diols.
RestekThe chemist has already dealt with this problem and found a solutionHydroguard®Technical passivation process. The unique passivation process produces a high-density surface, which protects the performance from aggressive hydrolysis attacks.Hydroguard®The high-density surface layer passivated by the technology can effectively prevent water vapor from entering below the surface layer of fused silica. useHydroguard®Column tube connectionGCsTo:
·Headspace analyzer.
·Atmospheric analysis equipment and concentrators
*30-and60-The meter long column is tied to5-In the segmental box of rice.
Suggestion: Take60-Cut the meter long column into small sections for use, as being too long can easily cause spectral peak distortion.
Diameter greater than0.10mmThe pillar tubeGrobDetect the mixture to ensure high inertness.