In research experiments, pressure measurement is divided into three categories: 1. Indirect pressure measurement (such as tail sleeve method). Disadva
Product details

In the research experiment, pressure measurement is divided into three categories
1. Indirect pressure measurement (such as tail sleeve method). Disadvantages: unable to accurately measure diastolic blood pressure, unable to continuously measure blood pressure
2. Direct pressure measurement method using liquid filled conduit. Disadvantages: Bubbles affect the results, changes in the height of the pressure sensor affect the results, slow frequency response and noise generation
3. Quickly respond to solid-state sensor catheter pressure measurement (Scisense catheter). It can accurately measure the pressure at the location of interest. Easy to use.

Scisense Inc. is the only company in the world that can provide a 1.2F diameterSolid pressure sensorAccording to the paper by Woldbaek et al. (Am J Physiol Heart Circ Physiol 285: H2233-H2239, 2003), this is the most ideal experimental tool for mouse experiments. The commonly used 1.4F catheter in previous experiments actually affects arterial blood flow and other hemodynamic parameters. However, for diameters less than 1.2F, its advantages are not obvious, and its service life will be shortened.


As is well known, mouse models are increasingly being used in cardiovascular research. The Scisense microsensor is not only durable but also easy to use. Its professional design is particularly suitable for assisting in transgenic and gene targeting operations in genomic mice.
These pressure sensors have a tip with a diameter of 0.39 millimeters. Connected to the tip is a smaller 0.9F polyimide catheter (0.29mm diameter) that minimizes vascular obstruction and provides optimal flexibility.
For rats, we provide pressure sensors with the same high precision and connect them to a catheter with a diameter of 1.6F. To provide a wider range of flexibility and durability, we offer conduits in various sizes from 1.2F to 7F. Can be used forMouse, rat, rabbit, dog, pigWaiting for various animals. And use polyimide or nylon material. The length of the catheter can also be selected as 66 centimeters or a custom length.

Typical applications

Arterial pressure (systolic, diastolic, mean, etc.) PWV
Intraventricular pressure (e.g. dp/dt, left ventricular end diastolic pressure LVEDP) intracranial pressure
venous pressure Inter organizational fluid pressure/organizational pressure
Gastrointestinal Pressure Dynamics Internal pressure in other organ cavities
Urogenital tract pressure dynamics In vitro research
intraocular pressure Industry Research



Blood pressure measurement (top)


Left ventricular pressure measurement LVP (top) and pressure change rate dp/dt (bottom)



Extremely small pressure conduit size

Catheter Model

FT111B (mouse)

FT211B(rat)
Material Polyimide Polyimide
Catheter Overall Length 65 cm (26") 65 cm (26")
Sensor Tip Diameter 1.2 French(0.40 mm) 1.6 French(0.63 mm)
Catheter Diameter 0.9 French(0.29 mm) 1.6 French(0.53 mm)
Pressure Sensor Orientation side-mounted at tip side-mounted at tip
Re-usable yes yes


Pressure conduit parameters

Measurement Range -50 to + 300 mmHg (temperature range: 32-42°C)
Sensitivity 10 µV/V/mmHg
Frequency Response 0 to >10 kHz
Gauge Excitation Constant current
Stability Zero offset drift < 6 mmHg/24 hours
Signal Gain Factor 200


pressure control unit

The pressure control unit used in the pressure conduit includes a signal collector and an amplification circuit to provide an analog pressure signal and output it to any third-party data acquisition system. The output signal is outputted through a standard BNC interface and an 8-pole 300Hz filter suitable for high-frequency noise suppression.


Technical parameters of control unit
Model FP891A
Pressure Output 2.2 Volt/100 mm Hg
Power Supply External AC power +/- 12 Vdc
Output Filter 300 Hz Low Pass MFB
Dimensions:(H x W x L) 6.6 cm (2.6”) X 11.7 cm (4.6") X 15.4 cm (6")
Calibration Controls Zero and +100 mmHg
Catheter Connector 91 cm (36”) or 152 cm (60”) cables
Output Connector BNC


Other pressure conduit sizes

Catheter Model FT112A
(Mouse)
FT212A
(Rat)
FT316A
(Rabbit)
FT516A
(Dog/Pig)
FT716A
(Dog/Pig)
Material Polyimide Nylon Nylon Nylon Nylon
Catheter Overall Length 45 cm (18") 45 cm (18") 45 cm (18") 120 cm (40") 120 cm (40")
Sensor Diameter 1.2 French
(0.39 mm)
1.9 French
(0.63 mm)
3.0 French
(.98 mm)
5 French
(1.67 mm)
7 French
(2.30 mm)
Catheter Diameter 0.9 French
(0.29 mm)
1.6 French
(0.53 mm)
2.6 French
.87 mm)
5 French
(1.67 mm)
7 French
(2.30 mm)

Pressure Sensor Orientation

side-mounted at tip side-mounted at tip side-mounted at tip side-mounted at tip side-mounted at tip
Tip Characteristics Straight Straight Straight Curved Curved
Re-usable yes yes yes yes yes