Microchip reactorsummary:
This reactorIt is the integration of basic operational units such as sample preparation, reaction, separation, and detection in biological, chemical, and medical analysis processes onto a micrometer scale chip, automatically completing the entire analysis process.
Microchip reactorParameters:
model |
MWO-1000A |
MWO-1000S |
|
|
|
|
|
Response |
Open chemical reaction (heating, draining, stirring, gas replacement) |
||
capacity |
5~200mL |
5~200mL |
|
Container for reaction |
Small reaction container (3 test tubes with a capacity of 5-30mL) Large reaction vessel (4-hole eggplant shaped flask with a capacity of 30-200mL) |
||
Number of reaction containers |
1 unit |
1 unit |
|
mixing method |
Magnetic stirring method |
Magnetic stirring method |
|
sexually ability |
Temperature monitoring range |
Room temperature from+10~250℃ When monitoring temperature in advance |
|
output power Monitoring range |
0~500WWhen monitoring the output power in advance |
||
Range of operating times |
100~1300rpm/1.3kgf·cm |
||
Temperature setting and indication |
Keyboard input and numerical representation |
Touch panel input and numerical representation |
|
Mixing setting · indication |
Volume setting and numerical representation |
Volume setting and numerical representation |
|
Monitoring subject |
The instrument itself monitors |
Instrument monitoring itself or computer monitoring |
|
program |
Timed operation, automatic stop |
Adjust temperature and program (when connected to a computer) Timed operation, automatic stop |
|
External devices |
------ |
USB |
|
Cooling performance |
Non polar solvent (silicon) circulation ※ Optional |
Non polar solvent (silicon) circulation ※ Optional |
|
safety performance |
Magnetron heating, independent monitor for instrument door opening, abnormal sensing, and prevention of sudden temperature rise Circuit breakers with maximum energy reaching temperature (limited to S-type), emergency stop switch (limited to S-type), leakage and overcurrent |
||
construct accomplish |
Number of vibration frequencies |
2450±300MHz |
2450±300MHz |
output power |
500W |
500W |
|
sensor |
A heat sensor coated with Teflon and a pair of sensors (for temperature regulation and prevention of sudden temperature rise) |
||
instrument for drawing circles check |
Heating the material inside the room |
SUS 304 |
SUS 304 |
Size of heating chamber |
180W×180D×250H(mm) |
180W×180D×250H(mm) |
|
Use the surrounding temperature range |
10~35℃ |
10~35℃ |
|
Dimensions(mm) |
460W×390D×440H |
460W×390D×440H |
|
weight |
make an appointment35Kg |
make an appointment35Kg |
|
Rated power supply and power input |
AC 100V 50/60Hz 15A |
AC 100V 50/60Hz 15A |
Ultrasonic reactor, Microbial reactor