Multidimensional gas chromatograph (combustion)Gas analysis system)
Multidimensional gas chromatograph (gas analyzer system) for other industriesscope of application:
Coke oven gas, artificial gas, converter gas, blast furnace gas, natural gas, refinery gasWater gas, semi water gas, liquefied petroleum gas
Multidimensional gas chromatograph (gas analysis system))brief introduction:
The gas analysis system solves the problems of hydrogen, oxygen, nitrogen, carbon monoxide, and carbon dioxide in one injection through automatic ten way valve automatic injection cutting and blowback technology(Installing a converter can analyze ppm level CO CO2)Complete analysis of gases such as methane, ethane, ethylene, acetylene, propane, cyclopropane, propylene, propylene diene, propyne, n-butane, isobutane, n-butene, isobutene, maleic, isobutene, isopentane, n-pentane, 1,3-butadiene, n-hexane, etc.
Execution standards:
GB/T 10410-2008 Gas Chromatography Analysis Method for Constant Components of Artificial Gas and Liquefied Petroleum Gas
GB/T 12208-2008 Determination of Composition and Impurity Content of Artificial Gas
GB/T 11062-1998 "Calculation Method for Heating Value, Density, Average Density, and Wopo Index of Natural Gas"
SH/T 0230-92 "Determination of Composition of Liquefied Petroleum Gas (Chromatography Method)"
GB/T 13610-2003 "Composition Analysis of Natural Gas - Gas Chromatography Method"
GB/T 12206-2006 "Determination of Heating Value and Relative Density of Urban Gas"
GB 10410.1-89 "Gas Chromatography Analysis Method for Components of Artificial Gas"
GB 10410.2-89 "Gas chromatographic analysis of constant components in natural gas"
GB 10410.3-89 "Gas Chromatography Analysis of Liquefied Petroleum Gas Components"
Performance characteristics:
Based on the new generation high-performance and high stability GC-7900 gas chromatograph, it operates reliably and stably.
◆ Wide applicability, can be used for various types of gas analysis.
◆ Adopting a multidimensional chromatography system, it can drive up to 6 injection or cutting valves, and install n packed columns or capillary columns as needed.
Injection method: Valves can be connected in series for injection or injected separately, which can achieve split injection without splitting.
Detector: thermal conductivity detector, hydrogen flame detector, flame photometric detector, and installation of conversion furnace. It can be used in series or separately.
◆ Equipped with 4/8 liter aluminum bottles for multi-component standard mixed gas or single component gas.
◆ Dual channel chromatography workstation, supporting Windows XP operating system, allows for free storage, data processing, and report printing of chromatographic analysis spectra.
◆ It can be equipped with a natural gas analysis chromatography workstation, which can calculate technical parameters such as natural gas calorific value, white number, relative density, compressibility factor, etc.
◆ Can achieve online automatic analysis,By laying pipesroadThe instrument canAutomatically sampling on a periodic basis and monitoring the process sample gas without interruptionAutomatic calibration, no need for manual verification.piperoadIn areas where the probe has not been installed, manual sampling and testing can be used, which is flexible and reliable.
instrumentTechnical indicators:
Hydrogen flame ionization detector (FID):
Cylindrical collection electrode structure design, quartz nozzle, responsive*
Detection limit: ≤ 8×10-12g/s(n-Hexadecane/Isooctane)
Baseline noise: ≤ 2×10-13A
Baseline drift:≤2×10-12A/30min
Linear: ≥ ten6
Stable time: Ten minutes
Thermal conductivity detector (TCD):
Adopting a semi diffusive structure
The power supply adopts constant current control mode
Sensitivity: ≥3000mV·ml/mg, high sensitivity≥8000mV·ml/mg
Baseline noise: ≤10 μ V.
Baseline drift: ≤ 100 μ V/30min.
linear:≧104
3. Large screen LCD display:
Clearly display the set values, measured values, and protection values of each temperature channel
Real time display of instrument status
Touch sensitive keyboard, menu based operation
4Temperature control indicators:
Column box: at room temperature5℃~399℃Accuracy ± 0.1℃
Sample injector: at room temperature5℃~399℃Accuracy ± 0.1℃
Detector: at room temperature5℃~399℃Accuracy ± 0.1℃
5. Quantitative repeatability RSD≤3%
6. Qualitative repeatability RSD≤1%
7. Detection range: 0.01% -99.99%
Multidimensional gas chromatograph (gas analyzer system)System composition:
name |
Model and configuration |
origin |
gas chromatograph |
GC-7900/7890/9860, TCD detector, FID detector |
Shanghai |
sampling device |
Pneumatic valve automatic sampling |
Shanghai |
Cutting method |
Pneumatic valve automatic cutting |
Shanghai |
chromatographic column |
Customize according to specific customer requirements |
Shanghai |
data processing system (Choose one) |
Dual channel data processing system (instrument signal with two outputs) |
Shanghai |
Gas workstation |
Shanghai |
|
Carrier gas for chromatography (Customized according to requirements) |
Nitrogen generator 300ml/min, 500ml/min |
Shanghai |
hydrogen generator 300ml/min, 500ml/min |
Shanghai |
|
Nitrogen purity 99.999% |
Shanghai |
|
Argon purity 99.999% |
Shanghai |
|
Helium purity 99.999% |
Shanghai |
|
Standard gas |
4/8-liter aluminum bottle with pressure reducing valve (customized according to customer needs) |
Shanghai |
Starter Kits |
Shanghai |
|
Computer, printer |
self-provide |
Shanghai Xuansheng Scientific InstrumentsManufacturers of synthetic gas detectors/analyzersOur company's gas chromatograph is in a prominent position in the domestic instrument industry. We solemnly promise to provide a one-year warranty for the entire instrument, with an annual fee and lifetime after-sales service.