NKZ41HVacuum isolation gate valveproduct overview:
The connection form of vacuum isolation gate valve is divided into flange and welding, and there are two driving modes: manual and electric. This vacuum isolation gate valve is suitable for working temperature≤425℃and≤550℃As an opening and closing device on pipelines with working media such as water, steam, or air; Especially suitable for steam turbine condensation and vacuum negative pressure systems in thermal power plants, it plays a role in vacuum isolation and sealing.
Structural characteristics
1Designed a vacuum sealed structure packing chamber to isolate the system from the atmosphere and have good environmental performance.
2The materials are carefully selected and meet relevant national and international standards, with high overall quality.
3The advanced and reasonable pairing of sealing pairs improves sealing performance and has a long service life.
4The opening and closing components adopt parallel gate bi-directional elastic sealing, with low friction, easy opening and closing, convenient maintenance, reliable sealing, and excellent performance.
5The valve stem has undergone quenching and surface nitriding treatment, exhibiting excellent corrosion resistance, abrasion resistance, and wear resistance.
6The flange gasket is made of composite material, which has a large expansion coefficient, good air tightness performance, and ensures reliable isolation between the system and the atmosphere.
Vacuum isolation gate valve test pressure
nominal pressure |
test pressure/MPaSealtest |
||
Shell strength test |
Back Seal test |
Sealing test |
|
1.0 |
1.5 |
1.1 |
1.1 |
1.6 |
2.4 |
1.8 |
1.8 |
2.5 |
3.8 |
2.8 |
2.8 |
4.0 |
6.O |
4.4 |
4.4 |
6.4 |
8.6 |
7.O |
7.0 |
1O. O |
15.O |
11.O |
11.O |
Scope of use of vacuum isolation gate valve
product type |
Applicable Medium |
Temperature/℃ |
NKZ41H |
Water, steam, air |
≤425 |
NKZ41H(Y) |
Water, steam, air |
≤550 |
Main component materials of vacuum isolation gate valve
Part name |
Valve body and valve cover |
valve stem |
Ram |
Sealing surface |
stem nut |
filler |
fastener |
NKZ44H |
WCB |
2Crl3 |
25 |
H: Alloy steel |
Aluminum bronze |
Expanded composite graphite |
High quality carbon steel |
NKZ44 |
chromium molybdenum steel |
20CrlMo1VA |
chromium molybdenum steel |
Y: Hard alloy |
chromium molybdenum steel |
Main dimensions and weight of vacuum isolation gate valve
Nominal Diameter |
nominal pressure |
Main external dimensions and connection dimensions/mm |
valve |
Attached flange dimensions/mm |
||||||||||
L |
H |
D |
D1 |
D2 |
b |
f |
z-d |
W |
h |
D0 |
Dn |
|||
50 |
1.O |
250 |
345 |
160 |
125 |
1OO |
16 |
3 |
4-18 |
250 |
28 |
45 |
49 |
58 |
65 |
270 |
395 |
180 |
145 |
120 |
18 |
3 |
4-18 |
250 |
40 |
48 |
64 |
75 |
|
80 |
280 |
425 |
195 |
160 |
135 |
20 |
3 |
4-18 |
300 |
55 |
50 |
78 |
97 |
|
100 |
300 |
51O |
215 |
180 |
155 |
20 |
3 |
8-18 |
300 |
72 |
52 |
96 |
110 |
|
125 |
325 |
570 |
245 |
21O |
185 |
22 |
3 |
8-18 |
350 |
106 |
60 |
120 |
136 |
|
150 |
350 |
725 |
280 |
240 |
21O |
24 |
3 |
8-18 |
350 |
146 |
60 |
145 |
163 |
|
200 |
400 |
820 |
335 |
295 |
265 |
26 |
3 |
8-18 |
400 |
220 |
62 |
202 |
223 |
|
250 |
450 |
890 |
390 |
350 |
320 |
28 |
3 |
12-23 |
400 |
315 |
62 |
225 |
278 |
|
300 |
500 |
1070 |
440 |
400 |
368 |
28 |
3 |
12-23 |
450 |
398 |
65 |
303 |
330 |
|
350 |
550 |
1320 |
500 |
460 |
428 |
30 |
4 |
16-23 |
550 |
530 |
65 |
351 |
382 |
|
400 |
600 |
1450 |
565 |
515 |
482 |
32 |
4 |
16-25 |
550 |
690 |
65 |
398 |
432 |
|
450 |
650 |
1560 |
615 |
565 |
532 |
32 |
4 |
20-25 |
600 |
870 |
70 |
460 |
485 |
|
500 |
700 |
1720 |
670 |
620 |
585 |
34 |
4 |
20-25 |
650 |
1080 |
78 |
500 |
535 |
|
600 |
800 |
1880 |
780 |
725 |
685 |
36 |
5 |
20-30 |
700 |
1350 |
90 |
600 |
636 |
|
700 |
900 |
2085 |
895 |
840 |
800 |
40 |
5 |
24-30 |
750 |
1950 |
90 |
690 |
726 |
|
800 |
1OOO |
2590 |
101O |
950 |
905 |
44 |
5 |
24-34 |
800 |
2500 |
106 |
790 |
826 |
|
50 |
1.6 |
250 |
345 |
160 |
125 |
1OO |
16 |
3 |
4-18 |
250 |
28 |
48 |
49 |
58 |
65 |
270 |
395 |
180 |
145 |
120 |
18 |
3 |
4-18 |
250 |
40 |
50 |
64 |
75 |
|
80 |
280 |
425 |
195 |
160 |
135 |
20 |
3 |
8-18 |
300 |
58 |
52 |
78 |
91 |
|
100 |
300 |
51O |
215 |
180 |
155 |
20 |
3 |
8-18 |
300 |
75 |
52 |
96 |
110 |
|
125 |
325 |
570 |
245 |
21O |
185 |
22 |
3 |
8-18 |
350 |
110 |
60 |
120 |
136 |
|
150 |
350 |
725 |
280 |
240 |
21O |
24 |
3 |
8-23 |
350 |
150 |
60 |
145 |
163 |
|
200 |
400 |
820 |
335 |
295 |
265 |
26 |
3 |
12-23 |
400 |
223 |
62 |
201 |
223 |
|
250 |
450 |
890 |
405 |
355 |
320 |
30 |
3 |
12-25 |
450 |
326 |
68 |
253 |
278 |
|
300 |
500 |
1070 |
460 |
41O |
375 |
30 |
3 |
12-25 |
550 |
432 |
70 |
303 |
330 |
|
350 |
550 |
1320 |
520 |
470 |
435 |
34 |
4 |
16-25 |
600 |
572 |
78 |
351 |
382 |
|
400 |
600 |
1450 |
580 |
525 |
485 |
36 |
4 |
16-30 |
650 |
740 |
90 |
398 |
432 |
|
450 |
650 |
1560 |
640 |
585 |
545 |
40 |
4 |
20-30 |
700 |
955 |
95 |
450 |
485 |
|
500 |
700 |
1720 |
705 |
650 |
608 |
44 |
4 |
20-34 |
750 |
1195 |
98 |
500 |
535 |
|
600 |
800 |
1880 |
840 |
770 |
718 |
48 |
5 |
20-41 |
800 |
1455 |
105 |
600 |
636 |
|
700 |
900 |
2085 |
g1O |
840 |
788 |
50 |
5 |
24-41 |
850 |
211O |
11O |
690 |
726 |
|
800 |
1OOO |
2590 |
1020 |
950 |
898 |
52 |
5 |
24-41 |
950 |
2630 |
115 |
790 |
826 |
Main dimensions and weight of vacuum isolation gate valve
Nominal Diameter |
nominal pressure |
Main external dimensions and connection dimensions/mm |
valve |
Attached flange dimensions/mm |
||||||||||
L |
H |
D |
D1 |
D2 |
b |
f |
Z-d |
W |
h |
DO |
Dn |
|||
50 |
25 |
250 |
345 |
160 |
125 |
100 |
20 |
3 |
4-18 |
250 |
30 |
48 |
49 |
64 |
65 |
270 |
395 |
180 |
145 |
120 |
22 |
3 |
8-18 |
250 |
43 |
52 |
66 |
82 |
|
80 |
280 |
425 |
195 |
160 |
135 |
22 |
3 |
8-18 |
300 |
60 |
55 |
78 |
95 |
|
1OO |
300 |
510 |
230 |
190 |
160 |
24 |
3 |
8-23 |
300 |
79 |
62 |
100 |
117 |
|
125 |
325 |
570 |
270 |
220 |
188 |
28 |
3 |
8-25 |
350 |
114 |
68 |
125 |
144 |
|
150 |
350 |
725 |
300 |
250 |
218 |
30 |
3 |
8-25 |
350 |
157 |
72 |
151 |
172 |
|
200 |
400 |
820 |
360 |
310 |
278 |
34 |
3 |
12-25 |
400 |
243 |
60 |
201 |
223 |
|
250 |
450 |
890 |
425 |
370 |
332 |
36 |
3 |
12-30 |
450 |
345 |
85 |
253 |
278 |
|
300 |
500 |
1070 |
483 |
430 |
390 |
40 |
4 |
16-30 |
550 |
455 |
92 |
303 |
330 |
|
350 |
550 |
1320 |
550 |
4g0 |
448 |
44 |
4 |
16-34 |
650 |
615 |
98 |
351 |
382 |
|
400 |
|
1450 |
610 |
550 |
505 |
48 |
4 |
16-34 |
700 |
7g4 |
115 |
398 |
432 |
|
450 |
650 |
1560 |
660 |
600 |
555 |
50 |
4 |
20-34 |
750 |
1018 |
115 |
450 |
483 |
|
500 |
700 |
1720 |
730 |
660 |
61O |
52 |
4 |
20-41 |
800 |
1250 |
120 |
498 |
535 |
|
600 |
800 |
1880 |
840 |
770 |
718 |
56 |
5 |
20-41 |
850 |
1528 |
130 |
598 |
636 |
|
700 |
900 |
2085 |
955 |
875 |
815 |
60 |
5 |
24-48 |
900 |
2265 |
140 |
688 |
726 |
|
800 |
1000 |
2590 |
1070 |
990 |
930 |
64 |
5 |
24-48 |
1000 |
2847 |
150 |
788 |
826 |
Nominal Diameter |
nominal pressure |
Main external dimensions and connection dimensions/mm |
valve |
Attached flange dimensions/mm |
||||||||||||
L |
H |
D |
D1 |
D2 |
b |
f |
D6 |
f2 |
z-d |
W |
h |
DO |
Dn |
|||
50 |
4.O |
250 |
345 |
160 |
125 |
100 |
20 |
3 |
88 |
4 |
4-18 |
300 |
35 |
48 |
48 |
64 |
65 |
270 |
395 |
180 |
145 |
120 |
22 |
3 |
11O |
4 |
8-18 |
300 |
49 |
52 |
66 |
82 |
|
80 |
280 |
425 |
195 |
160 |
135 |
22 |
3 |
121 |
4 |
8-18 |
350 |
65 |
58 |
78 |
95 |
|
100 |
300 |
510 |
230 |
190 |
160 |
24 |
3 |
150 |
4.5 |
8-23 |
350 |
87 |
68 |
100 |
117 |
|
125 |
325 |
570 |
270 |
220 |
188 |
28 |
3 |
176 |
4.5 |
8-25 |
400 |
124 |
68 |
125 |
144 |
|
150 |
350 |
725 |
300 |
250 |
218 |
30 |
3 |
204 |
4.5 |
8-25 |
400 |
172 |
72 |
151 |
172 |
|
200 |
400 |
820 |
375 |
320 |
282 |
38 |
3 |
260 |
4.5 |
12-30 |
450 |
275 |
88 |
19g |
223 |
|
250 |
450 |
890 |
445 |
385 |
345 |
42 |
3 |
313 |
4.5 |
12-34 |
550 |
392 |
102 |
251 |
278 |
|
300 |
500 |
1070 |
51O |
450 |
408 |
46 |
4 |
364 |
4.5 |
16-34 |
650 |
515 |
116 |
301 |
330 |
|
350 |
550 |
1320 |
570 |
510 |
465 |
52 |
4 |
422 |
5 |
16-34 |
750 |
684 |
120 |
34g |
382 |
|
400 |
600 |
1450 |
655 |
585 |
535 |
58 |
4 |
474 |
5 |
16-41 |
850 |
902 |
142 |
396 |
432 |
Structure diagram of NKZ41H vacuum isolation gate valve:
Ordering process:
1. Fax the customer's purchase list, call for consultation, or email shweierdun@163.com
2. Received the customer's purchase list and provided the customer with valve model selection and quotation (price list)
3. Specific agreement: delivery time, special requirements, and other matters
Ordering Notice:
1. If the customer has special requirements for the product, the following instructions must be provided in the order contract:
a. Structural length;
b. Connection form;
c. Nominal diameter;
d. Product usage medium, temperature, and pressure range;
e. Testing, inspection standards, and other requirements.
2. Our factory can configure various driving devices according to specific customer requirements.
3. When the customer provides the determined valve type and model, the customer should correctly explain the meaning and requirements of the model, and sign the contract under the condition of mutual understanding between the supply and demand parties.
4. Futures and ordering customers are requested to first call and provide detailed information on the required valve model, specifications, quantity, delivery time, and location. And 30% of the total contract amount shall be prepaid, and the supplier shall prepare materials for production.