Hebei Emery Technology Co., Ltd
Home>Products>NOX analyzer - Nitrogen oxide analyzer (NOX) - Nitrogen oxide detector
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15830190109
  • Address
    2F, Building 5, Zone C, Fangyi Science Park, No. 313, the Pearl River Avenue, Shijiazhuang High tech Zone, Hebei Province, China
Contact Now
NOX analyzer - Nitrogen oxide analyzer (NOX) - Nitrogen oxide detector
Mainly suitable for gas boilers with a capacity of 20 tons/hour or less, it can store monitoring data for no less than one year and historical data fo
Product details

AMLNO200Type of combustionGas Boiler Nitrogen Oxide Tail Gas Analyzer (NOX Analyzer)



Project Background:

In order to promote the construction of ecological civilization, implement the spirit of document No. 177 issued by the Hebei Provincial Government, further deepen boiler pollution control, and reduce nitrogen oxide emissions, Beijing has completed the low nitrogen combustion transformation of all gas boilers, with nitrogen oxide emission concentration controlled within 30mg/m3 and total emissions reduced by 80%. The AMLNO200 gas boiler nitrogen oxide tail gas analyzer aims to ensure that the nitrogen oxide emissions of gas boilers meet the standards by improving the detection technology.


Scope of application:

The Emerson AMLNO200 gas boiler nitrogen oxide tail gas analyzer (NOX analyzer) is mainly suitable for gas boilers with a capacity of less than 20 steam tons per hour, low nitrogen combustion retrofit boilers, replacement of low nitrogen burner boilers, and overall replacement of boiler emissions of nitrogen oxide tail gas. The low nitrogen burner refers to the use of full range mixed burners, staged burners (with smoke recirculation devices), and other technologies for nitrogen oxide exhaust gas analyzers



System composition:

AMLNO200 analyzer host (required)

Gas sampling device (mandatory)

Oxygen content analyzer (mandatory)

Temperature, pressure, flow and humidity measuring instrument (optional)

Boiler operation status analysis (optional)

Sulfur dioxide analyzer (optional)

Smoke and dust analyzer (optional)



System features:

In line with national environmental trends and standards and regulations

Comply with the regulatory requirements of national and local environmental protection departments for gas boilers

Can store monitoring data for no less than one year and historical data for 5 years

Complies with the Hebei Province Boiler Air Pollutant Emission Standards

Real time detection of NOx, oxygen content, and temperature,

Real time Chinese display on TFT-LCD industrial touch screen

Optional SO2, smoke, dynamic pressure, static pressure, flow rate, humidity detection

Electronic refrigeration for water removal, multi-stage dehumidification and dust removal,

± 1 ℃ temperature control monitoring, removing the influence of temperature and humidity on the instrument

Continuously providing product technology upgrades and hardware expansion services in accordance with environmental policies

High penetration rate, with users covering 22 provinces and cities including Shanghai, Chongqing, Shandong, etc

Automatic back blowing and cleaning function, extending the service life of the instrument

M-BUS signal output, other signals can be customized

Scalable collection of operating status of gas boilers

Emerson's Top 10 Domestic Segmented Industries



Monitoring parameters:

Monitored Parameters

measuring range

resolution

accuracy

measuring principle

Oxygen content (O2)

0~25Vol.%

0.1%

±0.5%

electrochemistry

Nitric oxide (NO)

0~100ppm

0.5ppm

±2%FS

electrochemistry

Nitrogen dioxide (NO2)

0~500ppm

0.5ppm

±2%FS

electrochemistry

Sulfur dioxide (SO2)

0~20ppm

0.2ppm

±2%FS

electrochemistry

smoke and dust

0~50mg/m3

1mg/m3

±2%FS

Laser backscattering

temperature

-40~85℃

0.01℃

±2.5%FS

Pt100 sensor

humidity

0~99%RH

0.04%RH

±3%RH

Semiconductor sensors

dynamic pressure

0~1000Pa

1Pa

±2.5%FS

differential pressure sensor

static pressure

80~120kPa

0.1kPa

±2.5%FS

Absolute pressure sensor

velocity of flow

0~40m/s

0.1m/s

±2.5%FS

differential pressure sensor


Technical indicators:


  • Sensor lifespan: 2 years for electrochemical sensors, 5 years for infrared and PID sensors
  • Working temperature:- 20~+70℃
  • Storage temperature:- 40~+70℃
  • Working humidity: ≤ 10% -95% RH non condensing
  • Working mode: Can work continuously
  • Accuracy: ±2%F.S
  • Linear: ± 2% F.S
  • Zero drift: ± 2% F.S
  • Display: Embedded LCD touch screen
  • Response time:< 60s
  • Gas sampling flow rate: 500ml/min
  • Sampling method: pump suction
  • Power supply mode: Municipal AC220 50Hz 1.0A