1. Due to the fact that the cooling and lubrication of magnetic pump bearings rely on the medium being transported, idle running is prohibited, while avoiding spatiotemporal load running caused by restarting after a power outage during operation.
2. If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet; if it contains ferromagnetic particles, a magnetic filter should be added.
3. The ambient temperature of the pump during use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.
Point:
(1) Smooth liquid transportation, no pulsation, low vibration, and low noise.
(2) Has strong self-priming performance.
(3) Proper selection of component materials can transport various corrosive media and can be used at temperatures up to 200 ℃.
(4) The inner and outer rotors have the same direction of rotation, with minimal wear and a long service life.
(5) The speed of the pump is linearly related to the flow rate, and the speed can be adjusted appropriately to change the flow rate of the pump.
(6) Do not use high viscosity and viscosity media for transportation.