Natural gas biogas hygrometer
Cantilever beam sensor
Product details


The first generation TDLAS analyzer performs fully automatic, online humidity measurement in natural gas and biogas with compositional changes. The OptiPEAK TDL600 laser analyzer adopts the principle of laser spectral absorption and signal processing technology, mainly used for measuring humidity in natural gas. Adopting non-contact measurement technology with minimal maintenance costs.

Highlights

  • D-MET system: Gas composition is set before leaving the factory, and biomethane and shale gas are mixed
  • Range as low as 1 ppmV
  • Acid resistant gas environment
  • Easy installation
  • Low cost maintenance
  • EExd explosion-proof shell, compliant with IECEx, ATEX and cMETus certifications
  • Complete sampling system
Condumax II

TECHNICAL INDEX

measurement TDLAS
Range of measurement 1 ppmV to 1000 ppmV
accuracy ± 1% reading>100 ppmV
±1ppmV <100 ppmV
repeatability <1 ppmV (long-term stable<0.1 ppmV/year)
Measurement limit 1 ppmV
Measurement unit ppmV, lb/MMSCF, (ISO18453 or IGT#8),
mg/Nm3, dew point °C or °F
response speed Optical feedback 0.2s
Refresh display for 2 to 3 seconds
operation temperature -20 ° C to+55 ° C
Electrical parameters
voltage 110 V AC or 230 V AC 50/60Hz
power supply Indoor installation: 80W
Outdoor installation: 180W
analog signal Input: 2 x 4-20 mA user configurable
Output: 3 x 4-20 mA, 3 alarms 250 V AC, 10A
digital communication RS485 ModBus RTU
data record Users can choose a sampling period from 10 seconds to 1 day to record relevant parameters
Local display 4.3 "LCD touch screen
electrical interface 3 x M20
check
Factory mode 3 points, tracing back to NPL and NIST
Recommended verification According to user needs
Mechanical indicators
Sample gas flow rate 1 Nl/min sample gas, 1 to 5 Nl/min
Sample gas filtration bypass
intake pressure Maximum 2000 PSI (138 barg)
Exhaust pressure Exhaust port 0.7 to 1.4 bara, filter bypass
Up to 3 barg maximum
work environment Indoor/Outdoor -20~60 ° C High 95% RH
Shell standard/packaging Aluminum alloy, explosion-proof casing, IP66,NEMA 4
Gas path port 1/4” NPT (F)
weight 40kg (88lbs) (without sampling system)
Sampling system casing 304L or 316L stainless steel
Dangerous Place Certification ATEX: II 2G Ex d ib op is IIC T5 Gb Ta -20 ° C to+60 ° C
IECEx: 2G Ex d ib op is IIC T5 Gb Ta -20 ° C to+60 ° C
CMETus: Class 1, Div 1, Groups A, B, C, D, T5, Tamb -20 ° C to+60 ° C, IP66
TC TR Ex: 1 Ex d ib op is IIC T5