Natural gas liquefied gas artificial gas calorific value analyzer for C1~C5 detection in natural gas gas gas chromatograph
This model is designed with two relatively independent chromatographic analysis systems with thermal conductivity detectors, equipped with a complete
Product details
details

Performance characteristics

Domestically produced next-generation high-performance and high stabilitygas chromatographBased on this, it runs reliably and stably.

Widely applicable, it can be used for full component analysis of various types of natural gas.

Injection method: Manual six way valve injection, two valves can be connected in series for simultaneous injection or separate injection.

Two detector signal channels can be used simultaneously or separately.

Analyze spectrum storage, data processing, and report printing at will.

It can calculate technical parameters such as calorific value, white number, and relative density of natural gas.

Performance characteristics

Injection port flow rate, chromatographic column carrier gas flow rate, detector gas flow rate, precision control

Multiple injection ports can be configured: packed column injection port (with spacer blowing, can be connected to large-diameter capillary column), splitter/Non split capillary injection port, program-controlled cold column head injection port, volatile component series connection injection port (specially equipped with sample pretreatment devices such as headspace/sweep capture/thermal desorption);

Detector Design for Industry *

The amplification plate with special ceramic treatment is stable during humid seasons, automatically ignites, and has automatic protection against hydrogen leakage, making it safe and reliable.

Precise control program temperature rise and furnace temperature, precise furnace temperature tracking design

The internal control accuracy of the furnace is less than0.01℃; The temperature difference between internal points shall not exceed 1 ℃; Rapid heating and cooling, with a programmed heating rate of 120 ℃/min; Balance time of 10 seconds; Cooling time (300 ℃ to 50 ℃) for 6 minutes; The accuracy of temperature control (with a difference of less than 0.3 ℃ from the actual temperature).

Fully imported valve configuration system

*More equipped8 valves (four-way valve, six way valve, ten way valve, and liquid injection valve optional); Automatic control and sequential operation; 0 leakage blowing technology; High speed switching solenoid valve has a long service life (1 million times, 10mS).

Separated columns oven

In a multi column chromatography system, different column operating temperatures can be set separately to achieve separation efficiency for each column;

Convenient implementation of pneumatic cutting technology

It can achieve multidimensional chromatography function to separate and analyze complex samples, and can realize the blowback function of the chromatography column to save analysis time and cycle;

TECHNICAL INDEX

column oven

Temperature Control Range

Room temperature+5 ℃~450 ℃;

Temperature setting accuracy

0.1℃

*Program heating speed

60℃/min

Cheng Sheng's order

8th order program temperature rise

Cheng Sheng rate

0.1~120 ℃/min (incremental 0.1 ℃)

*Running time

999.99 minutes

Runable column loss compensation (dual channel)

heating zone

6 independent control heating zones (excluding furnace temperature control, two injection ports, two detectors, and two auxiliary heating zones)

Auxiliary heating zone * operating temperature

300℃

detector

Hydrogen flame ionization detector FID

*Usage temperature

450℃

detection limit

≤2.5pgC/s [n-C16]

Dynamic linear range

≥107(±10%)

Data collection frequency

*100Hz

Compatible with packed columns and capillary columns

Thermal conductivity detector TCD

*Usage temperature

400℃

detection limit

<400pg propane/mL, helium

Dynamic linear range

105(±5%)

Data collection frequency

*100Hz

Single filament micro pool design; Compatible with packed columns and capillary columns

Experimental diagram

1. Mixed gas



undefined

2. Dry gas

天然气-干气

instrumentconfiguration

Serial Number

product name

Model/Specification

quantity

1

Gas chromatograph (TCD, packed column injection system, programmed temperature rise, back door)

GC-9280

1 unit

2

Chromatography workstation

PR-3000

1 unit

3

hydrogen generator

PRH-300

1 unit

4

sampling bag

2L dual switch

5 pieces

5

Specialized chromatographic column

1 piece

6

Standard gas

1 bottle

7

Computer and Printer

1 set

Update time: September 1, 2020 8:53:10