Shanghai Xinweisheng Pharmaceutical Machinery Co., Ltd
Home>Products>Negative pressure weighing hood
Negative pressure weighing hood
The negative pressure weighing hood series products are suitable for the weighing, sampling, packaging, and batching of highly active and toxic produc
Product details
Performance characteristics

The main structure of the equipment is made of stainless steel material, and the surface has been polished to create a beautiful and elegant appearance. The surface is smooth and flat, making it easy to clean
The left side of the equipment workbench is equipped with a double-layer safety glass window, which is conducive to light collection and operation
The electrical control part adopts programmable logic controller (PLC) and touch screen, with variable frequency speed regulation for air flow
Adopting a unique three zone ventilation principle, it achieves the effect of isolating the operating area from the external environment with an air curtain
The operator is located outside the operating area, avoiding interference with the airflow and preventing harmful objects from harming people and the environment
The required air flow rate for the entire machine is small, which reduces energy consumption and extends the service life of the filter. The noise level is ≤ 70db
The air flow velocity in the operating area is low, controlled between 0.1-0.4m/s, ensuring the accuracy of the studio operation
◆ Small processing and cleaning area, easy to maintain and clean
The operating area can achieve ISO level 5 cleanliness
Using fewer and smaller filters reduces maintenance costs
The exhaust/circulating airflow flow detector is equipped with an alarm, which will sound and light if the flow rate is too fast or too slow. The air guiding system ensures that particles can be firmly retained even in very gentle airflow, in accordance with EN 14175-3 and ISPE SMEPAC guidelines.
The cleaning air curtain (area 3 in the figure below) separates area 1 and area 2, so it acts like a screen, preventing turbulence and mixing between areas 1 and 2. Particles cannot flow between region 1 and region 2. The partition cleaning air curtain formed by the special outlet crossbar has to some extent replaced the role of the isolation air plate. The airflow velocity in this formed area (Area 3) is significantly different from the airflow velocity in the other two areas, thus playing a role in isolation and stability. The final result is that the air, foreign gases, suspended solids, etc. in Zone 1 cannot enter Zone 2 through Zone 3, and the ambient air (including components) in Zone 2 cannot enter the working area of Zone 1.

technical parameter

model Circulating air flow rate Exhaust flow rate Studio air velocity Deep working area Worktable width Worktable height Capacity/Power Supply Maximum external dimensions Whole machine weight
Negative pressure weighing hood 1800m3/h 300m3/h 0.1-0.4m3/s 885mm 580mm 950mm 1.2KW 380V/50HZ 1435X1500X3000 mm 600 Kg