The wiring diagram is as follows:
2. Set the following before powering on:
(1) Switch the EC power supply behind the tester to the INT option.
(2) Set the MODE on the front board of the tester as the encoder for testing, and the corresponding table for the encoder is as follows:
(3) Turn the switch in the lower left corner of the front version of the testing machine to Analog Check.
(4) Plug in a 5V power supply in the later version.
(5) Provide a speed higher than 800 revolutions per minute for the test motor to operate through an external coupling.
(6) Turn on the power of the testing machine to ON.
3. Testing:
(1) Press the ECPOWER button to provide power to the encoder.
(2) Simultaneously press the SHIFT+F3 keys, and the testing machine will start testing. After the test is completed, the results will be displayed. The result comparison is shown in the following figure:
The error code is as follows: