Nitrogen mass flow meter
Thermal gas mass flow meters can be used in the field of process control. It does not require temperature and pressure compensation and can directly m
Product details
overview

Nitrogen mass flow meters can be used in the field of process control. It does not require temperature and pressure compensation and can directly measure the mass flow rate of the fluid. Its prominent feature is: no moving parts; Low pressure loss; Wide range ratio; High precision; High reliability; Easy to install and operate. Can fully replace orifice plates and differential pressure flow meters in all fields.

Working principle

The HY-RSL nitrogen mass flowmeter adopts the principle of thermal diffusion, which is a technology with excellent performance and high reliability under harsh conditions. Its typical sensing elements include two thermal resistors (platinum RTDs), one is a velocity sensor and the other is a temperature sensor that automatically compensates for gas temperature changes. When these two RTDs are placed in a medium, the velocity sensor is heated to a constant temperature difference above ambient temperature, while the other temperature sensor is used to sense the temperature of the medium. The mass flow rate of gas passing through the velocity sensor is calculated based on the heat transfer of the sensing element. As the gas velocity increases, the amount of heat transferred from the sensor to the medium also increases.

(1) All products are designed with no moving parts to prevent sensor blockage caused by dirty media or media particles.

(2) Wide range ratio of 100:1, sensitive to low flow without the need for multi-stage measurement, suitable for various ranges on site.

(3) Almost no pressure loss, overcoming the disadvantage of traditional differential pressure method that cannot measure due to low pipeline pressure.

(4) Resolve various practical issues for users, such as inadequate installation of straight pipe sections, changes in composition, poor measurement results, etc. The component changes can be corrected, the sensor can be cleaned online, and the insertion length can be adjusted arbitrarily.

(5) Sensors can be selected/multi-point to meet various usage requirements and high-precision measurements.

(6) Sensor insertion or online installation reduces installation costs and is suitable for measuring various pipe diameters.


Product Features

1. Setting of different gas coefficients

2. Display zero point reset

3. Correction of output analog quantity

4. Multi point nonlinear curve correction

5. Wide range ratio greater than 100:1

6. Large caliber and small flow measurement have higher accuracy

7. On site instrument settings can be made

8. Encapsulated sensors with near zero pressure loss

9. Not sensitive to vibration

10. The requirements for straight pipe sections are relatively small

11. Measurement values are independent of pressure, true mass flow detection

12. Using expert algorithms to achieve high precision and stability of instruments

13. Response time less than one second

14. LCD display with instantaneous cumulative dual display, no need to switch

Technical Parameter

Accuracy:

±1-2.5%

Repeatability:

0.2% full scale

Temperature range:

Environmental temperature -20 ℃ -70 ℃

Medium temperature:

-20 ℃ -200 ℃ or -20 ℃ -350 ℃

Power supply:

24VDC/220VAC

Analog output:

4-20mADC

Response time:

≤ 1 second

Temperature coefficient:

0.05%/℃

Communication interface:

RS485

Online display:

LCD display instantaneous and cumulative flow rate

Process pressure:

≤ 4.2MPa (if the pressure is greater than this, customization needs to be negotiated with our company)

Process connection:

Flanges, if other installation methods are required, please consult with our company in advance for customization

Explosion proof grade:

ExdIICT4

Protection level:

Sensor IP67, transmitter IP65

Applicable medium:

Gas without moisture

Measurement range:

0.05-80m/s (standard state is 20 ℃, 0.10133MPa)

Sensor material:

The standard is 316L; Ha C; tantalum

Probe rod material:

The standard is 1Cr18Ni9Ti; 316L; Ha C; tantalum

Shell material:

Aluminum castings with powder coating for installation in hazardous areas

Electrical interface:

M20×1.5

Warranty period:

Within one year of the normal use period of the product

Pressure loss:

For pipelines with a diameter greater than DN80, they can be ignored