Non invasive pulse oximeter for small animals (blood oxygen saturation meter)
MouseOx non-invasive pulse oximeter measures the blood oxygen saturation, pulse rate, respiratory rate, pulse amplitude, and respiratory amplitude of
Product details


MouseOxNon invasive pulse oximeter measures the blood oxygen saturation, pulse rate, respiratory rate, pulse amplitude, and respiratory amplitude of small animals (such as mice, rats, guinea pigs, rabbits, etc.) in a non-invasive manner. All measurements are taken through a non-invasive sensor.

Function:
Intraoperative monitoring of small animal surgery (ensuring appropriate anesthesia depth and preventing hypoxia during surgery)
A non-invasive sensor obtains multiple vital signals (arterial oxygen saturation, heart rate, respiratory rate, pulse amplitude, respiratory amplitude)
Record of cardiopulmonary function parameters
Output simulated data

MouseOx
The system consists of three components:MouseOxEquipmentStarrLink the analog output module and Starr binding tube.

Cardiopulmonary monitoring parameters

Pulse frequency (heart rate)
Monitor within the range of 90 to 900 BPM (beats per minute, BPM)

Blood oxygen saturation
Monitoring range: 0% to 100% arterial oxygen saturation;
Monitoring error:<1.5% across the entire monitoring range;
Monitoring reaction time: Arterial oxygen saturation is reported to the user in real-time, and after each heartbeat, the screen refreshes 0.72 seconds to display all measured arterial oxygen saturation.

Respiratory rate:
Monitoring range: 25 to 450 times per minute
Monitoring reaction time: Respiratory rate is reported to the user every 1.7 seconds, and the mobile report value is the average of 10 breaths

Pulse amplitude:
Non traumatic monitoring of pulse filling to estimate changes in blood flow
Monitoring range: microvessels with an inner diameter of 0 to 800 micrometers;
Monitoring error:<2.4% across the entire monitoring range;
Monitoring reaction time: Pulse filling degree is reported to the user in real-time. After each heartbeat, the screen refreshes 0.72 seconds to display all measured pulse filling degrees.

Respiratory amplitude (Movement of breath)
Non traumatic monitoring of changes in animal respiratory amplitude
Monitoring range: 25 to 450 times per minute
Monitoring reaction time: Respiratory rate is reported to the user every 1.7 seconds, and the mobile report value is the average of 10 breaths

Verified accuracy

The following is a comparison between the measurement results obtained using invasive blood gas sampling and non-invasive MouseOx measurement.

Multi functional sensor


CollarClip used under non anesthetic conditions ™ a sensor


ThroatClip Sensor


Mouse leg sensor


Rat Foot Sensor


Compatible with sensors under MRI conditions