Online manganese ion analyzerAnalects: Mn concentration (can also monitor total manganese)
Measurement range Mn: 0-10ppm (expandable range)
Principle: Under certain pH conditions, manganese ions can be instantly oxidized by potassium periodate into high valence manganese ions to produce stable colors. The absorbance can be measured at a specific wavelength, and a standard curve can be drawn to determine the concentration of the sample.
Online manganese ion analyzerhost
Adopting microcomputer control processing unit:
Storage and logical operation functions
♦ Touch screen:
Record data and files, save values and results, and store historical records
♦ Network function:
Communication and transmission with local area network, can be remotely operated to view data through 4G connection
♦ 24V DC power supply and power supply failure:
24V DC power supply and automatic saving of parameters, historical records, and clock in case of power failure
♦ Data collector:
Single chip data acquisition values
♦ Data output function:
Ethernet (standard), USB serial port interface, RS232, RS485 (MODBUS communication protocol)
♦ Signal status:
Calibrate passive points, maintain contacts, remote/local contacts, start analysis, reset analysis, wait analysis, pause analysis.
♦ Analog data output:
High load of 600 ohms, 4-20mA (current blocking) can provide two output quantities
♦ Alarm function:
Machine malfunction alarm and data upper and lower limit alarm
♦ Environment:
Clean the room with a relative humidity of 2% -95% (no condensation),
10-30 ° C+/-4 ° C deviation (50 ° F-86 ° F+/-7.2 ° F deviation)
♦
Shell:
Protection level IP65 (compliant with DIN40050)
Size (Width 600 x Length 450 x Height 1500MM)
Shipping 40kg, machine shell grounding wire device
♦ Pipeline:
Peristaltic pump, micro pump, diaphragm pump, injection pump, discharge, instrument air, discharge
♦ Cleaning and calibration:
Mineral free purified water/distilled water is used for calibration, cleaning, dilution, etc
basic operation
The analyzer has successfully passed a series of tests for installation and setup. During installation, simply connect the reagent, sample, waste liquid pipeline, and power cord, and set the parameters to start. Automatic calibration, automatic cleaning, automatic testing, and automatic data saving. Long term self-control, low maintenance, low operating costs, fully automatic operation, low chemical consumption, short preparation time, simple maintenance, no need for special electrician training.