Hengteya brand organic solvent Karl Fischer titration instrument adopts Karl Fischer coulometric titration method, also known as Karl Fischer coulomet
Product details






Hengteya brandOrganic solvent Karl Fischer moisture detectorThe Karl Fischer coulometric titration method, also known as Karl Fischer coulometric titration or Karl Fischer coulometric titration, is an internationally recognized method for detecting trace amounts of moisture in samples. The testing accuracy of 1ppm can meet the high requirements of various factories and laboratories for moisture accuracy. It has been widely used in departments such as power, petroleum, chemical, pharmaceutical, energy, scientific research, and education, and is a fully automatic moisture analyzer.
Hengteya brand organic solvent Karl Fischer moisture detectorAdopting a color LCD touch screen, mobile navigation, full Chinese menu, touch operation, clear at a glance, easy to operate. The instrument adopts dual CPUs, greatly improving the computational efficiency of testing. It is equipped with a large capacity data storage program for easy access to historical testing data, and a built-in micro printer can print out data at any time. Hengteya's instrument has multiple built-in calculation formulas. After selecting the appropriate formula for testing, it directly displays the percentage or ppm of moisture content. The instrument comes standard with dual platinum electrodes, which have high sensitivity and more accurate test results. The instrument has good sealing performance, avoiding the situation where the instrument cannot reach the endpoint due to high humidity in the external environment. The blank current microprocessor of the instrument can also eliminate the influence of the closed environment, allowing the reagent to quickly reach equilibrium. It is a multifunctional intelligent integrated instrument.



Hengteya brand
Organic solvent Karl Fischer moisture detectorTechnical parameters:
Model: HTY-H6
Display mode: 10 inch color LCD touch screen display
Measurement method: Karl Fischer Coulombic titration
Measurement range: 0.01 micrograms of water -200 milligrams of water
resolving power: 0.01ug water
Water content range: 0.0001%(1ppm)— 100%
Accuracy: When the water content is between 2 micrograms of water and 1000 micrograms of water, the error is ≤± 2ug,
When the water content is above 1000 micrograms of water, the error is ≤± 0.2% (excluding injection error)
Electrolysis speed: ≤ 2.4mg water/min
Electrolytic current: 0-430mA
Endpoint indication: Screen display/sound warning/print output/endpoint light prompt
Blank processing: The blank current microprocessor automatically controls compensation to ensure accurate deduction of blank during the 10 minute sample enrichment time
Drift compensation: The microprocessor automatically calculates and compensates
Calculation formula: Built in 5 calculation formulas
Data input: Touch screen operation input
Sample Number: User
Data storage: 1000 items
Printing function: Built in embedded thermal printer, ready to print anytime
Print content: Ug/ppm/mg/L/sample number/experimenter/date
Sample addition method: Liquid sampler or solid sampler
Calibration method: Deionized water calibration
Mixing method: Electromagnetic stirring
Mixing system: Manual adjustment, infinitely variable speed
Electrode material: High purity platinum electrode
Standard accessories: One large tank bottle, one electrolytic electrode, one measuring electrode, one Karl Fischer reagent bottle, one injection plug, one glass plug, one stirrer, one 0.5ul injection needle, one 50ul injection needle, one 100ul injection needle, one 1ml injection needle, one customized needle, one drying tube, one bag of drying particles, one bag of silicone gasket, one box of vacuum grease, and one power cord
External functions: Can connect to a computer, work both online and independently
Self checking function: The internal microprocessor function of the instrument automatically detects instrument faults
Calendar/Clock: Analyze time and date display (without losing power)
Power consumption: <40W
Dimensions (length * width * height): 430*350*190mm
Usage environment: Temperature 0-40 ℃, humidity<85%
Using power supply: Voltage 220V ± 10%, frequency 50HZ ± 2.5HZ
Weight: About 7.5Kg


Hengteya brand organic solvent Karl Fischer moisture detectorScope of application:

liquid Pharmaceutical industry: raw materials for traditional Chinese and Western medicine, etc
Pesticide industry: soluble powders, emulsions, emulsions, creams, pastes, oils, etc
Petroleum and power industry: insulation oil, transformer oil, hydraulic oil, coal tar, etc
Chemical industry: acids, alcohols, benzenes, phenols, ethers, organic solvents, etc
Other industries: lithium batteries, electrolytes, cosmetics, etc
solid Solid substances with good solubility, such as various inorganic salts and citric acid
gas Natural gas, liquefied gas, fluorocarbons, butadiene and other gases


Hengteya brand
Organic solvent Karl Fischer moisture detectorProduct specifications:
1. GB/T 6283-2008 Determination of moisture content in chemical products Karl Fischer method
2. ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
3. GB/T 7600-1987 Determination of Moisture Content in Operating Transformer Oil (Coulombic Method)
4. ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
5. ASTM D6304-2007 Karl Fischer coulometric titration method for determining water content in petroleum products, lubricants, and additives
6. ISO 10337-1997 Determination of Moisture in Crude Oil Karl Fischer Coulombic Titration Method
7. GB/T 11146-2009 Determination of Crude Oil Water Content Karl Fischer Coulombic Titration Method
8. GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use
9. GB/T 5074-1985 Method for determination of moisture content in coking products by microcoulometry
10. GB/T 6023-2008 Determination of Trace Water in Butadiene for Industrial Use Karl Fischer Coulombic Method
11. GB/T 7376-2008 Determination of Trace Moisture in Fluoroalkanes for Industrial Use Karl Fischer Method
12. GB/T 18619.1-2002 Determination of Water Content in Natural Gas Karl Fischer Coulombic Method
13. SH/T 0246-1992 Determination of Water Content in Light Petroleum Products (Electricity Method)
14. SH/T 0255-1992 Method for determination of moisture content in additives and lubricating oils containing additives (electric method)
15. ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
16. ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
17. ASTM D6304-2007 Standard for Determination of Water Content in Petroleum Products, Lubricants, and Additives by Karl Fischer Coulombic Titration
18. GB/T11133 Determination of Water Content in Liquid Petroleum Products (Karl Fischer Method)
19. Surface active agents - Determination of moisture content (Karl Fischer method)
20. GB10670-1989 Determination of Trace Moisture in Fluoromethane for Industrial Use Karl Fischer Method


Hengteya brandOrganic solvent Karl Fischer moisture detectorFunctional features:
1. Adopting a composite control system of microcontroller and computer for intelligent analysis and measurement;
2. 65K color 10 inch Chinese touch screen (resolution 800 * 600 pixels) display, mobile navigation guidance, easier operation;
3. The surface of the instrument is treated with electrostatic spraying, which is corrosion-resistant and easy to clean;
4. (Optional) Practical auxiliary functions that can connect the "electronic balance" to instrument data communication and processing;
5. The blank current microprocessor automatically controls compensation, and the reagent can quickly reach equilibrium state;
6. 0-430mA high electrolysis current, high detection sensitivity and fast analysis speed;
7. Powerful storage function, automatic storage of 1000 measurement results, and easy access to historical records at any time;
8. The instrument automatically measures the sample and displays the analysis results, and can automatically calculate the average value of multiple measurements of the sample;
9. Automatically calculate and print content such as ug/ppm/percentage content/mg/L/sample name/experimental date, etc;
10. It can be connected to laptops and desktop computers through USB, compatible with Windows XP and Windows 7 system operations, and enables network management;
11. The perpetual calendar function includes year, month, day, week, hour, minute, and second, which are automatically stored after power failure and will not be lost for 10 years;
12. Multiple language display operation, instrument program can be upgraded when national standards are revised.



Hengteya brand
Organic solvent Karl Fischer moisture detectorOperation steps:
1. After installing the instrument accessories according to the instructions, turn on the instrument;
2. Set parameters according to the instructions, select different setting items, and press the confirm button to save after selection;
3. Reagent equilibrium. Inject an appropriate amount of pure water into a 50 microliter sampler to neutralize any excess water in the reagent;
4. Instrument calibration. Using a 0.5ul sampler to extract 0.1ul of pure water for injection, the displayed result should be "100 ± 10ug (excluding injection error)". If the displayed result is within the error range, sample measurement can be performed.
5. Sample determination. After pressing the start button to inject the sample, the instrument will automatically perform the test. After the test is completed, a beep alarm will sound and the display screen will indicate "Test completed".



Hengteya brand
Organic solvent Karl Fischer moisture detectorprecautions
1、 Cannot display normally
Please check if the power connection wire, fuse, and power switch of the instrument are functioning properly.
2、 The instrument displays iodine
1. Evaluate whether the reagent is over iodine. If so, use a 0.5 microliter sampler to extract 0.2-0.4 microliters of water and inject it. Do not use an injector of 50 microliters or larger for injection.
2. Check whether the platinum wire at the bottom of the measuring electrode is connected together, causing a short circuit.
3、 The instrument shows an open circuit
Check if the measuring electrode is in good contact and re insert it firmly. Check if the connecting wire is broken.
4、 Open electrolysis without counting
Check if the electrolytic electrode is in good contact, unplug and plug it again, and check if the connecting wire is broken.
5、 Electrolysis does not end
Check if the reagent has expired.



Enjoy a one-year free warranty and lifetime maintenance from the date of purchase;
7-day no reason return and exchange, 24-hour instant response;
One on one technical guidance, allowing you to have no worries after purchasing;
National free consultation hotline: 400-8821-087.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!