Overview of Regulating Control Instruments
Brief introduction
Xiamen Yudian has accumulated nearly30 years of development and production experience. The products include regulating control instruments, measurement display alarm instruments, power instruments, intelligent flow integrators, split type paperless recorders, human-machine interface touch screens, rail mounted instruments, and PLC and AIDCS intelligent distributed control systems. Yudian's control instruments include multiple precision series of different levels, with an accuracy of 0.05 level (AIJ type), covering a wide range of high, medium, and low-end products, and can be used to accurately control temperature, pressure, flow, etc. In high-end temperature control fields such as crystal growth, superconducting materials, and precision experimental equipment, it can replace Japanese, European, and American series instruments; In the fields of ceramics, pharmaceuticals, glass, building materials, metallurgy, heat treatment, chemical engineering, rubber machinery, packaging machinery, food machinery, and various ordinary electric furnaces and ovens, Yudian's high-end energy-saving temperature controllers can improve the stability of customers' products while saving about 1-5% of energy consumption compared to ordinary precision temperature controllers, reducing customers' production costs and CO2 emissions.
2、 Product Features
1. 'Fever level' components achieve low power consumption, high stability, and low failure rate
2. AI artificial intelligence algorithms automatically adapt to different control objects
3. Modular technology, more flexible functional configuration
4. AIBUS communication is 2-10 times faster than MODBUS
5. Module power self isolation technology, suitable for complex working conditions
6. Program control and curve fitting technology, powerful functionality
7. 380VAC protection at the power supply end effectively protects the instrument
8. Customize non-linear input
3、 Main technical parameters
1. Enter specifications
Thermocouple:K. S, R, E, J, T, B, N, WRe3-WRe25, WRe5-WRe26, etc
Thermal resistance:Cu50、Pt100
Linear voltage:0-5V, 1-5V, 0-1V, 0-20mV, 0-10mV, 0-500mV, etc
Linear current:0-10mA, 0-20mA, 4-20mA, etc
Expansion specifications:Allow users to customize an additional input specification while retaining the above input specifications
Measurement accuracy:Multiple levels including 0.05, 0.1, 0.2, 0.25, and 0.3 (note: thermocouples should be compensated with an external Cu50 copper resistor, and an additional ± 1 ℃ compensation error will be added during internal compensation)
Temperature drift:Multiple levels of 30PPM/℃, 80PPM/℃, 100PPM/℃, 120PPM/℃
2. Output specifications
Relay contact switch output (normally open+normally closed):250VAC/1A, 250VAC/2A, or 30VDC/1A
Thyristor contactless switch output (normally open or normally closed):100-240VAC/0.2A (continuous), 2A (20mS instantaneous, repeat period greater than 5S)
SSR driving voltage output:12VDC/30mA (used to drive SSR solid-state relays)
Thyristor triggered output:Can trigger 5-500A bidirectional thyristors, 2 unidirectional thyristors connected in anti parallel, or thyristor power modules
Linear current output:0-10mA or 4-20mA can be defined (output voltage ≥ 10.5V when installing X3 module; output voltage ≥ 7V for X5 module)
Communication method:RS232、RS485
Communication baud rate:1200bps~19200bps
Feed output:Multiple specifications including 5V, 10V, 12V, 24V, etc
3. Control method
Position control:ON/OFF control
PID control:Standard PID regulation, AI artificial intelligence APID regulation
4. Electromagnetic compatibility
IEC61000-4-4 (Electric Fast Transient Pulse Group) ± 4KV/5KHz, IEC61000-4-5 (Surge) 4KV, and no instrument crashes or I/O misoperation under 10V/m high-frequency electromagnetic fields, with measurement value fluctuations not exceeding ± 5% of the range
5. Isolation and voltage resistance
The voltage between the power supply terminal, relay contact, and signal terminal is ≥ 2300V; Isolated weak current signal terminals with a voltage of ≥ 600V between them
6. Power supply
100~240VAC,- 15%,+ 10%/50-60hZ; Or 24VDC/AC-15%+ 10%
7. Usage environment
Temperature: -10 ℃ to+60 ℃; Humidity: ≤ 90%RH
4、 Introduction to Common Module Functions
Yudian adopts a modular approach that allows customers to install their own instruments to form the input/output of the instruments. By installing different modules, the functions of the instruments can be flexibly configured to "customize" their ideal instruments. At the same time, the manufacturer also achieves mass production, fast delivery, and zero product inventory, providing customers with products with higher performance/price ratios. There are dozens of modules available for customers to choose from, including various analog and switch input and output modules, communication and power modules, etc.
1. Communication interface module
SOptoelectronic isolation RS485 communication module (using internal 12V isolation power supply of the instrument)
S1Optoelectronic isolation RS485 communication module (using internal 24V isolation power supply of the instrument)
S4Communication module with built-in isolated power supply (does not occupy the internal power supply of the instrument)
RRS232 communication/printing module
2. Analog output module
X3Optoelectronic isolation current output module (using internal 12V isolation power supply of the instrument)
X31Optoelectronic isolated linear voltage output module (using an internal 12V isolated power supply of the instrument)
X5Optoelectronic isolation current output module with built-in isolation power supply (does not occupy the internal isolation power supply of the instrument)
3. Voltage output module (for external sensor/low-power device power supply)
V5/V10/V12/V24Isolated 5V, 10V, 12V, 24V DC voltage output (using internal 24V isolation power supply of the instrument)
U5Non isolated 5V DC voltage output
4. Switching output module
GSolid state relay drive voltage output module
G1Energy saving non isolated SSR driving voltage output module
G5Dual channel solid-state relay driving voltage output module
L0Large volume and large capacity relay contact switch output module (suitable for alarm)
L1Large volume and large capacity relay contact switch output module (suitable for control)
L2Small volume relay contact switch output module
L3Two channel large volume and large capacity relay contact switch output module
L31One normally open and one normally closed large volume and large capacity relay contact switch output module
L4Small volume and large capacity relay contact switch output module
L5Two channel large volume and large capacity normally open contact relay output module
L51One normally open and one normally closed large volume and large capacity relay contact switch output module
L52Two channel large volume and large capacity normally closed contact relay output module
W1"Burnt out" type thyristor non-contact normally open switch output module
W2"Burnt out" type thyristor non-contact normally closed switch output module
W5'Burnt out' type thyristor non-contact two-way normally open output
*For more functional modules, please consult the manufacturer for specific information
5. Thyristor triggered output module
K1'Burnt out' type single pass zero trigger output module
K3"Burnt out" type three-way thyristor zero crossing trigger output module
K5/K6"Burnt out" type single channel thyristor phase-shift trigger output module
K50/K60"Burnt out" type single channel thyristor phase-shift trigger output module (only applicable to AI-7 series V8.0 and above versions)
K51/K61"Burnt out" type single channel inductive load thyristor phase-shift trigger output module
K9'Burnt out' type direct three-phase three wire thyristor phase-shift trigger output module
6. Input (analog and switch) module
J01-channel three wire heating resistor input or 1-channel thermocouple+1-channel two-wire heating resistor input module
J12-channel thermocouple input module
J22-channel two-wire heating resistor input module
J32-channel voltage input module
J312-channel 0-10V voltage input module
J42-channel current input module
J52-channel transmitter input module (including 24V power supply)
I2Frequency/external PNP switch input interface module
I21Frequency/External NPN Switching Input Interface Module
I31-channel 0-5V/1-5V voltage input interface module
I311-channel 0-10V voltage input interface module
I41-channel 0-20mA/4-20mA current input interface module
I52-channel switch input module
I5A1-channel 0-5A DC current input module
I71-channel 0-5A AC current input module
I81-channel 0-500V AC voltage input module
I201-channel 0-20V DC voltage input module
I501-channel 0-50V DC voltage input module
I1001-channel 0-100V DC voltage input module
I2001-channel 0-200V DC voltage input module
I5001-channel 0-500V DC voltage input module
I10001-channel 0-1000V DC voltage input module
5、 Input Type Table
Thermocouples, thermal resistors, and linear voltage (current) inputs can be freely set. The AI-7 series high-precision instrument also has high-precision Cu50 copper resistance and freezing point compensation functions, and can provide customers with their own input scale and multi-point correction functions, which can adapt to almost all special input requirements.
6、 Optional instrument appearance
Due to the adoption of platform technology, the AI series instruments offer a variety of classic digital instrument panels for selection, as well as D5, D7, E5, E7 DIN rail mounting housings; The dashboard can provide customers with beautiful black and classic light colors for selection.