Product Features
Long lifespan, high sensitivity, low drift, stable and reliable operation
Modular sensors, different types of gas detection probes can be interchanged
Two level concentration alarm with relay output function
LCD display, Chinese interface, combined with two LED indicators for first level alarm and second level alarm
Stainless steel shell, sturdy, waterproof, corrosion-resistant, can adapt to any harsh environment
Double circle joint design, convenient for wiring
4-20mA standard analog output and RS485 digital output, suitable for various control instruments and DCS/PLC systems
Both the controller and remote control can be used for parameter setting
Two switch passive contact outputs
Adopting explosion-proof design suitable for hazardous conditions Zone 1 and Zone 2
performance metrics
Gas detection:Combustible gas, toxic gas
Sampling method: natural diffusion
Detection principle: catalytic combustion/electrochemical/infrared sensor
Concentration units:% LEL, ppm,% VOL
Response time:<30s
Load resistance: ≤ 500 Ω
Detection accuracy: ± 5% F.S
Repeatability: ± 3% F.S
Environmental conditions: Combustible gas temperature: -40 ℃~70 ℃
Toxic gas temperature: -20 ℃~50 ℃
Professional level: ExdIICT6
Protection level: IP65
Power supply: DC24V ± 25%
Output signal: Analog quantity: 4~20mA
2 passive contacts 0.5A/AC220V
Digital quantity: RS-485
Power consumption: ≤ 3W
Cable usage: ≥ RVVP 3 × 1.5mm2Or ≥ RVVP 4 × 1.5mm2
Maximum distance between detector and host: ≤ 1000m
Pressure limit: 86kPa~106kPa
Electrical interface (thread): G1/2, G3/4, etc
Shell color: Stainless steel metal color
Weight: 3400g
Shell material: stainless steel