Beijing Stawo Technology Co., Ltd
Home>Products>PACON4800 UK JEP PACON4800 Water Quality Hardness/Alkalinity Tester
PACON4800 UK JEP PACON4800 Water Quality Hardness/Alkalinity Tester
The UK Jepp PACON 4800 water hardness/alkalinity tester adopts the principle of titration colorimetry and is the most entry-level choice for water sof
Product details

UK Jepp PACON 4800 water hardness/alkalinity testerintroduce

Jepp, UKPACON 4800 water hardness/alkalinity testerThe principle of titration colorimetry is the most entry-level choice for water softening systems and reverse osmosis protection.


Application:

Softened water, reverse osmosis, boiler water, laundry room, groundwater, cooling tower, pharmaceutical water, process water, beverages/food

Beijing PACON 4800 Water Quality Hardness Tester Product Features:

Multiple measurement modes

-Continuous measurement

-Interval measurement (5-99min)

-External switch signal initiates measurement

Fully automatic measurement

Automatically measure the total hardness of water in different ranges based on the selected reagent. This analysis process is more effective than manual measurement and more consistently reliable than other indirect measurement methods such as ion selective electrodes.

Intelligent and accurate

The national standard measurement method - titration colorimetric method, the instrument has calibration function. The integrated measurement technology and two-stage analysis process can identify external measurement influences (such as contamination of the measurement tank, turbidity of the water sample, and external light) and eliminate these influences during the measurement.

Compact design

The size is only 300x300x200mm, which can be directly hung on the wall or installed on a bracket.

Minimal maintenance workload

The water and detection device are completely isolated, with a detachable measuring slot that does not require additional tools for maintenance and can be easily executed. It is recommended to replace the spare parts package once a year (including: peristaltic pump head reagent connecting tube, agitator, sealing ring, order number: 50-5000-10)

Automatic cleaning

Rinsing and Cleaning are automatically performed for each analysis, ensuring measurement accuracy, repeatability, and reducing on-site maintenance.

Low reagent consumption

The reagent bottle can be easily replaced, and 500ml of reagent can measure 5000-10000 times. The validity period of the reagent is 2 years.

LCD backlit LCD display

Multi language graphic backlit LCD displays measurement values, remaining reagent levels, alarm values, and relay status.

0/4-20mA output

SD card data storage

2G data storage card, can be directly imported into the computer to view historical data and system fault information in Excel format

PACON 4800 economical water quality hardness testerBasic parameters:

Measurement principle: titration colorimetric method

Environmental temperature: 5-45 ℃

Water sample temperature: 5-40 ℃

Water sample pressure: 0.5-5 bar, recommended 1-2 bar. If it exceeds 2 bar, it is recommended to install a pressure reducing valve

Water quality requirements: colorless, no suspended solids, no bubbles, pH 4-10.5, iron:< 3ppm, copper:< 0.2ppm aluminum:< 0.1ppm, manganese:< 0.2ppm

Inlet/outlet connection: 6mm outer diameter hose

Humidity: 20-90% RH, indoor installation

Power supply: 85-265VAC, 47-63Hz, 25VA (during operation)

Size/Weight: 300 x 300 x 200mm, ca. 4Kg (including outer box shell)

Protection level: IP65

PACON 4800Technical Parameter

Measurement range: 0.53-534.0 ppm CaCO3 (see reagent type)

Measurement time: about 3 minutes, depending on the hardness of the water and the set flushing time

Accuracy: ± 5% of the upper limit of the selected reagent

Repeatability: ± 5% of the upper limit of the selected reagent

Analysis cycle: continuous measurement/interval measurement (5-99min)/external start signal

Rinse time: 15-1800 seconds

Water consumption: approximately 1000ml/analysis

Display: Backlit LCD displays graphics and numerical values

Optional units: mmol/L, ppm CaCO3, ° dH ° F, etc

Current output: 0/4-20mA, Max. 750-

Relay output: 2-channel passive relay output NC/NO, 250VAC 4A

Input: Analysis of external switch signal activation