ZYR1000yIndicator: 1. Input channel: • 1-8 o'clock The type of measurement signal for each channel can be set by the user themselves 2. Channel isolation: Input channels are isolated from each other without interference. 3. Display function: • Fixed point or cyclic display of measured values Set parameter display [in set state] • Alarm prompt and indicator light Time display [when all input signals are turned off] 4. Recording function: • Adopting imported fixed thermal head, no ink consumption, no pen position Error, anti vibration There are 800 hot stamping points within a range of 100mm • Trend and numerical recording of measured values Print the ruler scale and each channel mark while recording the curve Print the scale value, current time, and paper feed speed every 100mm 5. Real time: • Set the current date and time through the keyboard Even if there is a power outage, it does not affect normal timing 6. Curve migration function: By setting the recording boundary, the trend of different channels can be recorded as curves Separate. 7. Scale conversion function: For voltage and current input signals, the display range can be set, Implement linear scaling for displaying and recording input signals. For thermocouples and The display range of the thermistor signal is its measurement range. 8. Input signal types and measurement ranges: various thermocouples, thermistors, standard voltage and current signals Number, selected by keyboard settings. 9. Paper speed: The paper speed can be set freely through the keyboard, ranging from 10 mm/h to 1990 mm/h. 10. Alarm function: Provide six sets of relay contact outputs, which can be combined and used by users at will Each channel alarm can select upper limit, lower limit, difference upper limit, and difference lower limit The alarm hysteresis of each channel can be set, and there is an indicator light to prompt when the relay is activated Relay contact capacity: 24VDC, 3A; 220VAC, 3A 11. Communication: RS232C or RS485 communication interface 12. Analog output: Two channels of 4-20 mA analog transmission output 13. Sampling period: 0.6S 14. Digital display and alarm accuracy: 0.2%FS? 15. Trend recording accuracy: 0.2%? Two pieces 16. Digital recording accuracy: 0.2%FS? 17. Input impedance: greater than 10M ohms [Note: When measuring current, the input impedance is 250 ohms] 18. Power consumption: not exceeding 30W 19. Normal working environment: Temperature range: 0-50 degrees, humidity range: 10-85% RH 20. Power supply voltage: 220 V; 50 Hz 21. External dimensions: 144 × 144 × 200 mm 22. Hole size: 138 × 138 mm
|