Product Usage:
The product complies with UV testing standards such as IEC 61215-2005, IEC 61345-1998, and GB/T 19394-2003 for photovoltaic modules, used to evaluate the UV radiation resistance of materials such as polymers and protective layers. Before conducting this experiment, light aging or other pretreatment shall be carried out in accordance with the requirements of IEC 61215 or IEC 61646.

1、 Technical parameters:
1. Model: ZN-UV
2. Internal dimensions (D * W * H) mm 800 × 1160 × 500
3. Temperature range: RT+10 ℃~80 ℃;
4. Humidity range: 90-98% R • H;
5. Temperature fluctuation: ± 0.5 ℃;
6. Temperature control method: PID self-tuning temperature control method;
7. Center distance of lamp tube: 70mm;
8. UV wavelengths: UVA-340 and UVB-313
9. The minimum radiation dose accepted by the component is:
Wavelength range 280n m-320n m: 7.5kWh • m-2
Wavelength range 320n m-400n m: 15kWh • m-2
10. Two radiation meter sensors with different wavelength ranges are installed on the transmission shaft, positioned on the centerline of each two lamps.
11. Full process scanning and automatic irradiance compensation ensure uniformity and accuracy. Divide into two groups to ensure the ratio of irradiation in the 280-320nm and 320-400 (or 385) nm bands, while ensuring that the centerline of the component testing surface is uniformly illuminated on both sides.
12. The attenuation of irradiance over time does not cause distortion of the total irradiance and relatively prolongs the service life of the lamp.
13. Lamp power: 40W
14. Lamp installation method: UVA-340 and UVB-313 staggered installation
15. The adjustable range of simulated UV exposure time is 1 to 999H M、S
16. Power supply: AC 380 (± 10%) V/50HZ three-phase five wire system

Photovoltaic module UV aging box/exclusively for Beijing Zhongke environmental testing manufacturer

2、 Box structure:
1. The interior walls of the laboratory are made of SUS304 stainless steel material, which is not decomposed by ultraviolet light, corrosion-resistant, and aesthetically pleasing. The exterior is treated with A3 steel plate spray coating (color can be chosen by the customer), and a channel steel angle iron frame is used between the inner wall and the outer body. The overall structure is sturdy and durable, and the exterior of the laboratory is aesthetically pleasing.
2. According to the standard regulations, a row of light tubes is designed indoors to meet the needs of simultaneous testing of two sets of sample solar panels. The center spacing of the light tubes is 70mm. As the sample is arranged in the largest size, the distance between the center of the light tubes and the sample is 50mm, which can be adjusted
3. Refer to the provisions of the standard. UVA and UVB ultraviolet lamps are divided into two groups, UVA and UVB ultraviolet lamps are installed alternately and controlled in groups, while meeting the required irradiation dose of 7.5 kWh • m-2320nm -400nm. The cumulative irradiation dose reaches the set value, and the equipment automatically shuts down.
4. Indoor design of a solar panel stand that can accommodate the installation of solar panels of different sizes. The height can be adjusted according to the sample or customer's requirements, and the distance from the lamp tube can be adjusted to meet different sample and irradiance requirements. The surface of the solar panel is installed vertically towards the side of the lamp tube, at an angle of approximately 15 degrees to the vertical, allowing water vapor and rainwater to flow smoothly without staying on the surface of the sample.

3、 Temperature and humidity control
UV cycle
The first-order photochemical reaction is not sensitive to temperature changes. However, the speed of the subsequent secondary reaction is closely related to temperature changes. Generally speaking, as the temperature increases, the reaction rate will accelerate. Therefore, temperature control is crucial during UV exposure testing, and it is even more important to match the test temperature used for accelerated testing with the highest temperature encountered by the material in practical applications. The temperature setting of UV in the device can be any point from 50 ℃ to 90 ℃, depending on the level of illumination and indoor ambient temperature. The temperature regulation of the equipment is controlled by a controller with microcomputer calculation function to command a series of systems inside the equipment, such as air heaters, water heaters, etc.

4、 Moisture cycle
As the temperature increases, the destructive power of moisture on materials will sharply increase. Therefore, temperature control is the most basic requirement during wet exposure. Furthermore, to achieve an acceleration effect, it is necessary to maintain a high temperature environment during the wet exposure process. The temperature setting for the condensation process in the device can be any point from 40 ℃ to 80 ℃.

5、 Heating system
1. Adopting U-shaped titanium alloy high-speed heating electric heating tube;
2. Temperature control and lighting are completely independent systems;
3. The temperature control output power is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency;
4. Equipped with anti overheating function of heating system;
The temperature of the black aluminum plate is controlled by an intelligent temperature controller for heating, and the output power is calculated by a microcomputer with PID self-tuning. The monitoring adopts standard Pt-100 blackboard temperature sensor;
During the cyclic testing process, there is a testing section called the dark condensation process, which requires the box to generate saturated water vapor at a relatively high temperature. When the water vapor encounters a relatively cold surface of the sample, it will condense on the surface of the sample.

6、 Control system
1. Intelligent imported touch screen temperature and humidity controller, true color 5.7-inch, LCD touch screen programmable control instrument, easy program editing, simple and convenient operation, combined with French Schneider and other electrical components to form an electrical control system;
2. Accuracy: 0.1 ℃ (display range);
3. Resolution: ± 0.1 ℃;
4. Temperature sensor: PT100 platinum resistance thermometer;
5. Control mode: thermal balance temperature and humidity control mode;
6. Temperature and humidity control adopts P I. D+S.S.R system coordinated control on the same channel;
7. It has the function of automatic calculation, which can immediately correct the temperature and humidity change conditions, making temperature and humidity control more accurate and stable;
8. The controller operation interface is available in both Chinese and English, and the real-time operation curve chart can be displayed on the screen;
9. It has an RS-232 or RS-485 communication interface and can be programmed on a computer to monitor the testing process and perform functions such as automatic power on/off, curve printing, and data processing;
10. Lighting and condensation can be independently controlled or alternately controlled in a cyclic manner;
11. The independent control time and alternating cycle control time for lighting and condensation, as well as the rain exposure time, can be set arbitrarily within 9999 hours, minutes, and seconds;
12. The lamp tube is divided into two groups and controlled separately to meet the required total irradiation amount;
13. Two ultraviolet radiation measurement and control instruments are used to monitor and control the ultraviolet lamps (UVA-340 \ \ UVB-313);
14. In operation or setting, if an error occurs, a warning signal will be provided;
15. Schneider Electric components from France;

7、 Protection system
1. Non fuse protection switch;
2. Overtemperature;
3. Low water level; Overload;
4. Leakage; Door opening protection;
5. Fully sheathed terminal block;
6. Protection such as automatic shutdown;