product overview
The Picarro G2205 gas concentration analyzer can accurately measure hydrogen fluoride (HF) and water vapor (H2O) in real-time, with a sensitivity of parts per trillion (ppt), and the drift generated for atmospheric science and air quality applications can be ignored. This analyzer is equipped with coating components in key gas pathways, which reduces the tendency of HF molecules to adhere to the surface of the gas pathway, thereby improving the measurement response time. This analyzer requires almost no consumables, therefore it has significant advantages of ease of use and lower purchase cost. This analyzer has a sturdy structure and is easy to transport.
Product Features
• Fast, continuous, and real-time measurement of HF
• Long term stability to meet low-frequency calibration requirements
• Small footprint, suitable for on-site or laboratory deployment, no need for consumables
• Equipped with water correction function, automatically reporting dry gas mole fraction
Main technical parameters
Picarro G2205Performance specifications |
|
|
Target gas (In air like matrix) |
limit of detection*(5 minute,3σ) |
zero drift*(24 Within hours/ 1Within a month (5 Peak of minute mean-Peak value) |
HF |
30 ppt |
± 0.15 / ± 0.5 ppb |
Picarro G2205System specifications |
|
measurement |
cavity ring-down spectroscopy( CRDS )technology |
Measurement pool temperature control |
±0.005 ℃ |
Measurement pool pressure control |
±0.0002atmospheric pressure |
measuring range |
Ensure that the specification range is0–0.5 ppmThe scope of work is0–1.0 ppmThe accuracy of measuring higher concentrations is approximately30 ppt + 0.5%reading |
Measurement Interval |
make an appointment 5 second |
response time |
90–10%Descent time,0.3 ppm - 0,< 10minute.10–90%Rise time,0–0.3 ppm,< 10minute |
sample temperature |
-10 to45 ℃ |
Sample flow rate |
exist 760 Underneath less than 0.6 Standard liters per minute( slm )No need for filtering |
Sample pressure |
300 to 1000 Tuo(40 to 133 Kilopascals) |
Sample humidity |
relative humidity( RH )less than99%(In)40 ℃Under non condensing conditions.H2OIt will affectHFMeasurement. To achieve optimal performance, Both can beHFDrying treatment can also provide consistencyH2Oconcentration |
ambient temperature |
10 to35 ℃(Running);-10 to50 ℃(Storage) |
ambient humidity |
relative humidity( RH )less than99%Under non condensing conditions |
Other gases measured |
H2O、O2 |
attachment |
Pump (external, included), keyboard (included), mouse (included)LCDMonitor (including) |
data output |
RS-232EthernetUSBSimulation (optional)0–10bend over |
Air inlet connector |
¼inchSwagelok ® PFAjoint |
External dimensions |
Analyzer:17 Inches widex 7Inch heightx 17.5Inch length(43.2 x 17.9 x 44.6Centimeters), excluding 0.5 Inch foot external pump:12.8 Inch lengthx 8.9Inch heightx 6.2Inches wide(32.4 x 22.6 x 15.8Centimeters) |
Installation form |
Workbench or 19 Inch rack mounted chassis |
weight |
70 Pound(31.75 Kilogram, including pump |
Power requirements |
100–240Alternating current,47–63 Hz(Automatic detection), when started (total) less than 260 Wa:110 Watt (analyzer), steady state is 120 Watt (pump) |
calibration |
The calibration of this instrument is limited by the preparation of constant concentration samples. We should investigate whether the instrument is suitable for commercial standards based on your application. For more details, please contactPicarro. |