Picarro G2508 gas concentration analyzer
Picarro G2508 gas concentration analyzer
Product details

Product Overview

The Picarro G2508 gas concentration analyzer can simultaneously measure nitrous oxide (N2O), methane (CH4), carbon dioxide (CO2), ammonia (NH3), and water vapor (H2O), with a sensitivity of parts per billion (ppb). The drift generated by agricultural and soil science, ecology, and quantitative emission applications can be ignored. This analyzer can operate in open or closed systems and can be easily integrated with chamber systems.

Product Features

Synchronous continuous measurement of N2O, CH4, CO2, NH3, and H2O

Billion parts per billion (ppb) sensitivity, capable of achieving excellent rate of increase quantification

Fast response time and continuous measurement function ensure data is provided with high temporal resolution

Can operate in open or closed systems and easily integrate with chamber systems

Equipped with water correction function, automatically reporting dry gas mole fraction

Main technical parameters

Picarro G2508Performance specifications in air

Specifications

N2O

CH4

CO2

NH3

H2O

Initial accuracy( 1σ )

< 25 ppb

< 10 ppb

< 600 ppb

< 5 ppb

< 500 ppm

Accuracy,1 minute( 1σ )

< 10 ppb

< 7 ppb

< 300 ppb

< 3 ppb

< 250 ppm

Accuracy,5 minute( 1σ )

< 5 ppb +0.008%reading

< 5 ppb +0.02%reading

< 200 ppb +0.05%reading

< 1 ppb +0.05%reading

< 100 ppm

Ensure accuracy range

0.3–200 ppm

1.5–12 ppm

380–5000 ppm

0–300 ppb

0–3 %

measuring range

0–400 ppm

0.5–15 ppm

0.02–2 %

0–2 ppm

0–7 %

Measurement rate

< 8second

< 8second

< 8second

< 8second

< 8second

Typical gas response

~ 8second

~ 8second

~ 8second

See the annotation below

See the annotation below

Report dry mole fraction

yes

yes

yes

no

Not applicable

Annotation:H2OandNH3 The response is limited by its adsorption on the surface of the experimental device. Although the analyzer will accurately measure the inside of the optical cavityNH3 andH2OCalculate the concentration of, but use these measured values to calculate the soilNH3 andH2OThe actual flux will become complex due to the adsorption dynamics within the system.

Specificity of the analyzer: Compared with other spectroscopic measurement techniques, Picarro CRDS technology utilizes an extremely narrow spectral region, which can significantly reduce the possibility of interference from other gas species. However, interference may still occur in actual samples. Not only is the Picarro analyzer equipped with interference detection software, but the effects of the following gases on the analyzer have also been tested and characterized:

Picarro G2508Trace interference gas

N2OSensitivity

carbon dioxide

nothing-Automatically calibratable20000 ppm CO2

methane

nothing-Automatically calibratable200 ppm CH4

ammonia

nothing-Automatic calibration is good, achieving2 ppm NH3

ethane

0.2 ppb N2O / ppm C2H6The highest value tested is120 ppm

ethylene

0.5 ppb N2O / ppm C2H4The highest value tested is16 ppm

acetylene

Not applicable for acetylene experiment

Background gas

Designed for use in ambient air, not suitable for background gases with drastic changes in composition or high-purity gasesN2O2H2HeWaiting for background gas

ChemDetect ™Software

distinctivePicarroAlgorithm detects and marks data that may be inaccurate due to spectral interference

Picarro G2508System operating parameters

Specifications

ambient temperature

10–35 ℃

ambient humidity

< 99%Relative humidity, under non condensing conditions

Sample pressure

300 to 1000 Tuo(40 to 133 Kilopascals)

Sample flow rate

~ 230Standard milliliters per minute

Sample humidity

< 99%Relative humidity, non condensing conditions, water vapor calibration test until25 ℃the dew point

Sample temperature

-10–45 ℃

Optical cavity temperature control

±0.005 ℃

Optical cavity pressure control

±0.0002Atmospheric pressure

closed circuit/Recycling capability

WithPicarroClosed circuit system pumpA0702compatible

Air inlet accessories

¼inchSwagelok ®

External dimensions

17Inches widex 7Inch heightx 17.5Inch deep(43.2 x 17.8 x 44.6Centimeters), excluding 0.5Inch legs

weight

50 Pound(22.6 Kilogram)

Power requirements

100–240Alternating current,47–63Hertz (automatic detection).< 260Total power of watt startup, in steady state 110 tile

Installation form

Desktop (standard) or19”Rack mounted chassis (optional)

enclosure

Including: keyboard, mouse. Optional accessories: LCD display. Excluding: vacuum pump.

option

A0702PicarroClosed circuit system pump

S0528O2 Sensors, used for different purposesO2 In the environmentO2 Measurement and calibrationS0517: ExpansionCH4 Operating range, up to800 ppm