Fixed ultrasonic flowmeter
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
High precision measurement
The line quality is better than 0.5%, the repeatability accuracy is better than 0.2%, and the measurement accuracy is better than ± 1.0%;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
■ Supports Chinese and English menus
Different versions of flow meters can support Chinese or English menus for convenience and speed;
■ Strong reliability
The use of low voltage and multi pulse transmission circuits significantly improves measurement accuracy, service life, and reliability;
Strong anti-interference ability
Adopting dual balanced signal differential transmission and receiving circuit, effectively resisting strong interference sources such as frequency converters, TV towers, and high-voltage lines;
■ Powerful memory function
Automatically remember the accumulated traffic of the first 64 days, the first 64 months, and the first 5 years, automatically remember the time and traffic of the first 64 incoming and power outages, automatically remember the previous
Is the working status of the 64 day flowmeter normal.
Optional sensor
Basic model
measuring range
Fluid temperature
accuracy
power supply
input
output
communication protocol
External clip type
TS-1
(Small)TUF-2000BNB1
DN15-100mm
-30-90 ℃
± 1%
One time table
DC8-36V
Secondary table
AC220V
Or DC24V3-channel 4-20mA
analog input
2-way 3-wire system
PT100 resistance signal
inputIsolate RS232/
RS485
input
2-channel isolated OCT
output
1-way isolation 4-20mA
output
(Passive)METER-BUS
agreement
MODBUS
agreement
Fuji
extend
agreement
simple and easy
water meter
agreementTM-1
(Medium size)TUF-2000BNB2
DN50-700mm
TL-1
(Large)TUF-2000BNB3
DN300-6000mm
High temperature external clamp type
TH2-1
(Small)TUF-2000BNB4
DN15-100mm
-30-160 ℃
THM-1
(Medium size)TUF-2000BNB5
DN50-700mm
plug-in
TC-1
(Standard Insertion)TUF-2000BNC1
DN80-6000mm
-40-160 ℃
TLC-2
(Extended insertion)TUF-2000BNC2
Pipe section type
Standard pipe section type
TUF-2000BNG
DN15-1000mm
-40-160 ℃
Selectable hosts
Wall mounted TUF-2000FB
·Used for wall mounted installation
·Size: 178 × 165 × 55mmDisk mounted TUF-2000FS
·Used for dashboard installation
·Hole size: 152mm × 76mmExplosion proof TUF-2000FD
·Explosion proof grade D Ⅱ BT4, used in explosion-proof situations
·Size: 285 × 265 × 90nn
Fixed ultrasonic flowmeter
1、 Overview
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
■ Accuracy measurement
The line quality is better than 0.5%, the repeatability accuracy is better than 0.2%, and the measurement accuracy is better than ± 1.0%;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
High protection level
The protection level of a single meter can reach IP68, and it can penetrate 2 meters underwater for operation;
■ Easy to operate
Magnetic strips can be used to browse parameters on the primary table, and parameters can also be reset or displayed in Chinese through the secondary table;
■ Multiple display
The primary meter and signal detection are integrated with flow measurement, which can display cumulative flow rate, flow velocity in a loop. The secondary meter can display more than 100 menus in Chinese
Long transmission distance and fast networking
RS-485 bus communication is used between the primary and secondary meters, and ordinary cables are sufficient. The transmission distance can reach over 1000 meters, and the networking speed is convenient and fast This transmission method has strong anti-interference ability Solved the problems of high cost, poor anti-interference ability, and short transmission distance of dedicated cables for split type ultrasonic flow meters.
Optional secondary meter (for single point measurement, remote display, and parameter setting)
RS485 bus communication
(Transmission distance can reach over 1000m)
24V power supply.
Networking measurement diagram RS485 bus communication (transmission example can reach over 1000m)
Wall mounted TUF-2000FB
·Used for wall mounted installation
·Size: 178 × 165 × 55mm
Disk mounted TUF-2000FS
·Used for dashboard installation
·Hole size: 152mm × 76mm
Explosion proof TUF-2000FD
·Explosion proof grade D Ⅱ BT4, used in explosion-proof situations
·Size: 285 × 265 × 90nn
Portable ultrasonic flowmeter
1、 Overview
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
High precision measurement
The line quality is better than 0.5%, the repeatability accuracy is better than 0.2%, and the measurement accuracy is better than ± 1.0%;
■ Non contact measurement
Attach the magnetic ultrasonic flowmeter sensor to the outer wall of the pipeline to complete flow measurement;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
■ Supports Chinese and English menus
Different versions of flow meters can support Chinese or English menus for convenience and speed;
■ Charging power supply
Equipped with a large capacity nickel hydrogen rechargeable battery, it can support continuous operation of the flowmeter for more than 20 hours;
■ Built in printer
Real time screen printing can be achieved, and up to 20 pre-set measurement results can be printed on a scheduled basis;
■ Built in data logger
Up to 20 pre-set measurement results can be uploaded to a computer or networked communication.
standard model
model
quantity
describe
host
TUF-2000P
1 piece
Volume: 225 × 180 × 67mm, working temperature: -20-60 ℃, measurement accuracy ± 1%
Medium sized sensor
TM-1
2 pieces
Magnetic, volume: 64 × 35 × 32mm, working temperature: -40-110 ℃, measurement range DN50-DN700mm
Ultrasonic specialized signal cable
2 pieces
Length: 5m, used to connect the ultrasonic flowmeter host and sensor
power line
1 piece
Length of 3M, used for charging ultrasonic flow meters or using AC power for long-term adjustment
Thermal printing paper
2 rolls
Length: 30m
Ultrasonic special coupling agent
1 bottle
Weight: 110g, used for ultrasonic signal propagation between ultrasonic sensors and pipe walls
Ratchet Buckle
2 pieces
Length: 3m, high tensile strength: 100kg, used for binding non-magnetic pipeline sensors
tape measure
1 piece
Length: 3m, used for measuring the circumference of pipelines or the installation distance between two probes
instructions
1 book
Aluminum alloy protective box
1 piece
Volume: 456 × 335 × 133mm suitable for harsh environments such as outdoor and underground
Optional sensors
model
describe
measuring range
Small sensors
TS-1
With magnetism
DN15-DN100MM
Medium sized sensor
TM-1
With magnetism
DN50-DN700MM
Large sensors
TL-1
With magnetism
DN300-DN6000MM
High temperature small sensor
HTS-1
DN15-DN100MM
High temperature medium-sized sensor
HTM-1
DN50-DN1000MM
Other optional hardware
model
describe
measuring range
ultrasonic thickness gauge
TT100
Accurately measuring pipeline wall thickness to improve flow monitoring accuracy
1.2-225.0mm
Extended signal cable
Length 10m × 2
Suitable for measuring situations where the pipeline is far away from the host
Extended tensioner
Length 6m x 2
Suitable for fixing sensors with pipeline diameters exceeding 1000mm
Thermal printing paper
Length 30m
Linearity
0.5%
repeatability
0.2%
accuracy
± 1% of the indicated value, flow rate>0.2m/s
response time
0-999 seconds, user can choose
flow rate range
± 32m/s
measuring aperture
15-6000mm
Measurement unit
Meter, foot, cubic meter, liter, cubic foot, US gallon, UK gallon, oil drum
US liquid barrel, UK liquid barrel, US megagallon, user set unitAccumulator
7-digit, negative, net accumulator
Liquid type
Various single and uniform liquids capable of conducting sound waves
safety
Lock the setting value, unlock when changing data
display
4 × 8 in Chinese or 4 × 16 in English
Communication interface
RS-232, baud rate 75-57600, compatible with Fuji ultrasonic flowmeter, and also compatible with other devices according to user requirements
Productsensor
Standard M1 type, with 4 other options available
sensor cable
The standard is 5m × 2, and it can also be extended to 10m × 2
power supply
3 AAA built-in Ni-H batteries, capable of working continuously for 12 hours on each full charge, AC100-240V adapter
data record
Built in data logger, capable of recording 2000 rows of data
Manual accumulator
7-digit, press the button to start calibration
Housing material
Flame retardant ABS
Shell size
200 × 90 × 30mm
Weight
500g (1.2Ibs) including battery
Coding rules for portable ultrasonic flow meters
TUF-2000H
Standard TS-1 type
2 standard TM-1 type
3 standard TL-1 type
give an example: TUF-2000H1
Explanation: Handheld ultrasonic flowmeter, standard configuration
Optional standard small sensor TS-1 type
Handheld ultrasonic flowmeter
1、 Overview
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
■ Accuracy measurement
Accuracy can reach ± 1.0%, linearity 0.5%, repeatability accuracy 0.2%
■ Small size and light weight
The volume is only 210 × 90 × 30mm, and the weight is only 0.5KG;
■ Non contact measurement
Attach the magnetic ultrasonic flowmeter sensor to the outer wall of the pipeline to complete flow measurement;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
■ Charging power supply
Equipped with a large capacity nickel hydrogen rechargeable battery, it can support continuous operation of the flowmeter for more than 20 hours;
■ Print screen LCD display
It can simultaneously display cumulative flow, instantaneous flow, flow rate, working status, etc;
■ Built in data logger
The built-in data logger has a space of 24 bytes and can store 2000 rows of measurement data;
standard model
model
quantity
describe
host
TUF-2000P
1 piece
Volume: 210 × 90 × 30mm, working temperature: -20-60 ℃, measurement accuracy ± 1%
Medium sized sensor
TM-1
2 pieces
Magnetic, volume: 64 × 35 × 32mm, working temperature: -40-110 ℃, measurement range DN50-DN700mm
Ultrasonic specialized signal cable
2 pieces
Length: 5m, used to connect the ultrasonic flowmeter host and sensor
data line
1 piece
Length of 1m, used to export measurement data stored in the data logger to a computer
The power adapter
1 piece
Length of 1m, used for charging handheld ultrasonic flow meters
Ultrasonic special coupling agent
1 bottle
Weight: 110g, used for ultrasonic signals between ultrasonic sensors and pipe walls
SpreadRatchet Buckle
2 pieces
Length: 3m, high tensile strength: 100kg, used for binding non-magnetic pipeline sensors
tape measure
1 piece
Length: 3m, used for measuring the circumference of pipelines or the installation distance between two probes
instructions
1 book
Aluminum alloy protective box
1 piece
Volume: 415 × 315 × 100mm
Optional sensors
model
describe
measuring range
temperature range
Small sensors
TS-1
With magnetism
DN15-DN100MM
-40-110 ℃
Medium sized sensor
TM-1
With magnetism
DN50-DN700MM
-40-110 ℃
Large sensors
TL-1
With magnetism
DN300-DN6000MM
-40-110 ℃
High temperature small sensor
HTS-1
DN15-DN100MM
-40-160 ℃
High temperature medium-sized sensor
HTM-1
DN50-DN1000MM
-40-160 ℃
Other optional hardware
model
describe
measuring range
temperature range
ultrasonic thickness gauge
TT100
Accurately measuring pipeline wall thickness to improve flow monitoring accuracy
1.2-225.0mm
± 1% H ± 0.1mH is the thickness of the measured substance
Extended signal cable
Length 10m × 2
Suitable for measuring situations where the pipeline is far away from the host
Extended tensioner
Length 6m x 2
Suitable for fixing sensors with pipeline diameters exceeding 1000mm
Attributes [Origin] Jiangsu [nominal diameter] 100 [Customized Processing] correct [Brand] DETAIR [Model] TUF-2000-25 [Work pressure] 25 [Working temperature] 120 [Is it a cross-border export exclusive source of goods] deny [Whether to import] deny [Measurement Range] 55 [Type] ultrasonic flowmeter [Accuracy level] 4 [Order Number] 20180705 [Item Number] 20180705 [Applicable medium] liquid [DN100] 2700.00 yuan [DN150] 3200.00 yuan [DN50] 2400.00 yuan