Nanjing Ditaier Instrument Electromechanical Equipment Co., Ltd
Home>Products>Pipe section ultrasonic flowmeter, flange connection, on-site display of DN15-DN350 caliber, made of carbon steel material
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13805157582
  • Address
    No. 188 Daguang Road, Jinjiang Lishe
Contact Now
Pipe section ultrasonic flowmeter, flange connection, on-site display of DN15-DN350 caliber, made of carbon steel material
The fixed ultrasonic flowmeter TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual
Product details

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

Fixed ultrasonic flowmeter

The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
High precision measurement
The line quality is better than 0.5%, the repeatability accuracy is better than 0.2%, and the measurement accuracy is better than ± 1.0%;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
■ Supports Chinese and English menus
Different versions of flow meters can support Chinese or English menus for convenience and speed;
■ Strong reliability
The use of low voltage and multi pulse transmission circuits significantly improves measurement accuracy, service life, and reliability;
Strong anti-interference ability
Adopting dual balanced signal differential transmission and receiving circuit, effectively resisting strong interference sources such as frequency converters, TV towers, and high-voltage lines;
■ Powerful memory function
Automatically remember the accumulated traffic of the first 64 days, the first 64 months, and the first 5 years, automatically remember the time and traffic of the first 64 incoming and power outages, automatically remember the previous
Is the working status of the 64 day flowmeter normal.

Optional sensor

Basic model

measuring range

Fluid temperature

accuracy

power supply

input

output

communication protocol

External clip type

TS-1
(Small)

TUF-2000BNB1

DN15-100mm

-30-90 ℃

± 1%

One time table
DC8-36V

Secondary table
AC220V
Or DC24V

3-channel 4-20mA
analog input

2-way 3-wire system
PT100 resistance signal
input

Isolate RS232/
RS485
input

2-channel isolated OCT
output

1-way isolation 4-20mA
output
(Passive)

METER-BUS
agreement

MODBUS
agreement

Fuji
extend
agreement

simple and easy
water meter
agreement

TM-1
(Medium size)

TUF-2000BNB2

DN50-700mm

TL-1
(Large)

TUF-2000BNB3

DN300-6000mm

High temperature external clamp type

TH2-1
(Small)

TUF-2000BNB4

DN15-100mm

-30-160 ℃

THM-1
(Medium size)

TUF-2000BNB5

DN50-700mm

plug-in

TC-1
(Standard Insertion)

TUF-2000BNC1

DN80-6000mm

-40-160 ℃

TLC-2
(Extended insertion)

TUF-2000BNC2

Pipe section type

Standard pipe section type

TUF-2000BNG

DN15-1000mm

-40-160 ℃

Selectable hosts

超声波流量计

超声波流量计

超声波流量计

Wall mounted TUF-2000FB
·Used for wall mounted installation
·Size: 178 × 165 × 55mm

Disk mounted TUF-2000FS
·Used for dashboard installation
·Hole size: 152mm × 76mm

Explosion proof TUF-2000FD
·Explosion proof grade D Ⅱ BT4, used in explosion-proof situations
·Size: 285 × 265 × 90nn

超声波流量计

Fixed ultrasonic flowmeter

1、 Overview
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
■ Accuracy measurement
The line quality is better than 0.5%, the repeatability accuracy is better than 0.2%, and the measurement accuracy is better than ± 1.0%;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
High protection level
The protection level of a single meter can reach IP68, and it can penetrate 2 meters underwater for operation;
■ Easy to operate
Magnetic strips can be used to browse parameters on the primary table, and parameters can also be reset or displayed in Chinese through the secondary table;
■ Multiple display
The primary meter and signal detection are integrated with flow measurement, which can display cumulative flow rate, flow velocity in a loop. The secondary meter can display more than 100 menus in Chinese
Long transmission distance and fast networking
RS-485 bus communication is used between the primary and secondary meters, and ordinary cables are sufficient. The transmission distance can reach over 1000 meters, and the networking speed is convenient and fast This transmission method has strong anti-interference ability Solved the problems of high cost, poor anti-interference ability, and short transmission distance of dedicated cables for split type ultrasonic flow meters.

Optional secondary meter (for single point measurement, remote display, and parameter setting)

超声波流量计

RS485 bus communication
(Transmission distance can reach over 1000m)
24V power supply

.

超声波流量计

Wall mounted TUF-2000FB
·Used for wall mounted installation
·Size: 178 × 165 × 55mm

超声波流量计

Disk mounted TUF-2000FS
·Used for dashboard installation
·Hole size: 152mm × 76mm

超声波流量计

Explosion proof TUF-2000FD
·Explosion proof grade D Ⅱ BT4, used in explosion-proof situations
·Size: 285 × 265 × 90nn

Networking measurement diagram RS485 bus communication (transmission example can reach over 1000m)

超声波流量计

超声波流量计

超声波流量计

超声波流量计

超声波流量计

Portable ultrasonic flowmeter

1、 Overview
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
High precision measurement
The line quality is better than 0.5%, the repeatability accuracy is better than 0.2%, and the measurement accuracy is better than ± 1.0%;
■ Non contact measurement
Attach the magnetic ultrasonic flowmeter sensor to the outer wall of the pipeline to complete flow measurement;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
■ Supports Chinese and English menus
Different versions of flow meters can support Chinese or English menus for convenience and speed;
■ Charging power supply
Equipped with a large capacity nickel hydrogen rechargeable battery, it can support continuous operation of the flowmeter for more than 20 hours;
■ Built in printer
Real time screen printing can be achieved, and up to 20 pre-set measurement results can be printed on a scheduled basis;
■ Built in data logger
Up to 20 pre-set measurement results can be uploaded to a computer or networked communication.

standard model

model

quantity

describe

host

TUF-2000P

1 piece

超声波流量计

Volume: 225 × 180 × 67mm, working temperature: -20-60 ℃, measurement accuracy ± 1%

Medium sized sensor

TM-1

2 pieces

超声波流量计

Magnetic, volume: 64 × 35 × 32mm, working temperature: -40-110 ℃, measurement range DN50-DN700mm

Ultrasonic specialized signal cable

2 pieces

超声波流量计

Length: 5m, used to connect the ultrasonic flowmeter host and sensor

power line

1 piece

超声波流量计

Length of 3M, used for charging ultrasonic flow meters or using AC power for long-term adjustment

Thermal printing paper

2 rolls

超声波流量计

Length: 30m

Ultrasonic special coupling agent

1 bottle

超声波流量计

Weight: 110g, used for ultrasonic signal propagation between ultrasonic sensors and pipe walls

Ratchet Buckle

2 pieces

超声波流量计

Length: 3m, high tensile strength: 100kg, used for binding non-magnetic pipeline sensors

tape measure

1 piece

超声波流量计

Length: 3m, used for measuring the circumference of pipelines or the installation distance between two probes

instructions

1 book

超声波流量计

Aluminum alloy protective box

1 piece

超声波流量计

Volume: 456 × 335 × 133mm suitable for harsh environments such as outdoor and underground

Optional sensors

model

describe

measuring range

Small sensors

TS-1

超声波流量计

With magnetism

DN15-DN100MM

Medium sized sensor

TM-1

超声波流量计

With magnetism

DN50-DN700MM

Large sensors

TL-1

超声波流量计

With magnetism

DN300-DN6000MM

High temperature small sensor

HTS-1

超声波流量计

DN15-DN100MM

High temperature medium-sized sensor

HTM-1

超声波流量计

DN50-DN1000MM

Other optional hardware

model

describe

measuring range

ultrasonic thickness gauge

TT100

超声波流量计

Accurately measuring pipeline wall thickness to improve flow monitoring accuracy

1.2-225.0mm

Extended signal cable

超声波流量计

Length 10m × 2

Suitable for measuring situations where the pipeline is far away from the host

Extended tensioner

超声波流量计

Length 6m x 2

Suitable for fixing sensors with pipeline diameters exceeding 1000mm

Thermal printing paper

超声波流量计

Length 30m

Linearity

0.5%

repeatability

0.2%

accuracy

± 1% of the indicated value, flow rate>0.2m/s

response time

0-999 seconds, user can choose

flow rate range

± 32m/s

measuring aperture

15-6000mm

Measurement unit

Meter, foot, cubic meter, liter, cubic foot, US gallon, UK gallon, oil drum
US liquid barrel, UK liquid barrel, US megagallon, user set unit

Accumulator

7-digit, negative, net accumulator

Liquid type

Various single and uniform liquids capable of conducting sound waves

safety

Lock the setting value, unlock when changing data

display

4 × 8 in Chinese or 4 × 16 in English

Communication interface

RS-232, baud rate 75-57600, compatible with Fuji ultrasonic flowmeter, and also compatible with other devices according to user requirements
Product

sensor

Standard M1 type, with 4 other options available

sensor cable

The standard is 5m × 2, and it can also be extended to 10m × 2

power supply

3 AAA built-in Ni-H batteries, capable of working continuously for 12 hours on each full charge, AC100-240V adapter

data record

Built in data logger, capable of recording 2000 rows of data

Manual accumulator

7-digit, press the button to start calibration

Housing material

Flame retardant ABS

Shell size

200 × 90 × 30mm

Weight

500g (1.2Ibs) including battery

Coding rules for portable ultrasonic flow meters

TUF-2000H

Standard TS-1 type

2 standard TM-1 type

3 standard TL-1 type

give an example: TUF-2000H1

Explanation: Handheld ultrasonic flowmeter, standard configuration

Optional standard small sensor TS-1 type

超声波流量计

Handheld ultrasonic flowmeter

1、 Overview
The TUF series ultrasonic flowmeter utilizes the principle of low voltage and multi pulse time difference, and adopts dual balanced signal differential transmission and differential reception digital detection technology to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive sound waves is the same (the only technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the reverse direction is greater than that in the water flow direction. The relationship conforms to the following expression:
2、 Instrument features
■ Accuracy measurement
Accuracy can reach ± 1.0%, linearity 0.5%, repeatability accuracy 0.2%
■ Small size and light weight
The volume is only 210 × 90 × 30mm, and the weight is only 0.5KG;
■ Non contact measurement
Attach the magnetic ultrasonic flowmeter sensor to the outer wall of the pipeline to complete flow measurement;
■ Large measurement range
By selecting different types of sensors, it is possible to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000mm;
■ Charging power supply
Equipped with a large capacity nickel hydrogen rechargeable battery, it can support continuous operation of the flowmeter for more than 20 hours;
■ Print screen LCD display
It can simultaneously display cumulative flow, instantaneous flow, flow rate, working status, etc;
■ Built in data logger
The built-in data logger has a space of 24 bytes and can store 2000 rows of measurement data;

standard model

model

quantity

describe

host

TUF-2000P

超声波流量计

1 piece

Volume: 210 × 90 × 30mm, working temperature: -20-60 ℃, measurement accuracy ± 1%

Medium sized sensor

TM-1

超声波流量计

2 pieces

Magnetic, volume: 64 × 35 × 32mm, working temperature: -40-110 ℃, measurement range DN50-DN700mm

Ultrasonic specialized signal cable

超声波流量计

2 pieces

Length: 5m, used to connect the ultrasonic flowmeter host and sensor

data line

超声波流量计

1 piece

Length of 1m, used to export measurement data stored in the data logger to a computer

The power adapter

超声波流量计

1 piece

Length of 1m, used for charging handheld ultrasonic flow meters

Ultrasonic special coupling agent

超声波流量计

1 bottle

Weight: 110g, used for ultrasonic signals between ultrasonic sensors and pipe walls
Spread

Ratchet Buckle

超声波流量计

2 pieces

Length: 3m, high tensile strength: 100kg, used for binding non-magnetic pipeline sensors

tape measure

超声波流量计

1 piece

Length: 3m, used for measuring the circumference of pipelines or the installation distance between two probes

instructions

超声波流量计

1 book

Aluminum alloy protective box

超声波流量计

1 piece

Volume: 415 × 315 × 100mm

Optional sensors

model

describe

measuring range

temperature range

Small sensors

TS-1

超声波流量计

With magnetism

DN15-DN100MM

-40-110 ℃

Medium sized sensor

TM-1

超声波流量计

With magnetism

DN50-DN700MM

-40-110 ℃

Large sensors

TL-1

超声波流量计

With magnetism

DN300-DN6000MM

-40-110 ℃

High temperature small sensor

HTS-1

超声波流量计

DN15-DN100MM

-40-160 ℃

High temperature medium-sized sensor

HTM-1

超声波流量计

DN50-DN1000MM

-40-160 ℃

Other optional hardware

model

describe

measuring range

temperature range

ultrasonic thickness gauge

TT100

超声波流量计

Accurately measuring pipeline wall thickness to improve flow monitoring accuracy

1.2-225.0mm

± 1% H ± 0.1mH is the thickness of the measured substance

Extended signal cable

超声波流量计

Length 10m × 2

Suitable for measuring situations where the pipeline is far away from the host

Extended tensioner

超声波流量计

Length 6m x 2

Suitable for fixing sensors with pipeline diameters exceeding 1000mm

Attributes
[Origin] Jiangsu
[nominal diameter] 100
[Customized Processing] correct
[Brand] DETAIR
[Model] TUF-2000-25
[Work pressure] 25
[Working temperature] 120
[Is it a cross-border export exclusive source of goods] deny
[Whether to import] deny
[Measurement Range] 55
[Type] ultrasonic flowmeter
[Accuracy level] 4
[Order Number] 20180705
[Item Number] 20180705
[Applicable medium] liquid
[DN100] 2700.00 yuan
[DN150] 3200.00 yuan
[DN50] 2400.00 yuan
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!