Plating standard sheet - gold (au)
Details
1.productpurpose:
Coating standard sheetMainly used to verify the accuracy of electrolytic thickness gauges, this standard piece has been inspected and certified by the Institute of Protective Materials and designated as the thickness standard inspection piece for electrolytic thickness gauges. Due to its high precision and good uniformity, it has been widely used as a unified standard for thickness in the electroplating industry. Coating standard sheet, also known as film thickness gauge calibration sheet or thin film sheet, is professionally used forThe X-ray thickness gauge (film thickness gauge) is used for instrument standardization calibration and establishing measurement analysis files when measuring the thickness of metal coatings.
2.productcharacteristic:
AmericaCalmetrics coating standard sheet is suitable for Fischer, Korean ISP, Oxford, Oxford, etc, CMI、 Roentgenanalytik, Thermoelectric Veeco、 Micro Pioneer, Seiko, Shimadzu, Denso, Boman BOWMAN, Hemei, Nayou, Tianrui, Huawei and other brands of X-ray thickness gauges Various specifications and sizes based on various principles such as beta ray thickness gauge, magnetic induction, and eddy current
3. Main functions
●Feature: Standard filmA2LA calibration certification, excellent quality, high precision, and good stability
●Thickness gauge standard sheet, also known as film thickness gauge calibration sheet or thin film sheet, is professionally used forThe X-ray thickness gauge (film thickness gauge) is used for instrument standardization calibration and establishing measurement analysis files when measuring the thickness of metal coatings.
X-ray thickness gauge standard plates are generally divided into single coating plates, double coating plates, multi coating plates, alloy coating plates, and chemical coating plates. For example: Single plating: Ag/xx, Double coating: Au/Ni/xx, Triple coating: Au/Pd/Ni/xx, Alloy coating: Sn-Pb/xx, Chemical coating: Ni-P/xx。 (All standard pieces come with NIST certificates) We can customize qualified standard pieces from American factories according to customers' different requirements for metal elements, coating structures, and coating thicknesses, and provide NIST certificates for the thickness values of the standard pieces
4. Working conditions
Avoid placing in places with direct sunlight, high temperature or humidity, and high dust. The working environment requirement is room temperature.
When not in use, place the device in a specific file bag to avoid loss.
5.Technical Parameter(Common specifications):
element |
Content ratio |
thickness |
||
Main element |
Secondary element |
uin |
um |
|
Au |
100 |
0 |
1 |
0.025 |
Au |
100 |
0 |
2 |
0.05 |
Au |
100 |
0 |
4 |
0.10 |
Au |
100 |
0 |
10 |
0.25 |
Au |
100 |
0 |
20 |
0.50 |
Au |
100 |
0 |
30 |
0.75 |
Au |
100 |
0 |
40 |
1.00 |
Au |
100 |
0 |
50 |
1.25 |
Au |
100 |
0 |
60 |
1.50 |
Au |
100 |
0 |
70 |
1.75 |
Au |
100 |
0 |
80 |
2.00 |
Au |
100 |
0 |
100 |
2.50 |
Au |
100 |
0 |
120 |
3.00 |
Au |
100 |
0 |
150 |
3.75 |
Au |
100 |
0 |
200 |
5.00 |
Au |
100 |
0 |
250 |
6.25 |
Au |
100 |
0 |
300 |
7.50 |
[Return]