Widely used for laboratory testing of wastewater treatment and production processes in industrial and mining enterprises, water plants, sewage treatment plants, etc.
Instrument characteristics
The instrument can measure dissolved oxygen concentration, saturation, electrode current, and temperature
Adopting microprocessor technology and wide screen LCD display. It also has an operation prompt function, making it easy and convenient to use. Adopting a new typePCPanel, good reliability
Equipped with automatic temperature compensation function. Can be calibrated for zero oxygen, saturation, air pressure, and salinity. Power outage protection and other functions
It has functions such as power-off protection. The test results can be stored, deleted, viewed, and printed. Maximum storage capacity250Set measurement data and provide two printing modes for users to choose from: instant printing and storage printing
The instrument adopts a low-power design and has power management functions such as undervoltage display and automatic shutdown
haveRS-232Interface, can be connectedTP-16Type of printer. Can be connected to a computer for communication, or alternativelyREX DCThunder magnetic data acquisition software and computer communication
The protection level of the instrument casing isIP65Waterproof and dustproof, suitable for field operations
Produced by our factoryD0-958-BDissolved oxygen electrode (polarographic coated oxygen)
TECHNICAL INDEX
|
model |
JPB-607 |
JPBJ-608 |
JPSJ-605 |
||
|
measure range |
dissolved oxygen |
0~20)mg/L |
(0.00~19.99)mg/L |
(0.00~20.00)mg/L |
|
|
saturation |
|
(0.0~199.9)% |
(0.0~200.0)% |
||
|
temperature |
0~40)℃ |
(0.0~40.0)°C |
(-5.0~105.0)℃ |
||
|
instrument implement base stem or root of plants mistake differ from |
dissolved oxygen |
±0.3mg/L±1One word ±0.5mg/L±1One word(Difference from calibration temperature± |
±0.3mg/L±1One word (at calibrated temperature) ±0.5mg/L±1One word(Difference from calibration temperature± |
±0.3mg/L±1One word±0.5mg/L(Difference from calibration temperature± |
|
|
dissolved oxygen saturation |
|
±5.0%±1One word(At the calibration temperature) ±10.0%±1One word(Difference from calibration temperature± |
±5%(At the calibration temperature) ±10%(Difference from quasi temperature± |
||
|
temperature |
± |
± |
± |
||
|
Residual current |
0.15mg/L |
0.1mg/L |
|||
|
response time |
30s ( |
20s ( |
45s ( |
||
|
Salinity calibration range |
|
(0.0~40.0)g/L |
|||
|
Stability of the instrument |
±0.2mg/L±1One word/1h |
±0.2mg/L/1h |
|||
|
Instrument repeatability |
|
0.2mg/L |
|||
|
Automatic temperature compensation range |
0~40)℃ |
||||
|
Instrument weight |
|
|
|
||
|
External dimensions |
mm:165×72×35 |
mm:210×100×45 |
mm:290×200×70 |
||
|
straight ordinary worker rise strip piece |
ambient temperature |
0~40)℃ |
|||
|
relative humidity |
not more than90% |
Compliant with the protection level of the shellIP65 |
not more than85% |
||
|
Temperature of the tested aqueous solution |
0~40)°C |
||||
|
power supply |
|
4jointAAalkaline battery |
DC power supply(+9V,300mA,Neizheng,External negative) |
||
|
other |
There are no vibrations around that affect performance other than the geomagnetic field |
||||