VIP member
Portable pressure pump
Product features: Various conversion joints can be added; Excellent durability and lightweight;
Product details
Brief introduction
BR-900S handheld pressure pump, also known asPortable pressure pump(hereinafter referred to as pneumatic pump) is a manual pressure pump that can generate positive pressure and vacuum. Its pressure medium is air, and due to the use of valves and joints, it has excellent sealing, durability, and portability. As an indispensable auxiliary equipment for pressure measurement, pneumatic pumps have always been favored by legal professional metrology departments and thermal measurement and control engineering personnel in industrial and mining enterprises.
IIPortable pressure pumpStructural diagram
① ... exhaust valve ②... intake interface (positive pressure, vacuum conversion connection)
③ ④ Interface between standard table and inspected table ⑤ Vacuum conversion interface
⑥ ...... Positive pressure conversion interface ⑦...... Fine tuning knob
⑧ ... air cylinder handle
3、 Technical parameters
Pressure range:- 95~250kPa ;- 0.09~2.5MPa
Volume: 270 × 120 × 65 mm

Set the pressure pump to positive pressure state, that is, connect the positive and negative pressure conversion connection pipe (short quick connection pipe) to the interface ⑥ with "positive pressure", and connect the other end to the intake interface (positive pressure, vacuum conversion connection pipe) ②.
Connect the standard gauge and the tested gauge to interfaces ③ and ④ using connecting pipes (2 long quick connect pipes) to prevent leakage. Place exhaust valve ① in the closed position, then push and pull handle ⑧ to apply pressure. When the pressure reaches the predetermined value, stop pressure creation. At this point, slowly turn the fine adjustment knob ⑦ clockwise to perform pressure adjustment.
When verifying the return error of pressure instruments, slowly rotate the handle of exhaust valve ① counterclockwise. When it approaches the desired pressure value, close exhaust valve ① and use fine-tuning handle ⑦ to perform pressure fine-tuning until all pressure calibration points are calibrated. Open the shut-off valve ① to release air, and return the standard gauge and the inspected gauge to zero.
2. Verify vacuum instruments and meters
Set the pressure pump to vacuum state, that is, connect the positive and negative pressure conversion pipe (short quick connection pipe) to the interface marked with "negative" ⑤, and connect the other end to the intake interface (positive pressure, vacuum conversion pipe) ②. It is the vacuum operation state. At this point, connect the inspected and standard gauge to prevent leakage, place the shut-off valve in the closed position, and then push and pull the handle ⑧ to apply pressure. When the pressure reaches the predetermined value, stop pressure creation. At this point, slowly turn the fine adjustment knob ⑦ clockwise to perform pressure adjustment. Open the shut-off valve ① to release air, and return the standard gauge and the inspected gauge to zero.
5、 Attachment
1. 3 quick connect tubes; (1 short and 2 long)
2. 2 M 20x1.5 internal thread connectors
Special connectors can be processed according to user needs.
BR-900S handheld pressure pump, also known asPortable pressure pump(hereinafter referred to as pneumatic pump) is a manual pressure pump that can generate positive pressure and vacuum. Its pressure medium is air, and due to the use of valves and joints, it has excellent sealing, durability, and portability. As an indispensable auxiliary equipment for pressure measurement, pneumatic pumps have always been favored by legal professional metrology departments and thermal measurement and control engineering personnel in industrial and mining enterprises.
IIPortable pressure pumpStructural diagram

③ ④ Interface between standard table and inspected table ⑤ Vacuum conversion interface
⑥ ...... Positive pressure conversion interface ⑦...... Fine tuning knob
⑧ ... air cylinder handle
3、 Technical parameters
Pressure range:- 95~250kPa ;- 0.09~2.5MPa
Volume: 270 × 120 × 65 mm
Weight: 1.0kg

4、 Usage method
1. Inspect positive pressure instrumentsSet the pressure pump to positive pressure state, that is, connect the positive and negative pressure conversion connection pipe (short quick connection pipe) to the interface ⑥ with "positive pressure", and connect the other end to the intake interface (positive pressure, vacuum conversion connection pipe) ②.
Connect the standard gauge and the tested gauge to interfaces ③ and ④ using connecting pipes (2 long quick connect pipes) to prevent leakage. Place exhaust valve ① in the closed position, then push and pull handle ⑧ to apply pressure. When the pressure reaches the predetermined value, stop pressure creation. At this point, slowly turn the fine adjustment knob ⑦ clockwise to perform pressure adjustment.
When verifying the return error of pressure instruments, slowly rotate the handle of exhaust valve ① counterclockwise. When it approaches the desired pressure value, close exhaust valve ① and use fine-tuning handle ⑦ to perform pressure fine-tuning until all pressure calibration points are calibrated. Open the shut-off valve ① to release air, and return the standard gauge and the inspected gauge to zero.
2. Verify vacuum instruments and meters
Set the pressure pump to vacuum state, that is, connect the positive and negative pressure conversion pipe (short quick connection pipe) to the interface marked with "negative" ⑤, and connect the other end to the intake interface (positive pressure, vacuum conversion pipe) ②. It is the vacuum operation state. At this point, connect the inspected and standard gauge to prevent leakage, place the shut-off valve in the closed position, and then push and pull the handle ⑧ to apply pressure. When the pressure reaches the predetermined value, stop pressure creation. At this point, slowly turn the fine adjustment knob ⑦ clockwise to perform pressure adjustment. Open the shut-off valve ① to release air, and return the standard gauge and the inspected gauge to zero.
5、 Attachment
1. 3 quick connect tubes; (1 short and 2 long)
2. 2 M 20x1.5 internal thread connectors
Special connectors can be processed according to user needs.
Online inquiry