1、 Product selection
|
Product Name |
model |
unit |
configuration |
|
Quilt safety controller |
YM-K380-1 |
set |
380V controls a single cotton quilt to automatically stop in place and limit 4 positions |
|
Quilt safety controller |
YM-K380-2 |
set |
380V controls 2 cotton quilts to automatically stop in place, with 8 limit positions |
|
Quilt safety controller |
YM-K220-1 |
set |
220V control for a single cotton quilt with automatic stop and limit of 4 positions |
|
Quilt safety controller |
YM-K220-2 |
set |
220V controls 2 cotton quilts to automatically stop in place, with 8 limit positions |
|
Wind outlet controller |
YM-FK-1 |
set |
Single air vent controllable24V motor or 220V motor |
|
Wind outlet controller |
YM-FK-2 |
set |
Two controllable air vents24V motor or 220V motor |
|
Quilt safety controller |
YM-K380-1W |
set |
380V control for automatic positioning and stopping of a single cotton quilt, with 4 limit positions, controlled by a mobile app |
|
Quilt safety controller |
YM-K380-2W |
set |
380V controls 2 cotton quilts to automatically stop and limit, with 8 mobile app controls |
|
Quilt safety controller |
YM-K220-1W |
set |
220V control for automatic positioning and stopping of a single cotton quilt, controlled by a mobile app |
|
Quilt safety controller |
YM-K220-2W |
set |
220V controls 2 cotton quilts to automatically stop in place, controlled by mobile app |
|
Wind outlet controller |
YM-FK-G1 |
set |
Single air vent controllable24V motor or 220V motor, controlled by mobile app |
|
Wind outlet controller |
YM-FK-G2 |
set |
Two controllable air vents24V motor or 220V motor, controlled by mobile app |
Note:1. For 220V equipment, it is important to understand the wire system of the customer's motor.
2. Limit switch bracket (optional), rotary encoder (optional)
2、 Functional Features
1. Implement semi automation to prevent human negligence in rolling the cotton quilt over or over.
2. There is an internal time limit function that stops after timeout.
3. There is an internal logic limit function that stops in place or manually stops within the logical range.
4. The device comes with built-in fault detection and alarm functions. When the fault light flashes or there is a buzzing sound
When, it indicates that the device has a malfunction and needs to be initialized.
5. It can be paired with a mobile app to achieve remote control.
4、 Technical parameters
Local Controller
|
model |
YM-K380-1 |
YM-K380-2 |
YM-K220-1 |
YM-K220-2 |
YM-FK-1 |
YM-FK-2 |
|
Control the quantity of equipment |
1 unit |
2 units |
1 unit |
2 units |
1 unit |
2 units |
|
alarm function |
have |
have |
have |
have |
have |
have |
|
Limit function |
have |
have |
have |
have |
have |
have |
|
mobile control |
none |
none |
none |
none |
none |
none |
|
fault diagnosis |
have |
have |
have |
have |
have |
have |
|
input voltage |
380V |
380V |
220V |
220V |
220V |
220V |
|
output voltage |
380V |
380V |
220V |
220V |
220V/24V |
220V/24V |
|
Phase mismatch protector |
have |
have |
none |
none |
none |
none |
|
phase failure protector |
have |
have |
none |
none |
none |
none |
|
button |
have |
have |
have |
have |
have |
have |
|
4G |
none |
none |
none |
none |
none |
none |
|
Work sensor |
have |
have |
have |
have |
have |
have |
|
Power off memory module |
have |
have |
have |
have |
have |
have |
|
overload protection |
have |
have |
have |
have |
have |
have |
wireless controller
|
model |
YM-K380-1W |
YM-K380-2W |
YM-K220-1W |
YM-K220-2W |
YM-FK-G1 |
YM-FK-G2 |
|
Control the quantity of equipment |
1 unit |
2 units |
1 unit |
2 units |
1 unit |
2 units |
|
alarm function |
have |
have |
have |
have |
have |
have |
|
Limit function |
have |
have |
have |
have |
have |
have |
|
mobile control |
have |
have |
have |
have |
have |
have |
|
fault diagnosis |
have |
have |
have |
have |
have |
have |
|
input voltage |
380V |
380V |
220V |
220V |
220V |
220V |
|
output voltage |
380V |
380V |
220V |
220V |
220V/24V |
220V/24V |
|
Phase mismatch protector |
have |
have |
none |
none |
none |
none |
|
phase failure protector |
have |
have |
none |
none |
none |
none |
|
button |
have |
have |
have |
have |
have |
have |
|
4G |
have |
have |
have |
have |
have |
have |
|
Work sensor |
have |
have |
have |
have |
have |
have |
|
Power off memory module |
have |
have |
have |
have |
have |
have |
|
overload protection |
have |
have |
have |
have |
have |
have |
