Guining (Shanghai) Experimental Equipment Co., Ltd
Home>Products>Rosemount Regulating Orifice Flow Meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18016316889
  • Address
    Room 5-823, No. 3688 Tingwei Road, Jinshan District, Shanghai
Contact Now
Rosemount Regulating Orifice Flow Meter
Rosemount orifice flowmeter technology provides * performance with minimal straight pipe requirements. Nowadays, orifice plate measurement technology
Product details

Rosemount orifice flow meters are designed to simplify installation and maximize performance by eliminating the need for impulse piping, special flanges, or pipeline modifications. Self centering mechanism ensures the accuracy of * while improving the entire installation process

The functions of the Rosemount orifice plate include:

  • Reduced the number of straight pipe sections, requiring only twice the diameter of the upstream and downstream pipelines respectively
  • Provide superior performance with up to+/-0.5% accuracy in the installation of shorter straight pipe sections
  • Direct installation function provides * flowmeter solution
  • Compared to traditional orifice plate installation, it can save over 50% of costs
Fully integrated flowmeter


Rosemount 3051SFC_C, Measurement Types 1-4


Rosemount 3051SFC_C, Measurement Type D

accuracy Mass flow rate, reaching 0.8% of mass flow rate, with a range ratio of 14:1
Classic MV type, with a flow rate of ± 0.85% and a flow range ratio of 8:1
• Volume flow rate, reaching 0.8% of the volume flow rate, with a range ratio of 14:1
Classic MV type, achieving a volume flow rate of ± 0.85% and a range ratio of 8:1
repeatability ± 0.1 % ± 0.1 %
output • Based on HART ® 4-20mA signal for communication
Wireless HART with intelligent wireless THUM adapter

• Based on HART ® 4-20mA signal for communication
• WirelessHART
• FOUNDATION ™ Fieldbus

Long term stability Stability for up to 10 years Stability for up to 10 years
warranty 12 year limited warranty 12 year limited warranty
diagnosis • User writable process temperature sensor limitations
Output as sensor temperature
• Instant traffic verification
Advanced HART Diagnostic Kit
Pipeline size 2-in (50 mm)
3-in (80 mm)
4-in (100 mm)
6-in (150 mm)
8-in (200 mm)
10-in (250 mm)
12-in (300 mm)
2-in (50 mm)
3-in (80 mm)
4-in (100 mm)
6-in (150 mm)
8-in (200 mm)
10-in (250 mm)
12-in (300 mm)
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!