Product Usage
This series of water meters is used to measure the amount of cold water flowing through the tap water pipeline for drinking in households or residential units.
Usage conditions
Temperature level: T30
Water pressure level: MAP 10 / MAP 16
Pressure loss level: △ P 63
Indication error limit:
From the low zone including the minimum flow rate (Q1) to excluding the boundary flow rate (Q2) ± 5%
From high zone cold water including boundary flow (Q2) to high zone cold water including overload flow (Q4) ± 2%, hot water ± 3%
main features
Multi flow rate, rotor type, high measurement accuracy, small starting flow rate, easy to read.
Stable and reliable performance, long service life, beautiful appearance, strong universality of water meters, easy replacement and maintenance.
This series of watch cases can be made of copper, iron, stainless steel, engineering plastics, and aluminum alloy composite materials.
The series has strong universality and is easy to replace and repair; Accurate measurement and durability.
technical parameter
caliber | measuring range | Overload flow | Common traffic Q3 | Boundary flow Q2 | Minimum flow Q1 | Start flow rate | Minimum reading | Maximum reading | |
DN | Q3/Q1 | Q4 | |||||||
mm | m3/h | L/h | m3 | ||||||
15 | 80 | 3.125 | 2.5 | 50 | 31.25 | 6 | 0.00005 | 99999 | |
100 | 40 | 25 | |||||||
125 | 32 | 20 | 5 | ||||||
160 | 25 | 15.625 | |||||||
20 | 80 | 5 | 4 | 80 | 50 | 10 | |||
100 | 64 | 40 | |||||||
125 | 51.2 | 32 | 6 | ||||||
160 | 40 | 25 | |||||||
25 | 80 | 7.875 | 6.3 | 126 | 78.78 | 12 | |||
100 | 100.8 | 63 | |||||||
125 | 80.64 | 50.4 | 8 | ||||||
160 | 63 | 39.375 | |||||||
32 | 80 | 12.5 | 10 | 200 | 125 | 14 | |||
100 | 160 | 100 | |||||||
125 | 128 | 80 | 10 | ||||||
160 | 100 | 62.5 | |||||||
40 | 80 | 20 | 16 | 320 | 200 | 40 | |||
100 | 256 | 160 | |||||||
125 | 204.8 | 128 | 35 | ||||||
160 | 160 | 100 | |||||||
50 | 80 | 31.25 | 25 | 500 | 312.5 | 70 | |||
100 | 400 | 250 | |||||||
125 | 320 | 200 | 60 | ||||||
160 | 250 | 156.25 |
Flow error curve

Pressure loss curve

External dimensions and weight
Nominal diameter | Long L | Width B | High H | Connecting thread (D) | Weight (kg) |
(mm) | mm | ||||
15 | 165/190 | 99 | 104 | G3/4B | 1.5/1.6 |
20 | 190/195 | 99 | 106 | G1B | 1.7 |
25 | 260/225 | 104 | 120 | G1 1/4B | 2.6/2.4 |
32 | 260/230 | 104 | 120 | G1 1/2B | 2.8/2.7 |
40 | 300/245 | 125 | 155 | G2B | 5.4/4.5 |
50 | 300 | 125 | 155 | B2 1/2B | 7.2 |
280 | 158 | 175 | Flange connection according to GB4216.4.84 D=165 D1=125 | 14 |

Usage conditions
The working water temperature should not exceed 40oC
Work pressure not exceeding 1MPa