product details
The S500M-01 carbon dioxide transmitter is equipped with a low-power, high-precision microprocessor and utilizes catalytic combustion, electrochemical, and thermal conductivity sensor technologies to convert target gas concentration signals leaked from the air into electrical signals for output. The product has advantages such as stable performance and sensitive response. The transmitter outputs electrical signals using 4-20mA analog signals or RS485 digital communication methods, which can be directly uploaded to monitoring equipment such as DCS, GDS, PLC, etc. The output signal of the transmitter has the advantages of high accuracy and long transmission distance. The transmitter can also be used independently and has passive switch output for on-site control of other devices.
Technical Parameter
Product features:
◆ Built in top-level brand sensors, with sensitive response and long lifespan;
◆ Compatible with sensors based on different principles such as catalysis, electrochemistry, semiconductor, and infrared, with powerful functions;
◆ Built in low-power, high-precision microprocessor, small zero drift, high accuracy;
◆ Optional high-quality LCD display screen, allowing for direct viewing of data on-site;
Standard 4-20mA RS485、 Switching signal output, can be uploaded to PLC/DCS/GDS, etc;
Detect gas |
carbon dioxide |
measuring range |
0-2000ppm |
Optional range |
0-5000-5%VOL-10%VOL |
Resolution |
1PPM/0.1PPM |
detection |
Natural diffusion |
Detection Principle |
Catalytic combustion, electrochemistry, semiconductor, infrared, etc; |
response time |
<15s |
work environment |
Temperature:- 20℃-60℃ |
Working humidity |
15-90% RH without condensation |
Working pressure |
90~110Kpa |
working voltage |
DC24V |
output signal |
4-20mA (three wire), RS485 (four wire system), switch quantity |
Other measurable gases:
Tested gas |
measuring range |
Optional range |
response time |
Carbon monoxide CO |
0-1000ppm |
0-500/2000/5000ppm |
≤ 15 seconds |
Oxygen O2 |
0-30%VOL |
0-25%VOL |
≤ 15 seconds |
sulfur dioxide |
0-20ppm |
0-50, 1000ppm |
≤ 20 seconds |
methane |
0-100%LEL |
0-100%VOL |
≤ 15 seconds |
Hydrogen sulfide H2S |
0-100ppm |
0-50, 200, 1000ppm |
≤ 15 seconds |
Ammonia NH3 |
0-100ppm |
0-50, 500, 1000ppm |
≤ 20 seconds |
Carbon dioxide CO2 |
0-2000ppm |
0-5000-5%VOL-10%VOL |
≤ 20 seconds |
Nitrogen dioxide NO2 |
0-20ppm |
0-2000ppm |
≤ 20 seconds |
Hydrogen H2 |
0-1000ppm |
0-40000ppm |
≤ 20 seconds |
Phosphine PH3 |
0-20ppm |
0-2000PPM |
≤ 20 seconds |
Ozone O3 |
0-10ppm |
0-100ppm |
≤ 20 seconds |
Organic TVOC |
0-60000ppb |
/ |
≤ 20 seconds |
formaldehyde |
0-10ppm |
0-20ppm |
≤ 20 seconds |
Please contact the company for unlisted gases |