■Product Overview:
SEM9880Online monitoring instrument for oil in waterIt is a new generation fully automatic online analyzer for oil in water. This product is a maintenance free online monitoring instrument launched by Shanghai Yizhan Environmental Protection Technology Co., Ltd. based on years of research on water quality analysis products. After passing through the pre-treatment device, the water sample and indicator are separately sent to the colorimetric cell and then irradiated with ultraviolet light to produce ultraviolet absorption. The instrument can directly measure the oil value in the water sample through photoelectric colorimetry.
■Measurement principle:
The online analyzer for oil (hydrocarbons) in water is designed specifically for measuring the concentration of oil (hydrocarbons) in water. The instrument uses ultraviolet fluorescence method to measure the concentration of oil molecules in water. Oil molecules are activated into an excited state under specific ultraviolet light irradiation, which is very unstable and quickly returns to the ground state; During the process of returning to the ground state, radiation fluorescence is generated, and the concentration of oil molecules in the water sample is directly proportional to the intensity of the emitted radiation fluorescence. The water sample is sent to the colorimetric cell after passing through the pre-treatment device, and the light source is parallel to the oil molecules in the colorimetric cell. The generated fluorescence is irradiated on the fluorescence sensor, and a precise filtering system is installed before the ultraviolet light emission and fluorescence sensor reception to control the emission wavelength of ultraviolet light and select the specific fluorescence wavelength that receives the scattered oil molecules. The received fluorescence intensity corresponds to the concentration of oil in the water sample to a certain extent. After the selection and control of the emission and reception wavelengths by the filtering system, this linear relationship can be made more clear.
■SEM9880Online monitoring instrument for oil in waterPerformance and features:
Advanced UV fluorescence measurement technology ensures stable and reliable online monitoring results
The water sample pretreatment device adopts a maintenance free design, which can ensure that the maintenance cycle of the pretreatment device exceeds six months
*Non contact sampling eliminates contamination of the sampling device by water samples, greatly extending the service life of the instrument
Intelligent data processing can automatically eliminate abnormal and sudden values caused by instrument failures, making measurement data more accurate
The overall structure of the instrument is easy for users to maintain and suitable for working in harsh conditions
◎ Diversified online monitoring methods, which can realize manual measurement at any time, automatic timed measurement, automatic periodic measurement and other measurement methods
◎ The data transmission has multiple signal outputs such as RS232, RS485, and 20mA, which intuitively display the oil concentration mg/L value
◎ No pollution, truly environmentally friendly
◎ Automatic and manual multi-point calibration, convenient for users to set flexible automatic calibration operations according to different water sample settings
■Technical parameters:
Measurement range: 0-10/50/100/200ppm (customizable)
◎ Measurement method: UV method
◎ Measurement lower limit: 0.05ppm
Accuracy: ± 5%
◎ Repeatability: ± 5%
◎ Response time: 10 seconds
◎ Testing methods: timed, equidistant, manual
◎ Maintenance method: Self maintenance, user maintenance interval>5 months
◎ Self monitoring: Instrument status self diagnosis
◎ Analog output: 4-20mA analog output
◎ Relay control: 2-channel 24V 1A relay high and low point control
◎ Data transmission method: RS232,RS485
◎ Display: 8.0-inch large LCD touch screen with a resolution of 800 × 600
◎ Data storage: one year of valid data
◎ Working temperature:+ 0~40°C
◎ Power supply: 220 ± 10% VAC; 50-60Hz
◎ Power consumption: approximately 100 VA
◎ Size: 500mm × 1650mm × 320mm
Weight: Approximately 70Kg
■Practical application:
Surface water environment monitoring of rivers and lakes
◎ Marine water quality and environmental monitoring
◎ Monitoring of sewage discharge from ships and vessels
◎ Industrial wastewater discharge and municipal wastewater inlet monitoring
◎ Petrochemical wastewater discharge monitoring
◎ Monitoring of steam boiler condensate water recovery system
◎ Monitoring of cooling water circulation system
◎ Entrance monitoring of seawater desalination plant
◎ Water quality monitoring of oilfield oil recovery reinjection water
◎ Oil content monitoring of drinking water and purified water
System alarm and fault handling:
When the system encounters an alarm, the instrument stops running and maintains the process and state of the instrument alarm, and displays the specific alarm content in the lower left corner of the instrument LCD screen interface. Relevant personnel should analyze the causes of the alarm and take corresponding measures according to the handling methods provided in the table below. After processing, please select 'System Pause' for functional testing before continuing with instrument calibration and measurement.
call the police | reason | measure |
Take water samples call the police | Preprocessing is not enabled; The water sample is too dirty and blocks the water sample tube or the solenoid valve of the water sample tube; The piston or pipeline interface is leaking air. | Check whether the pre-treatment is turned on and whether the water sample tube is connected to the water sample container during pre-treatment when measuring the water sample; When taking a water sample with the piston upwards, use an ear wash ball to blow the water sample tube and check if it is blocked; Unscrew the interface between the infusion pump and the quantitative tube, use an ear wash ball to blow and check the sealing quality. |
Take standard samples2 call the police | Standard solution2There is no standard solution in the reagent bottle2Solution; Take standard solution2 The pipeline and standard solution2The liquid level has left; Standard solution2 The solenoid valve cannot be opened; The piston or pipeline interface is leaking air. | View standard solution2Is there a solution in the reagent bottle or is the injection tube detached from the liquid; When the piston is moving towards the sampling solution2Use an ear wash ball to blow the label solution2Tube, check the standard solution2Is the solenoid valve open or blocked; Unscrew the interface between the infusion pump and the quantitative tube, use an ear wash ball to blow and check the sealing quality. |
Retrieve reagentsA call the police | reagentAThere are no reagents in the bottleASolution; Injection pipeline and reagentsAThe liquid level has left; reagentAThe solenoid valve cannot be opened or the pipeline is blocked; The piston or pipeline interface is leaking air. | View reagentsAIs there any solution in the bottle or is the injection tube detached from the liquid; When the piston lifts the reagent upwardsAWhen using an ear wash ball to blow the reagentATube, check reagentsAIs the solenoid valve open or blocked; Unscrew the interface between the infusion pump and the quantitative tube, use an ear wash ball to blow and check the sealing quality. |
Retrieve reagentsB call the police | reagentBThere are no reagents in the bottleBSolution; The injection pipeline is separated from the liquid level of reagent B; reagentBThe solenoid valve cannot be opened or the pipeline is blocked; The piston or pipeline interface is leaking air. | View reagentsBIs there any solution in the bottle or is the injection tube detached from the liquid; When the piston is lifted to take reagent B, use an ear wash ball to blow the reagentBCheck if the solenoid valve of reagent B tube is open or blocked; Unscrew the interface between the infusion pump and the quantitative tube, use an ear wash ball to blow and check the sealing quality. |
Positioning alarm | Pollution on the pipe wall | Put the standard solution2Insert the sample tube into distilled water and repeat the cleaning of the quantitative tube using the cleaning function in the functional test until the signal of the high-low photometer returns to normal. |
Heating alarm | The sensor probe is exposed at the sensor placement position of the reaction tank; Poor connection between sensor and circuit board; The sensor is damaged; The heating wire is damaged. | Check the probe of the temperature sensor and its connection to the circuit board; Extract from the reactor1mLStandard solution2Select heating in the functional test and observe whether the heating device can work properly. If it can be heated normally, please choose to cool down or pause the system to stop heating and ensure maintenance safety. |