Shanghai Fuzhan Environmental Protection Technology Co., Ltd
Home>Products>SNC100-SW acid mist gas detector
SNC100-SW acid mist gas detector
The SNC100-SW acid mist gas detector is a fixed, liquid crystal display type volatile organic compound gas detector independently developed and design
Product details

Detailed information of SNC100-SW acid mist gas detector:

Fixed acid mist gas detector

SNC100-SW

SNC100-SW acid mist gas detectorProduct Introduction

SNC100-SW acid mist gas detectorcorrectFu ZhanWith over ten years of technical experience in electronic applications, we have independently developed and designed a fixed, liquid crystal display volatile organic compound gas detector specifically for acid mist generation in chemical, electronic, metallurgical, electroplating, textile, machinery manufacturing, forklift rooms, battery workshops, and other places. The signal defaults to 4-20mA current output. The product utilizes advanced microelectronic processing technology and is equipped with imported gas sensors from abroad, which can quickly and accurately detect target gases. The product is designed with the highest level of three defenses for the gas detection industry: anti high concentration overload (with self-protection function), anti personnel misoperation (built-in buttons+can restore factory settings), and lightning protection (third level standard). Inherent safety circuit design, equipped with an aluminum alloy explosion-proof shell, can be safely used even in harsh environments.

SNC100-SW acid mist gas detectorIt is a gas diffusion type. The detection principle is that when the target gas enters the gas probe section, the internal sensor will emit a sense of time. Sensors generate certain electrical signals based on the concentration of gas. After being amplified by the circuit, the signal is processed by the CPU through AD sampling, temperature compensation, and intelligent calculation to output accurate 4-20mA current signals, RS485 communication signals, 0-5V voltage signals, ZIGBEE, NRF, WIFI, GPRS wireless signals, etc. Customers can collect these signals andFu ZhanThe company'sBNC-800ABNC-800BBNC-800C gas alarm control host PLC、DCS、 The upper computer and other systems are used in conjunction for alarm and data reprocessing. In addition, the product is equipped with 2 sets of relays (switch signals) inside, which can be linked with the control equipment of the fan and solenoid valve to maximize the protection of your life and property safety.

SNC100-SW acid mist gas detectorAccording to customer needs, optional sound and light alarms, infrared remote controls, pipeline type air cups, pump suction air cups, etc. can also be selected.

SNC100-SW acid mist gas detectorProduct Features

  • Inherent safety circuit design, safe and reliable
  • Large screen LCD display, capable of24Hourly online monitoring, real-time display of gas concentration;
  • Imported gas sensors from overseas with original packaging, fast response speed, low error rate, and strong anti-interference ability;
  • 200 Multiple gases, multiple ranges, and multiple signal outputs to choose from;
  • Powerful sound and light alarm function, sound in85dB above;
  • Customers can set alarm points and other functions according to their needs;
  • Built in buttons+Restore the factory settings function to avoid personnel misoperation;
  • Equipped with full range temperature compensation and data correction functions, it improves the accuracy and stability of the product;
  • 2Group relay (switch signal) signal output, convenient for linkage with control equipment of fans or solenoid valves;
  • The alarm point, zero point adjustment, and target point calibration of the detector can be performed through the remote control without opening the cover;
  • Unique structural design, simple and convenient installation and wiring, saving costs.
  • Aluminum alloy cast explosion-proof shell, ensuring safety and security;
  • Explosion proof certificate level:ExdIICT6 Gb
  • Protection level:IP65

SNC100-SW acid mist gas detectorApplication location

Petroleum and petrochemical plants, chemical plants, smelters, steel plants, coal plants, thermal power plants, water plants, pharmaceutical workshops, tobacco companies, atmospheric environment monitoring, scientific research institutions, building construction, fire alarm, sewage treatment, industrial process control, boiler rooms, garbage treatment plants, underground tunnels, oil pipelines, gas stations, underground pipeline maintenance, indoor air quality testing, food processing, sterilization and disinfection, refrigerated warehouses, pesticide and fertilizer manufacturing, insecticide manufacturing, etc.

SNC100-SW acid mist gas detectorProduct parameters

Detect gas

acid mist

chemical formula

SW

Detection Principle

electrochemistry

Range of measurement

0-5, 10, 20, 50, 100, 200, 500, 1000ppm optional (please consult for more ranges)

resolution

0.01ppm, 0.1ppm, 1ppm (depending on range and sensor)

detection

Diffuse, pipeline, pump suction (optional)

Installation method

Installed against the wall (closest to the gas leak source)

output signal

4-20mA current signal (can also provide voltage output within the range of 0-5V)

Design standards

GB 50493-2009 "Design Specification for Combustible Gas and Toxic Gas Detection and Alarm in Petrochemical Enterprises"

GB 50493-2009 "Design Specification for Combustible Gas and Toxic Gas Detection and Alarm in Petrochemical Enterprises"

GB 12358-2006 General Technical Requirements for Workplace Gas Detection and Alarm Devices

Execution standards

GB3836.1-2010 Electrical Equipment for Explosive Gas Environments Part: General Requirements

GB3836.2-2010 "Electrical equipment for explosive gas atmospheres - Part 2: Explosion proof type" d ""

Q/FUZ 01-2014 "Enterprise Execution Standards"

Level

Industrial grade

Display mode

liquid crystal display

working voltage

DC 12-30V

Shell material

Aluminum alloy casting body

Precision

≤±3%

audible and visual alarm

LED light+≥ 85dB (optional)

response time

≤30S(T90)

relay

2 sets (1A/24VDC) (optional)

repeatability

≤±2%

Explosion proof grade

ExdⅡCT6 Gb

zero drift

≤± 1% (F.S/year)

protection grade

IP65

operation temperature

-20℃~+50℃

Measurement certificate

optional

Working humidity

≤ 95% RH without condensation

Line system

Two wire or three wire system is optional (split line type)

Working pressure

86~106Kpa

Fixed position

2 locations

power waste

≤1.5W (24V DC)

Inlet

M20*1.5

Dimensions

168mm×140mm×93mm

outlet

M20*1.5

Coverage radius

≤ 7.5 meters

life

2-5 years (depending on the sensor)

Weight

About 1.5Kg