Chongqing Sainz Instrument Co., Ltd
Home>Products>SS705 online multi parameter water quality monitoring instrument
SS705 online multi parameter water quality monitoring instrument
SS705 online multi parameter water quality monitoring instrument is suitable for environmental protection, agriculture, manufacturing, education, scie
Product details

Online multi parameter water quality monitoring instrumentTechnical parameters

1. temperatureMeasurement range: (-10.0~120.0) ℃

Basic error of electronic unit: ± 0.3 ℃ ± 1 word

Basic instrument error: ± 0.5 ℃± 1 word (0.0 ℃≤ T ≤ 60.0 ℃);

Other range ± 1.0 ℃ ± 1 word

2. PHMeasurement range: (0.00~14.00)pH

Basic error of electronic unit: ± 0.03pH ± 1 word

Basic error of the instrument: ± 0.05pH ± 1 word

3. ORPMeasurement range: (-1999~1999)mV

Basic error of electronic unit: ± 1mV ± 1 word

Basic error of the instrument: ± 10mV ± 1 word

4. Conductivity/TDS

Conductivity measurement range: 0.000 μ S/cm to 0.199 μ S/cm

0.20 μS/cm~1.99 μS/cm

2.0 μS/cm~19.9 μS/cm

20 μS/cm~199 μS/cm

0.2 mS/cm~1.99 mS/cm

2.0 mS/cm~19.9 mS/cm

TDS measurement range: 0.000 mg/L to 0.099 mg/L

0.10 mg/L~0.99 mg/L

1.0 mg/L~9.9 mg/L

10 mg/L~99 mg/L

0.10 g/L~0.99 g/L

1.0 g/L~9.9 g/L

Basic error of electronic unit: ± 1.0% (FS)

Basic instrument error: ± 2.0% (FS)

5. Dissolved oxygen concentration/saturation

Measurement range: Dissolved oxygen concentration: (0.00~20.00)mg/L;

Dissolved oxygen saturation: (0.0~200.0)%

Basic error of electronic unit: dissolved oxygen concentration: ± 0.20mg/L;

Dissolved oxygen saturation: ± 5% (FS).

Basic instrument error: Dissolved oxygen concentration: ± 0.50mg/L when the temperature difference between the calibration water sample and the measured water should not exceed ± 15.0 ℃;

Dissolved oxygen saturation: ± 10.0% when the temperature difference between the calibration water sample and the measured water does not exceed ± 15.0 ℃.

6. Normal working conditions of the instrument:

Environmental temperature: (5.0-35.0) ℃;

Relative humidity: not exceeding 85%;

Power supply: AC voltage (220 ± 22) V;

Frequency (50 ± 1) Hz;

There are vibrations around that do not affect performance;

There are no corrosive gases present in the surrounding air;

Electromagnetic field interference that does not affect performance other than the geomagnetic field in the surrounding area

7. Dimensions: 600mm * 455mm * 720mm

Online multi parameter water quality monitoring instrumentProduct Features

Note: SS705

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!