Second hand Shimadzu GC-2010 gas chromatography-mass spectrometry analyzer
Product Introduction Instrument Introduction Shimadzu GC-2010 is a highly reliable next-generation gas chromatograph product that achieves trace analy
Product details

Instrument Introduction

ShimadzuGC-2010 is a highly reliable next-generation gas chromatograph product that achieves extreme trace analysis and rapid analysis through advanced flow control technology. At the same time, it is very easy to operate, providing efficient separation, qualitative and quantitative functions for the analysis of trace compounds.

Technical Parameter

Adopting electronic flow controllerAFC, It can control the carrier gas with high precision in the fields of rapid analysis, high pressure, and high flow.
column oven
Temperature range; Room temperature ten4℃—450'C(When using liquefied carbon dioxide·:- 50-450℃)
Temperature accuracy; set value(K) ± 1% (able to operate at 0.01 ℃)calibration)
Temperature deviation;2℃within(On a circumference 30mm away from the inner wall and 200mm in diameter)
Correlation of room temperature changes;0.01℃/℃
Number of program segments;20 segments (cooling program available)
Program ratio setting range—250~250℃min
Total program time:~9999.99min
Size: Long280mm x 175mm x 280mm in height
Internal volume:13.7 L
When using liquefied carbon dioxide, additional accessories need to be selected

Sample injection department
Can be loadedUnit 3
Injection unit: Split/No Split Injection Unit
direct(Full volume) injection unit
Column head injection/PTV injection unit

Testing Department
Can be loadedUnit 4. The detector gas adopts APC electronic control
Hydrogen flame ionization detector(FID)
Temperature range:~450℃
Detection quantity:3pgC/s (dodecane)
Dynamic range: To the power of ten or seven
Thermal conductivity detector:(TCD)
Temperature range:~400℃
Sensitivity:20000mv.ml/mg (decane)
Dynamic range:10-4
ECd(ECD)
Temperature range:~350℃
Detection quantity:8fg/s(Y-BHC)
dynamic range: ten-4
flame photometric detector(FPD)
Temperature range:~350℃
Column measurement:P: 0.2 pgP/s (tributyl phosphate): 4pgS/s (dodecanethiol)
dynamic range: The fourth power of P=10-3
FTD(FTD)
Temperature range:~450℃
Detection quantity:N: 03pg N/s (azobenzene)
P: 0.03 pg P/S (malathion)
dynamic range: N、P 10-3

Carrier gas flow control department
Advanced flow controller(AFC)
Split/No Split Method
Pressure setting range:O~970KPa
Number of program segments:7 segments (cooling program available)
Program ratio setting range:- 400~400Kpa/min
Range of diversion ratio setting:0~9999.9
Full flow setting range:O~1200ml/min
Maintain a constant chromatographic column mean line velocity during the heating process of the column temperature chamber

direct(Full volume) injection method
Pressure mode;
Pressure setting range;O~970KPa
Number of program segments:7 paragraphs
Program ratio setting range:-400~400KPa/min
Traffic method:
Flow setting range;O~1200ml/min
Number of program segments;7 paragraphs
Program ratio setting range:—400~400ml/min
The average linear velocity of the chromatographic column can be kept constant during the heating process of the column temperature chamber
sizeweightUsed power supply(GC Host Part)
size: Length 515mm x Width 530mm x Height 440mm Weight 30kg (FID type)
Used power supply: AV220V,1800VA 50/60Hz