Kemu Electronics (Shanghai) Trading Co., Ltd
Home>Products>Semi automatic titrator/mixer APB-610
Semi automatic titrator/mixer APB-610
Kyoto Electronics KEM semi-automatic titrator/dispenser APB-610 is a high-precision burette injection device among similar products. It can perform mu
Product details


Semi automatic titrator/mixer APB-610

The main features of the semi-automatic titrator/mixer APB-610 are:

1. High accuracy and resolution burette injection volume among similar products.
When used alone, it is particularly suitable for manual titration of color judgment.
3. LCD display screen, the injection speed of reagents can be adjusted and set by oneself.
The burette set on the old model APB-510/410 can also be used.
5. In case of liquid leakage caused by operational errors, the instrument has comprehensive protective measures.
6. Various types of reagent bottles available on the market can be directly used.
7. The burette nozzle is made of PTFE material and comes standard with two types: capillary and reverse osmosis.
8. Glass burettes are equipped with protective sleeves, which can avoid light and provide greater safety.

Technical parameters of semi-automatic titrator/mixer APB-610:

Display: LCD display with 2 lines and 16 characters.
Burette volume: Comes standard with a 20mL glass burette set (exchange unit) and can be paired with a 50/10/5/1mL burette set (exchange unit).
50mL burette: Accuracy: ± 0.05mL, repeatability: ± 0.02mL, resolution: 0.0025mL.
20mL burette: Accuracy: ± 0.02mL, repeatability: ± 0.01mL, resolution: 0.001mL. Standard configuration.
10mL burette: Accuracy: ± 0.015mL, repeatability: ± 0.005mL, resolution: 0.0005mL.
5mL burette: Accuracy: ± 0.01mL, repeatability: ± 0.003mL, resolution: 0.00025mL.
1mL burette: Accuracy: ± 0.005mL, repeatability: ± 0.001mL, resolution: 0.00005mL.
Inhalation/excretion rate: about 20 seconds/full volume, 20mL burette: 0.02-60mL/min.
Control mode: manual titration mode (solution preparation+titration), solution preparation mode.
Inhalation/discharge switching: ceramic valve automatically switches.
Reagent contact material: PTFE, Glass, ceramics.
Trial drug bottle: Comes standard with a 1L PP plastic bottle.
Operation mode: keyboard input, equipped with standard remote control buttons.
Input/output connection: Connect the automatic potentiometric titrator and self sampler (S-BUS), RS-232C, and temperature sensor (Pt100).
Blender: A magnetic stirrer (MS-610) that can be purchased externally.
Power supply conditions: AC100V~120V or AC200V~240V, 50/60Hz, 20W.
Size: 120 (W) × 363 (D) × 610 (H) mm.
Weight: Approximately 5 kilograms.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!