Ergonomic handheld design, lightweight and portable with a large LCD screen and navigation menu, making operation easier:LCDDisplay screen size:50×66(Visible area:46×62)mm.
IP67Waterproof and earthquake resistant design, safer to use
exceed1000Hour battery life and600Ten thousand button life, durable and reliable
Rich electrode options to meet different application needs; More4close1Electrode, adapt to constant changes!
Measurement time can be displayed on the user interface——Indicator for electrode health and maintenance schedule.
Two measurement modes: stable measurement or continuous measurement.
5A laminated button, material: protectedPET.
Alkaline battery:3AA×1.5V
WaterproofMP-5andMP-8Connector, suitable for portable electrode use.
MP-5: SupplyPH1, EC5andDO6Type electrode usage: (IP67).
MP-8: SupplyMM110andMM150Type electrode usage: (IP67).
Instrument operation manuals in multiple languages: English, Spanish, French, Portuguese, Chinese.
SensION+PH1portablePHcountProduct model and function:
|
|
pHMeter |
ECMeter |
Dissolved oxygen analyzer |
Multi parameter measuring instrument |
||
PH1 |
EC5 |
DO6 |
MM110 |
MM150 |
MM156 |
||
pH, Temperature&ORP |
pHRange:-2.00-19.00 |
√ |
|
|
√ |
√ |
√ |
ORPRange:±2000mV |
√ |
|
|
√ |
√ |
√ |
|
Temperature range:-20-150℃(-4~302℉) |
√ |
√ |
0-50℃ |
√ |
√ |
√ |
|
Automatic buffer recognition(5Seed buffer solution2.00,4.01,7.00,9.21and10.01) -Manual or default input |
√ |
|
|
√ |
√ |
√ |
|
ORPcalibration |
√ |
|
|
√ |
√ |
√ |
|
EC |
ECRange:0.00-500.0mS/cm(Automatic range selection) |
|
√ |
|
|
√ |
√ |
TDSRange:0-200g/L(Automatic range selection) |
|
√ |
|
|
√ |
√ |
|
Salinity range:0.0-50.0g/L |
|
√ |
|
|
√ |
√ |
|
Can be carried out1,2,3Point conductivity calibration -Standard value:147,1413μS/cm, 12.88, 111.8mS/ cm@25℃ -Manual or default input |
|
√ |
|
|
√ |
√ |
|
Temperature compensation (throughPt1000Automatic compensation of sensors Selectable temperature coefficient(0-9.99%/℃);The reference temperature is20perhaps25℃ |
|
√ |
|
|
√ |
√ |
|
TDSConversion factor (in0-4.44Between options; The default value is0.64) |
|
√ |
|
|
√ |
√ |
|
dissolved oxygen |
Dissolved oxygen range:0.00-19.99, 20.0-26.0mg/L %Saturation range:0.0~199.9,200~260% |
|
|
√ |
|
|
√ |
Temperature compensation (through built-in)NTCPerform automatic compensation) |
|
|
√ |
|
|
√ |
|
Pressure compensation (automatic or manual input) |
|
|
√ |
|
|
√ |
|
Salinity compensation (automatic or manual input) |
|
|
√ |
|
|
√ |
|
Dissolved oxygen calibration (performed in the calibration chamber)1Point or2Point,0perhaps100%Calibration) |
|
|
√ |
|
|
√ |
|
Other features |
Can display measurement time |
√ |
√ |
√ |
√ |
√ |
√ |
Can simultaneously read multiple parameter readings |
|
|
|
√ |
√ |
√ |
|
Measurement mode: stable measurement or continuous measurement |
√ |
√ |
√ |
√ |
√ |
√ |
|
Re adjustment of temperature |
√ |
√ |
√ |
√ |
√ |
|
SensION+PH1portablePHcountOrdering Guide:
SensION+PH1 |
PH/mv,℃ |
Basic type (universal type)pHOn site testing components |
LPV2550T.97.002 |
5050T PHtemperature |
Suitable for general water quality analysis |
Superior (dirty water sample)pHOn site testing components |
LPV2551T.97.002 |
5051T PHtemperature |
Suitable for measuring water samples with high solid content and viscous media |
||
Superior (difficult to measure samples)pHOn site testing components |
LPV2552T.97.002 |
5052T PHtemperature |
Suitable for low ionic strength,colloidal state,Milk and paste like samples |
||
Basic typeORPOn site testing components |
LPV2555.97.0002 |
5055 ORP |
Suitable for chemical waste treatment,Electroplating tank and typical water quality analysis |
||
SensION+MM110Can connect multiple parameter electrodes |
superiorpH&ORPMulti parameter testing component |
LPV2645.97.0002 |
5045 PH ORPtemperature |
Suitable for general water quality analysis |
|
SensION+EC5 |
conductivity,total dissolved solids,salinity,℃ |
Basic conductivity field testing component |
LPV3560.97.0002 |
5060conductivity temperature |
Suitable for general water quality analysis |
Superior on-site conductivity testing components |
LPV3562.97.0002 |
5062conductivity temperature |
Suitable for measuring media that are difficult to measure |
||
SensION+DO6 |
dissolved oxygen,saturation,℃ |
Basic dissolved oxygen on-site testing component |
LPV4551.97.0002 |
5120dissolved oxygen temperature |
Suitable for general water quality analysis |
SensION+MM150 |
PH/mv, conductivity,total dissolved solids,salinity℃ |
superiorpHOn site testing components with multiple conductivity parameters |
LPV4059.97.0002 |
5059pHconductivity temperature |
Suitable for agriculture and general water quality analysis |
superiorpH,conductivity&ORPMulti parameter on-site testing component |
LPV4048.97.0002 |
5048pHconductivityORPtemperature |
Suitable for measurement in sewage treatment and general water quality analysis |
SensION+PH1portablePHcount,Hash China's General Agent, Huilong Huanke's General Agent
24HSales telephone;010-59483667
www.170086.com www.hach-wtw.com