Shanghai HuYueMing Scientific Instrument Co., Ltd
Home>Products>Shanghai 1kg/0.1 electronic balance. 2000g/0.01g
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13818412088
  • Address
    No. 11, Chongjiao Road, Malu, Jiading District, Shanghai
Contact Now
Shanghai 1kg/0.1 electronic balance. 2000g/0.01g
Product technical level The domestic L first SB series digital electronic balance is an intelligent balance composed of high stability sensors and sin
Product details

Product technical level in China

SBThe example digital electronic balance adopts high stability sensors andsingle-chip microcomputerAn intelligent balance composed of components.

It solves the current problemat home and abroadThe problems of constant variation and linearity caused by resistance strain sensors. It has the ability to peel

Self calibration, counting memory, fault display and other functions.This balance measures accurately. Fast and stable. Beautiful appearance. Fully functional.

Suitable for industry. Agriculture. Business. school. Scientific research institutions and other institutions conduct rapid measurements of the mass and quantity of objects.

This product is executedJB5374-91(electronic balanceIndustry standards

Power Supply:220V 50HZ

Open power:3W

Accuracy Level III

Model number1102-20002Examples of series A large number of values110g-2000g

Small reading value(d10mgVerification value(e)100mg

model3001-31001Examples of series A large number of values300g-3000g

Small reading value(d100mgVerification value(e)1g


SBThe series of electronic scales are divided into the following specifications according to different ranges

modelSB

2102

3102

5102

10002

20002

5001

10001

20001

30001

Large scale weighing

210g

310g

510g

1000g

2000g

500g

1000g

2000g

2000g

resolution

0.01g

0.01g

0.01g

0.01g

0.01g

0.1g

0.1g

0.1g

0.1g

Calibration division

10d

10d

10d

10d

10d

10d

10d

10d

10d

tare range

200g

300g

500g

1000g

2000g

500g

1000g

2000g

3000g

calibrating weight

200g

200g

500g

500g

1000g

500g

500g

500g

1000g

Scale platform size

φ110

φ130

volume

195*55*260

power supply

External power supply(AC220V+-10% 50HZ+-1HZDC.9V

Temperature and humidity usage

5-35Degree5085%

Preparation for Operation

1Place the balance in a stable position.On a flat workbench.When the countertop is irregular, you can use a gong knife to adjust the height of the rubber foot gong wire..Avoid shaking the balance.Sunlight exposure..Interference from airflow and strong electromagnetic waves

2Usage and environment: Temperature limit:5-35Temperature fluctuations5/h

Relative humidity:50-80

Second startup

1Turn off the power switch of the balance (press down).Connect the power cord.insert220Velectric supply

2Turn on the power switch.Display in sequence:8.8.8.8.8.8..:: Large weighing value ".’--Among them---The display time depends on the stability of the sensor.Therefore, do not place the balance on a workbench with unstable air vents or environments.Later display0Or "0.00The weighing mode of.

Triple Calibration Balance

1Place the balance in a stable position.On a flat workbench.At the same time, vibration should be avoided.Sunlight exposure..Airflow and strong electromagnetic wave interference.Turn on the power of the balance.Preheat for half an hour before proceeding.Only then will the calibration result of the balance be correct.

2Correction operation

Calibration without adding any object on the weighing plate.Press'CAL)Don't let go of the key.I have made an appointment5Display in seconds "--CAL—“Release your grip.wait a moment.Display the shining "standard weight value" and place the weight with the shining "standard weight value" on the scale pan.Display "----Waiting state.Wait a moment.Display the standard weight value.Then take the weights.Display changes to "0perhaps0.00Calibration completed..If the weighing is still inaccurate after calibration.Repeat the calibration process as described above several times

Four weighing methods

1After stable preheating or calibration during startup.Display weighing mode0perhaps0.00

2Place the object on the weighing plate.It shows the weight of the object

five.Peel weight

1Place the container on the weighing plate.The balance displays the weight of the container

2Press'TARDisplay after pressing the 'Peel' button0perhaps0.00Indicates that the tare weight has been removed

3Place items in containers.It shows the mass of the object being weighed

six.Operation of balance counting

1Enter to set the average state of a single counting object.

Place the container needed for counting on the scale pan.You don't need a container, you don't need to put it in.Press'COUCount "display10Shining brightly.At this moment, place it on the scale pan10An object to be counted and then press'AFFConfirm.The monitor has changed to "------Waiting state.Later.The monitor becomes’10The average operation has been completed.The balance can be used for counting operations

2High requirements for counting.Substances with poor quality and properties of individual objects.When counting, it is better to choose a larger unit of mean.Press'COUCount: Display after "10Shining PressCALCalibration "display can be obtained from"10….50 100…250Change.Choose one of the values.Other operations are the same as six.1the same

3Press to exit the counting operationCOUCount "display……You can exit the counting state later.

Seven overweight alarms

When the weight of an object exceeds the value displayed when turned on(1+0.2)After.Display horizontally "------Indicating that the cumulative weight exceeds the prescribed range.Should be taken for weighing.Otherwise, it will damage the balance

Eight precautions for use

1Before use, power on and preheat according to regulations

2The sum of tare weight and the mass of the object being weighed shall not exceed the range of the weighing capacity

3If the weighing is inaccurate.Use standard weights to calibrate the balance

4If you need to remove the circular scale pan from the balance.Please turn the scale pan clockwise before removing it.Do not forcefully lift the weighing pan upwards to avoid damaging the sensor

5Error message appears.Please refer to the table below

error message

describe

processing method

Bottom line

The heavy object on the balance is biased towards negative

Re calibrate with weights

overbar

Overweight alarm.See Seven Articles

Re calibrate with weights

Err-1

Continuous power on/off caused

Shutdown5Power on in seconds

Err-2

Weighing is unstable

Just wait a moment

Nine piece kit

One electronic balance host.One instruction manual and one credit guarantee card.One certificate of conformity.One weighing pan.One power cord and one fuse (inside the power socket).One set of windproof cover (limited to)0.01Balance scale

Ten standard weights for optional items1only

The relevant content of this manual may change due to product updates.If there are differences from the actual product.Subject to physical condition without prior notice.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!