Product technical level in China
SBThe example digital electronic balance adopts high stability sensors andsingle-chip microcomputerAn intelligent balance composed of components.
It solves the current problemat home and abroadThe problems of constant variation and linearity caused by resistance strain sensors. It has the ability to peel
Self calibration, counting memory, fault display and other functions.This balance measures accurately. Fast and stable. Beautiful appearance. Fully functional.
Suitable for industry. Agriculture. Business. school. Scientific research institutions and other institutions conduct rapid measurements of the mass and quantity of objects.
This product is executedJB5374-91(electronic balance)Industry standards
Power Supply:220V 50HZ |
Open power:3W |
Accuracy Level III |
Model number1102-20002Examples of series A large number of values110g-2000g Small reading value(d)10mgVerification value(e)100mg | ||
model3001-31001Examples of series A large number of values300g-3000g Small reading value(d)100mgVerification value(e)1g |
SBThe series of electronic scales are divided into the following specifications according to different ranges
modelSB |
2102 |
3102 |
5102 |
10002 |
20002 |
5001 |
10001 |
20001 |
30001 |
Large scale weighing |
210g |
310g |
510g |
1000g |
2000g |
500g |
1000g |
2000g |
2000g |
resolution |
0.01g |
0.01g |
0.01g |
0.01g |
0.01g |
0.1g |
0.1g |
0.1g |
0.1g |
Calibration division |
10d |
10d |
10d |
10d |
10d |
10d |
10d |
10d |
10d |
tare range |
200g |
300g |
500g |
1000g |
2000g |
500g |
1000g |
2000g |
3000g |
calibrating weight |
200g |
200g |
500g |
500g |
1000g |
500g |
500g |
500g |
1000g |
Scale platform size |
φ110 |
φ130 |
|||||||
volume |
195*55*260 |
||||||||
power supply |
External power supply(AC220V+-10% 50HZ+-1HZ)DC.9V |
||||||||
Temperature and humidity usage |
5-35Degree50—85% |
Preparation for Operation
1Place the balance in a stable position.On a flat workbench.When the countertop is irregular, you can use a gong knife to adjust the height of the rubber foot gong wire..Avoid shaking the balance.Sunlight exposure..Interference from airflow and strong electromagnetic waves
2Usage and environment: Temperature limit:5℃-35℃Temperature fluctuations5℃/h
Relative humidity:50-80℅
Second startup
1Turn off the power switch of the balance (press down).Connect the power cord.insert220Velectric supply
2Turn on the power switch.Display in sequence:8.8.8.8.8.8..:: Large weighing value ".’--Among them---The display time depends on the stability of the sensor.Therefore, do not place the balance on a workbench with unstable air vents or environments.Later display0Or "0.00The weighing mode of.
Triple Calibration Balance
1Place the balance in a stable position.On a flat workbench.At the same time, vibration should be avoided.Sunlight exposure..Airflow and strong electromagnetic wave interference.Turn on the power of the balance.Preheat for half an hour before proceeding.Only then will the calibration result of the balance be correct.
2Correction operation
Calibration without adding any object on the weighing plate.Press'CAL)Don't let go of the key.I have made an appointment5Display in seconds "--CAL—“Release your grip.wait a moment.Display the shining "standard weight value" and place the weight with the shining "standard weight value" on the scale pan.Display "----Waiting state.Wait a moment.Display the standard weight value.Then take the weights.Display changes to "0perhaps0.00Calibration completed..If the weighing is still inaccurate after calibration.Repeat the calibration process as described above several times
Four weighing methods
1After stable preheating or calibration during startup.Display weighing mode0perhaps0.00"
2Place the object on the weighing plate.It shows the weight of the object
five.Peel weight
1Place the container on the weighing plate.The balance displays the weight of the container
2Press'TARDisplay after pressing the 'Peel' button0perhaps0.00Indicates that the tare weight has been removed
3Place items in containers.It shows the mass of the object being weighed
six.Operation of balance counting
1Enter to set the average state of a single counting object.
Place the container needed for counting on the scale pan.You don't need a container, you don't need to put it in.Press'COUCount "display10Shining brightly.At this moment, place it on the scale pan10An object to be counted and then press'AFFConfirm.The monitor has changed to "------Waiting state.Later.The monitor becomes’10The average operation has been completed.The balance can be used for counting operations
2High requirements for counting.Substances with poor quality and properties of individual objects.When counting, it is better to choose a larger unit of mean.Press'COUCount: Display after "10Shining PressCALCalibration "display can be obtained from"10….50 100…250Change.Choose one of the values.Other operations are the same as six.1the same
3Press to exit the counting operationCOUCount "display……You can exit the counting state later.
Seven overweight alarms
When the weight of an object exceeds the value displayed when turned on(1+0.2℅)After.Display horizontally "------Indicating that the cumulative weight exceeds the prescribed range.Should be taken for weighing.Otherwise, it will damage the balance
Eight precautions for use
1Before use, power on and preheat according to regulations
2The sum of tare weight and the mass of the object being weighed shall not exceed the range of the weighing capacity
3If the weighing is inaccurate.Use standard weights to calibrate the balance
4If you need to remove the circular scale pan from the balance.Please turn the scale pan clockwise before removing it.Do not forcefully lift the weighing pan upwards to avoid damaging the sensor
5Error message appears.Please refer to the table below
error message |
describe |
processing method |
Bottom line |
The heavy object on the balance is biased towards negative |
Re calibrate with weights |
overbar |
Overweight alarm.See Seven Articles |
Re calibrate with weights |
Err-1 |
Continuous power on/off caused |
Shutdown5Power on in seconds |
Err-2 |
Weighing is unstable |
Just wait a moment |
Nine piece kit
One electronic balance host.One instruction manual and one credit guarantee card.One certificate of conformity.One weighing pan.One power cord and one fuse (inside the power socket).One set of windproof cover (limited to)0.01Balance scale
Ten standard weights for optional items1only
The relevant content of this manual may change due to product updates.If there are differences from the actual product.Subject to physical condition without prior notice.