Single needle double board
Single needle double board
Product details

Fully automatic enzyme immunoassay analyzer


1. Fully automated ELISA experiment, including sample allocation, reagent injection, incubation, plate washing, and reading.


2. Sample addition channel: 1 sample addition channel, capable of independent operation in the YZ direction, and the motion of the sample addition arm is precisely positioned through feedback from the encoding disk; Use steel needles for sampling to reduce usage costs.


Patent: "A displacement precise positioning device and a sample arm precise positioning device in an enzyme immunoassay workstation", Patent No.: ZL 2013 2 0143714.9。


3. Detection principle: It has liquid level detection and liquid shortage alarm functions, and the detection principle is capacitive induction liquid level detection principle.


Patent: "An Automatic Sample Adding Mechanism", Patent No.: ZL 2013 2 0140953.9。


4. Precision of sample addition:


Sample pump model, sample volume, precision (CV%), accuracy (%)


1000μl 100μl ≤0.5% ≤1.0%


5. Distribution speed: Sample continuous distribution speed ≤ 20 minutes/96 well plate (1 channel with 1000ul sample needle);


The continuous dispensing speed of reagents is ≤ 3 minutes/96 well plate (1 channel 1000ul sample needle).


6. Micro plate position: Multi functional micro plate position for sample addition and incubation, capable of batch processing 2 96 well microplates simultaneously.


7. Sample position: 1 sample carrier, capable of holding 80 sample test tubes.


8. Reagent positions: 8 reagent carriers, capable of simultaneously loading reagents for 8 projects; The original bottle of the reagent kit is loaded onto the machine, and there is no need to transfer the reagents; Each carrier can hold 3 reagent bottles and 8 quality control or standard samples.


9. Incubation module: 2 incubation modules, capable of incubating 2 microplates simultaneously, and each incubation module can be individually temperature controlled. Temperature control range: room temperature -45 ℃, temperature accuracy reaches ± 0.5 ℃, and temperature fluctuation does not exceed 0.5 ℃.


10. ELISA reader: Built in ELISA reader, 8 measurement channels, no fiber optic components, improving reliability; 8 miniature light sources, low heat dissipation, natural cooling, fanless; Standard dual wavelength: 450nm and 630nm, optional four wavelength: 405nm, 450nm 492 nm and 630 nm; Single and dual wavelength detection; Sensitivity ≥ 0.01, standard deviation ≤ 1%, absorbance within the range of 0.2-1.0, linear bias ± 3%, bias not exceeding ± 2% within the range of 1.0-1.5, coefficient of variation ≤ 1%, channel difference extreme value ≤ 0.03.


Patent: "A ELISA reader", Patent No.: ZL 2013 2 0140799.5。


Multi channel intelligent selection device for filter, patent number: ZL 2013 2 0174783.6。


Fully automatic multi-channel absorbance measuring instrument, patent number: ZL 2013 2 0139011.9。


11. Washing machine: 1 washing machine, 8-channel washing head, 8-needle suction and 8-needle injection; 2 buffer channels, 1 distilled water channel, and 1 waste liquid channel; Monitor the liquid level of the tank using four buoyancy switches; Equipped with two-point suction method and bottom flushing method, with adjustable injection volume in 5 levels.


Patent: "Washing Machine Cleaning Head", Patent No.: ZL 2013 2 0140768.X。


12. The program controls the number of washing rows and cleaning times, and the residual amount of washing is ≤ 2ul/hole.


13. Adopting an integrated design of enzyme-linked immunosorbent assay (ELISA) reader and plate washing machine, the colorimetric and plate washing devices can move freely on all microplate positions without the need for a robotic arm to transport the plates. The structure is compact and the system is simple and reliable.


Patent: "Enzyme linked Plate Washing Mechanism", Patent No.: ZL 2013 2 0140184.2。


14. Software: Windows XP or Windows 7 operating system, capable of connecting with hospital LIS/HIS systems to achieve bidirectional communication; It is possible to customize the testing items for each specimen in the same batch of machine samples, and to achieve double hole rechecking.


Patent: "Multi node Communication Circuit Based on RS232C Standard", Patent No.: ZL 2013 2 0176950.0。


15. Power indicator: Voltage 220VAC ± 10%; Frequency 50/60Hz; Power 400VA.


16. Size and weight:


Bare body: 79 * 61 * 65cm (length * width * height), 76kg;


Instrument packaging box: 92 * 70 * 111cm (length * width * height), 100kg.





Technical parameters of fully automatic enzyme immunoassay analyzer:

1. Fully automated ELISA experiment, including sample allocation, reagent injection, incubation, plate washing, and reading.

2. Sample addition channel: 1 sample addition channel, capable of independent operation in the YZ direction, and the motion of the sample addition arm is precisely positioned through feedback from the encoding disk; Use steel needles for sampling to reduce usage costs.

Patent: "A displacement precise positioning device and a sample arm precise positioning device in an enzyme immunoassay workstation", Patent No.: ZL 2013 2 0143714.9。

3. Detection principle: It has liquid level detection and liquid shortage alarm functions, and the detection principle is capacitive induction liquid level detection principle.

Patent: "An Automatic Sample Adding Mechanism", Patent No.: ZL 2013 2 0140953.9。

4. Precision of sample addition:

Sample pump model, sample volume, precision (CV%), accuracy (%)

1000μl 100μl ≤0.5% ≤1.0%

5. Distribution speed: Sample continuous distribution speed ≤ 20 minutes/96 well plate (1 channel with 1000ul sample needle);

The continuous dispensing speed of reagents is ≤ 3 minutes/96 well plate (1 channel 1000ul sample needle).

6. Micro plate position: Multi functional micro plate position for sample addition and incubation, capable of batch processing 2 96 well microplates simultaneously.

7. Sample position: 1 sample carrier, capable of holding 80 sample test tubes.

8. Reagent positions: 8 reagent carriers, capable of simultaneously loading reagents for 8 projects; The original bottle of the reagent kit is loaded onto the machine, and there is no need to transfer the reagents; Each carrier can hold 3 reagent bottles and 8 quality control or standard samples.

9. Incubation module: 2 incubation modules, capable of incubating 2 microplates simultaneously, and each incubation module can be individually temperature controlled. Temperature control range: room temperature -45 ℃, temperature accuracy reaches ± 0.5 ℃, and temperature fluctuation does not exceed 0.5 ℃.

10. ELISA reader: Built in ELISA reader, 8 measurement channels, no fiber optic components, improving reliability; 8 miniature light sources, low heat dissipation, natural cooling, fanless; Standard dual wavelength: 450nm and 630nm, optional four wavelength: 405nm, 450nm 492 nm and 630 nm; Single and dual wavelength detection; Sensitivity ≥ 0.01, standard deviation ≤ 1%, absorbance within the range of 0.2-1.0, linear bias ± 3%, bias not exceeding ± 2% within the range of 1.0-1.5, coefficient of variation ≤ 1%, channel difference extreme value ≤ 0.03.

Patent: "A ELISA reader", Patent No.: ZL 2013 2 0140799.5。

Multi channel intelligent selection device for filter, patent number: ZL 2013 2 0174783.6。

Fully automatic multi-channel absorbance measuring instrument, patent number: ZL 2013 2 0139011.9。

11. Washing machine: 1 washing machine, 8-channel washing head, 8-needle suction and 8-needle injection; 2 buffer channels, 1 distilled water channel, and 1 waste liquid channel; Monitor the liquid level of the tank using four buoyancy switches; Equipped with two-point suction method and bottom flushing method, with adjustable injection volume in 5 levels.

Patent: "Washing Machine Cleaning Head", Patent No.: ZL 2013 2 0140768.X。

12. The program controls the number of washing rows and cleaning times, and the residual amount of washing is ≤ 2ul/hole.

13. Adopting an integrated design of enzyme-linked immunosorbent assay (ELISA) reader and plate washing machine, the colorimetric and plate washing devices can move freely on all microplate positions without the need for a robotic arm to transport the plates. The structure is compact and the system is simple and reliable.

Patent: "Enzyme linked Plate Washing Mechanism", Patent No.: ZL 2013 2 0140184.2。

14. Software: Windows XP or Windows 7 operating system, capable of connecting with hospital LIS/HIS systems to achieve bidirectional communication; It is possible to customize the testing items for each specimen in the same batch of machine samples, and to achieve double hole rechecking.

Patent: "Multi node Communication Circuit Based on RS232C Standard", Patent No.: ZL 2013 2 0176950.0。

15. Power indicator: Voltage 220VAC ± 10%; Frequency 50/60Hz; Power 400VA.

16. Size and weight:

Bare body: 79 * 61 * 65cm (length * width * height), 76kg;

Instrument packaging box: 92 * 70 * 111cm (length * width * height), 100kg.